2,791 research outputs found

    A clinical trial of the Examen and mindfulness within a secular substance use disorder treatment program

    Get PDF
    The Examen is a 500-year-old Jesuit introspective prayer and reflection. Recent research has indicated that it has utility in psychotherapy. This study implemented the Examen as a secular cognitive–behavioral tool in the first longitudinal clinical trial of the intervention with an addiction treatment population, comparing it directly to a treatment-as-usual mindfulness intervention. The study found that Examen and mindfulness are equivalent in outcomes on depression, anxiety, stress, and substance craving. Further research should continue to investigate the Examen as an alternative to mindfulness for religious and secular populations and the factors responsible for the success of these practices

    DYNAMICS OF FISCAL FINANCING IN THE UNITED STATES

    Get PDF
    Dynamic stochastic general equilibrium models that include policy rules for government spending, lump-sum transfers, and distortionary taxation on labor and capital income and on consumption expenditures are fit to U.S. data under a variety of specifica- tions of fiscal policy rules. We obtain several results. First, the best fitting model allows a rich set of fiscal instruments to respond to stabilize debt. Second, responses of aggregate variables to fiscal policy shocks under rich fiscal rules can vary considerably from responses that allow only non-distortionary fiscal instruments to finance debt. Third, based on esti- mated policy rules, transfers, capital tax rates, and government spending have historically responded strongly to government debt, while labor taxes have responded more weakly. Fourth, all components of the intertemporal condition linking debt to expected discounted surpluses—transfers, spending, tax revenues, and discount factors—display instances where their expected movements are important in establishing equilibrium. Fifth, debt-financed fiscal shocks trigger long lasting dynamics so that short-run multipliers can differ markedly from long-run multipliers, even in their signs.

    Dynamics of Fiscal Financing in the United States

    Get PDF
    Dynamic stochastic general equilibrium models that include policy rules for government spending, lump-sum transfers, and distortionary taxation on labor and capital income and on consumption expenditures are fit to U.S. data under a variety of specifications of fiscal policy rules. We obtain several results. First, the best fitting model allows a rich set of fiscal instruments to respond to stabilize debt. Second, responses of aggregate variables to fiscal policy shocks under rich fiscal rules can vary considerably from responses that allow only non-distortionary fiscal instruments to finance debt. Third, based on estimated policy rules, transfers, capital tax rates, and government spending have historically responded strongly to government debt, while labor taxes have responded more weakly. Fourth, all components of the intertemporal condition linking debt to expected discounted surpluses---transfers, spending, tax revenues, and discount factors---display instances where their expected movements are important in establishing equilibrium. Fifth, debt-financed fiscal shocks trigger long lasting dynamics so that short-run multipliers can differ markedly from long-run multipliers, even in their signs.

    New Measurement of the Relative Scintillation Efficiency of Xenon Nuclear Recoils Below 10 keV

    Full text link
    Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative scintillation efficiency of nuclear recoils below 20 keV lead to inconsistent extrapolations at lower energies. This results in a different energy scale and thus sensitivity reach of liquid xenon dark matter detectors. We report a new measurement of the relative scintillation efficiency below 10 keV performed with a liquid xenon scintillation detector, optimized for maximum light collection. Greater than 95% of the interior surface of this detector was instrumented with photomultiplier tubes, giving a scintillation yield of 19.6 photoelectrons/keV electron equivalent for 122 keV gamma rays. We find that the relative scintillation efficiency for nuclear recoils of 5 keV is 0.14, staying constant around this value up to 10 keV. For higher energy recoils we measure a value around 20%, consistent with previously reported data. In light of this new measurement, the XENON10 experiment's results on spin-independent WIMP-nucleon cross section, which were calculated assuming a constant 0.19 relative scintillation efficiency, change from 8.8×10448.8\times10^{-44} cm2^2 to 9.9×10449.9\times10^{-44} cm2^2 for WIMPs of mass 100 GeV/c2^2, and from 4.4×10444.4\times10^{-44} cm2^2 to 5.6×10445.6\times10^{-44} cm2^2 for WIMPs of mass 30 GeV/c2^2.Comment: 8 pages, 8 figure
    corecore