9 research outputs found

    The risk stratification of adverse neonatal outcomes in women with gestational diabetes (STRONG) study

    Get PDF
    Aims: To assess the risk of adverse neonatal outcomes in women with gestational diabetes (GDM) by identifying subgroups of women at higher risk to recognize the characteristics most associated with an excess of risk. Methods: Observational, retrospective, multicenter study involving consecutive women with GDM. To identify distinct and homogeneous subgroups of women at a higher risk, the RECursive Partitioning and AMalgamation (RECPAM) method was used. Overall, 2736 pregnancies complicated by GDM were analyzed. The main outcome measure was the occurrence of adverse neonatal outcomes in pregnancies complicated by GDM. Results: Among study participants (median age 36.8 years, pre-gestational BMI 24.8 kg/m2), six miscarriages, one neonatal death, but no maternal death was recorded. The occurrence of the cumulative adverse outcome (OR 2.48, 95% CI 1.59–3.87), large for gestational age (OR 3.99, 95% CI 2.40–6.63), fetal malformation (OR 2.66, 95% CI 1.00–7.18), and respiratory distress (OR 4.33, 95% CI 1.33–14.12) was associated with previous macrosomia. Large for gestational age was also associated with obesity (OR 1.46, 95% CI 1.00–2.15). Small for gestational age was associated with first trimester glucose levels (OR 1.96, 95% CI 1.04–3.69). Neonatal hypoglycemia was associated with overweight (OR 1.52, 95% CI 1.02–2.27) and obesity (OR 1.62, 95% CI 1.04–2.51). The RECPAM analysis identified high-risk subgroups mainly characterized by high pre-pregnancy BMI (OR 1.68, 95% CI 1.21–2.33 for obese; OR 1.38 95% CI 1.03–1.87 for overweight). Conclusions: A deep investigation on the factors associated with adverse neonatal outcomes requires a risk stratification. In particular, great attention must be paid to the prevention and treatment of obesity

    Correction to: Screening of postpartum diabetes in women with gestational diabetes: high‑risk subgroups and areas for improvements—the STRONG observational study (Acta Diabetologica, (2021), 58, 9, (1187-1197), 10.1007/s00592-021-01707-9)

    No full text
    Authors would like to correct the error in their publication. Figure 3 contains a part in Italian language which is now removed. The collaborator author names were tagged only in the author group but missed to process in Acknowledgements section. The collaborator author names now updated as Study group in the Acknowledgements section. The original article has been corrected

    Subcutaneous insulin infusion (CSII) in italy: The third national survey

    No full text
    Continuous subcutaneous insulin infusion (CSII) is increasingly being used worldwide, mostly thanks to technical improvements. This study examined the current status of CSII in Italy. Physicians in charge of 272 diabetes centers caring for patients using CSII were sent a questionnaire investigating clinical features, pump technology and management of these patients; a large proportion (217 centers, 79.8%) joined the study. By end-April 2013, data had been collected on 10152 patients treated with CSII; 98.2% had type 1 diabetes, 82.4% were adults, 57% female. Only just over half the centers (59%) managed more than 20 CSII patients each. The distribution of patients varied widely both among and within different regions. The main indication for CSII was the de- sire to improve glycemic control. Dropouts (8.65%) were mainly due to difficulties with pump wearability or non-optimal glycemic control. Among CSII patients 61% used a traditional pump, 39% a sensor augmented pump. Only 68% used the CSII advanced functions and glucose sensors were used twelve days per month on average. Round-the-clock assistance was guaranteed in 81% of centers; a full diabetes team followed patients in only 40% of adult-care centers and 50% of pediatric units. CSII is increasingly used in Italy, by adults and pediatric patients. However, further work is needed to unify treatment strategies throughout the country and to encourage optimal pump use and applications

    La terapia insulinica sottocutanea continua (CSII) in Italia. Terza indagine nazionale

    No full text
    Continuous subcutaneous insulin infusion (CSII) is increasingly being used worldwide, mostly thanks to technical improvements. This study examined the current status of CSII in Italy. Physicians in charge of 272 diabetes centers caring for patients using CSII were sent a questionnaire investigating clinical features, pump technology and management of these patients; a large proportion (217 centers, 79.8%) joined the study. By end-April 2013, data had been collected on 10152 patients treated with CSII; 98.2% had type 1 diabetes, 82.4% were adults, 57% female. Only just over half the centers (59%) managed more than 20 CSII patients each. The distribution of patients varied widely both among and within different regions. The main indication for CSII was the de- sire to improve glycemic control. Dropouts (8.65%) were mainly due to difficulties with pump wearability or non-optimal glycemic control. Among CSII patients 61% used a traditional pump, 39% a sensor augmented pump. Only 68% used the CSII advanced functions and glucose sensors were used twelve days per month on average. Round-the-clock assistance was guaranteed in 81% of centers; a full diabetes team followed patients in only 40% of adult-care centers and 50% of pediatric units. CSII is increasingly used in Italy, by adults and pediatric patients. However, further work is needed to unify treatment strategies throughout the country and to encourage optimal pump use and applications

    La terapia insulinica sottocutanea continua (CSII) in Italia. Terza indagine nazionale

    No full text
    Continuous subcutaneous insulin infusion (CSII) is increasingly being used worldwide, mostly thanks to technical improvements. This study examined the current status of CSII in Italy. Physicians in charge of 272 diabetes centers caring for patients using CSII were sent a questionnaire investigating clinical features, pump technology and management of these patients; a large proportion (217 centers, 79.8%) joined the study. By end-April 2013, data had been collected on 10152 patients treated with CSII; 98.2% had type 1 diabetes, 82.4% were adults, 57% female. Only just over half the centers (59%) managed more than 20 CSII patients each. The distribution of patients varied widely both among and within different regions. The main indication for CSII was the de- sire to improve glycemic control. Dropouts (8.65%) were mainly due to difficulties with pump wearability or non-optimal glycemic control. Among CSII patients 61% used a traditional pump, 39% a sensor augmented pump. Only 68% used the CSII advanced functions and glucose sensors were used twelve days per month on average. Round-the-clock assistance was guaranteed in 81% of centers; a full diabetes team followed patients in only 40% of adult-care centers and 50% of pediatric units. CSII is increasingly used in Italy, by adults and pediatric patients. However, further work is needed to unify treatment strategies throughout the country and to encourage optimal pump use and applications

    Continuous subcutaneous insulin infusion in Italy: third national survey.

    No full text
    BACKGROUND: Continuous subcutaneous insulin infusion (CSII) is increasing worldwide, mostly because of improved technology. The aim of this study was to evaluate the current status of CSII in Italy. MATERIALS AND METHODS: Physicians from 272 diabetes centers received a questionnaire investigating clinical features, pump technology, and management of patients on CSII. RESULTS: Two hundred seventeen centers (79.8%) joined the study and, by the end of April 2013, gave information about 10,152 patients treated with CSII: 98.2% with type 1 diabetes mellitus, 81.4% adults, 57% female, and 61% with a conventional pump versus 39% with a sensor-augmented pump. CSII advanced functions were used by 68% of patients, and glucose sensors were used 12 days per month on average. Fifty-eight percent of diabetes centers had more than 20 patients on CSII, but there were differences among centers and among regions. The main indication for CSII was poor glucose control. Dropout was mainly due to pump wearability or nonoptimal glycemic control. Twenty-four hour assistance was guaranteed in 81% of centers. A full diabetes team (physician+nurse+dietician+psychologist) was available in 23% of adult-care diabetes centers and in 53% of pediatric diabetes units. CONCLUSIONS: CSII keeps increasing in Italy. More work is needed to ensure uniform treatment strategies throughout the country and to improve pump use

    Continuous subcutaneous insulin infusion in Italy: Third National Survey

    No full text
    Background: Continuous subcutaneous insulin infusion (CSII) is increasing worldwide, mostly because of improved technology. The aim of this study was to evaluate the current status of CSII in Italy. Materials and Methods: Physicians from 272 diabetes centers received a questionnaire investigating clinical features, pump technology, and management of patients on CSII. Results: Two hundred seventeen centers (79.8%) joined the study and, by the end of April 2013, gave information about 10,152 patients treated with CSII: 98.2% with type 1 diabetes mellitus, 81.4% adults, 57% female, and 61% with a conventional pump versus 39% with a sensor-augmented pump. CSII advanced functions were used by 68% of patients, and glucose sensors were used 12 days per month on average. Fifty-eight percent of diabetes centers had more than 20 patients on CSII, but there were differences among centers and among regions. The main indication for CSII was poor glucose control. Dropout was mainly due to pump wearability or nonoptimal glycemic control. Twenty-four hour assistance was guaranteed in 81% of centers. A full diabetes team (physician+nurse+dietician+psychologist) was available in 23% of adult-care diabetes centers and in 53% of pediatric diabetes units. Conclusions: CSII keeps increasing in Italy. More work is needed to ensure uniform treatment strategies throughout the country and to improve pump use
    corecore