789 research outputs found

    A study on range gated temporal reference acoustical holography Final technical report

    Get PDF
    Acoustical holographic imaging techniques for noninvasive visualization of soft tissue structures in ma

    Measurement of the Charge Collection Efficiency after Heavy Non-Uniform Irradiation in BaBar Silicon Detectors

    Full text link
    We have investigated the depletion voltage changes, the leakage current increase and the charge collection efficiency of a silicon microstrip detector identical to those used in the inner layers of the BaBar Silicon Vertex Tracker (SVT) after heavy non-uniform irradiation. A full SVT module with the front-end electronics connected has been irradiated with a 0.9 GeV electron beam up to a peak fluence of 3.5 x 10^14 e^-/cm^2, well beyond the level causing substrate type inversion. We irradiated one of the two sensors composing the module with a non-uniform profile with sigma=1.4 mm that simulates the conditions encountered in the BaBar experiment by the modules intersecting the horizontal machine plane. The position dependence of the charge collection properties and the depletion voltage have been investigated in detail using a 1060 nm LED and an innovative measuring technique based only on the digital output of the chip.Comment: 7 pages, 13 figures. Presented at the 2004 IEEE Nuclear Science Symposium, October 18-21, Rome, Italy. Accepted for publication by IEEE Transactions on Nuclear Scienc

    The molecular chaperone Hsp90 is a component of the cap-binding complex and interacts with the translational repressor Cup during Drosophila oogenesis

    Get PDF
    In metazoa, the spatio-temporal translation of diverse mRNAs is essential to guarantee proper oocyte maturation and early embryogenesis. The eukaryotic translation initiation factor 4E (eIF4E), which binds the 5′ cap structure of eukaryotic mRNAs, associates with either stimulatory or inhibitory factors to modulate protein synthesis. In order to identify novel factors that might act at the translational level during Drosophila oogenesis, we have undertaken a functional proteomic approach and isolated the product of the Hsp83 gene, the evolutionarily conserved chaperone Hsp90, as a specific component of the cap-binding complex. Here we report that Hsp90 interacts in vitro with the translational repressor Cup. In addition, we show that Hsp83 and cup interact genetically, since lowering Hsp90 activity enhances the oogenesis alterations linked to diverse cup mutant alleles. Hsp90 and Cup co-localize in the cytoplasm of the developing germ-line cells within the germarium, thus suggesting a common function from the earliest stages of oogenesis. Taken together, our data start elucidating the role of Hsp90 during Drosophila female germ-line development and strengthen the idea that Cup has multiple essential functions during egg chamber development

    Laue Lens Development for Hard X-rays (>60 keV)

    Full text link
    Results of reflectivity measurements of mosaic crystal samples of Cu (111) are reported. These tests were performed in the context of a feasibility study of a hard X-ray focusing telescope for space astronomy with energy passband from 60 to 600 keV. The technique envisaged is that of using mosaic crystals in transmission configuration that diffract X-rays for Bragg diffraction (Laue lens). The Laue lens assumed has a spherical shape with focal length ff. It is made of flat mosaic crystal tiles suitably positioned in the lens. The samples were grown and worked for this project at the Institute Laue-Langevin (ILL) in Grenoble (France), while the reflectivity tests were performed at the X-ray facility of the Physics Department of the University of Ferrara.Comment: 6 pages, 12 figures, accepted for publication in IEEE Transactions on Nuclear Scienc

    Distal Forearm Replantation Rehabilitation - Case Review

    Get PDF
    Actualmente, o desafio da reimplantação do membro superior pós-amputação tornou-se uma realidade alcançável e minuciosamente aperfeiçoada nas últimas décadas, e em permanente evolução. A opção cirúrgica de reimplantação deve ter em conta não apenas a análise exclusiva da viabilidade do reimplante, mas, fundamentalmente o seu potencial de recuperação funcional a longo prazo. Apresenta-se o caso clínico de um jovem de 18 anos, fumador, transferido do Hospital do Barreiro, vítima de acidente de trabalho, com traumatismo por corte, do qual resultou amputação distal do antebraço direito. O tempo de isquemia quente foi de 4horas, tendo sido submetido a cirurgia de reimplantação conjunta por Ortopedia e Cirurgia Plástica e Reconstrutiva (CPR) para reimplantação. Na sequência da cirurgia, foi precocemente referenciado a Medicina Física e de Reabilitação (MFR), realizando um programa de reabilitação funcional sequencial. Este trabalho visa enfatizar a importância do papel da MFR num precoce, criterioso e extenso programa de reabilitação, factor fundamental na recuperação funcional e prognóstico a longo prazo destas lesões e prevenção de complicações

    Polarisation measurements with a CdTe pixel array detector for Laue hard X-ray focusing telescopes

    Get PDF
    Polarimetry is an area of high energy astrophysics which is still relatively unexplored, even though it is recognized that this type of measurement could drastically increase our knowledge of the physics and geometry of high energy sources. For this reason, in the context of the design of a Gamma-Ray Imager based on new hard-X and soft gamma ray focusing optics for the next ESA Cosmic Vision call for proposals (Cosmic Vision 2015-2025), it is important that this capability should be implemented in the principal on-board instrumentation. For the particular case of wide band-pass Laue optics we propose a focal plane based on a thick pixelated CdTe detector operating with high efficiency between 60-600 keV. The high segmentation of this type of detector (1-2 mm pixel size) and the good energy resolution (a few keV FWHM at 500 keV) will allow high sensitivity polarisation measurements (a few % for a 10 mCrab source in 106s) to be performed. We have evaluated the modulation Q factors and minimum detectable polarisation through the use of Monte Carlo simulations (based on the GEANT 4 toolkit) for on and off-axis sources with power law emission spectra using the point spread function of a Laue lens in a feasible configuration.Comment: 10 pages, 6 pages. Accepted for publication in Experimental Astronom

    A focal plane detector design for a wide-band Laue-lens telescope

    Get PDF
    The energy range above 60 keV is important for the study of many open problems in high energy astrophysics such as the role of Inverse Compton with respect to synchrotron or thermal processes in GRBs, non thermal mechanisms in SNR, the study of the high energy cut-offs in AGN spectra, and the detection of nuclear and annihilation lines. Recently the development of high energy Laue lenses with broad energy bandpasses from 60 to 600 keV have been proposed for a Hard X ray focusing Telescope (HAXTEL) in order to study the X-ray continuum of celestial sources. The required focal plane detector should have high detection efficiency over the entire operative range, a spatial resolution of about 1 mm, an energy resolution of a few keV at 500 keV and a sensitivity to linear polarization. We describe a possible configuration of the focal plane detector based on several CdTe/CZT pixelated layers stacked together to achieve the required detection efficiency at high energy. Each layer can operate both as a separate position sensitive detector and polarimeter or work with other layers to increase the overall photopeak efficiency. Each layer has a hexagonal shape in order to minimize the detector surface required to cover the lens field of view. The pixels would have the same geometry so as to provide the best coupling with the lens point spread function and to increase the symmetry for polarimetric studies.Comment: 10 pages, 9 figure

    PP179—Identification of Drug–Drug Interactions Through a Digital Health Service

    Get PDF
    e74 Volume 35 Number 8S accounting for 21.2% and 16.2% of total AED consumption (DDD 163.7 and 125.2, respectively). In the same year, oxcarbazepine and lamotrigine were the most used new AEDs (10.91% and 10.79% of total; DDD 84.1 and 83.2, respectively), while gabapentin and pregabalin exhibited the higher incidence of use. The main indication of use was epileptic disorders for older AEDs and neuropathic pain for newer AEDs. A high number of patients treated with older AEDs, in particular carbamazepine, phenobarbital, and valproic acid, received coprescription at clinically relevant interaction risk. Among newer AEDs, lamotrigine showed a high annual rate of possible interaction. Conclusion: Significant differences were shown in the prescribing pattern of newer and older medications: older AEDs were mainly used in the treatment of epileptic disorders, while newer compounds were also preferred for conditions other than epilepsy, in particular neuropathic pain. The fall in the use of newer AEDs during 2007 agreed with revised reimbursement criteria for gabapentin and pregabalin. The coprescription should be evaluated with caution and avoided if possible. Drugs at risk of interactions should be replaced with others having same indication of use. Disclosure of Interest: None declared
    corecore