58 research outputs found

    A new era for Advances in Laboratory Medicine

    Get PDF
    Journal Citation Reports; PubMed; Impact factorInformes de citas de revistas; PubMed; Factor de impactoInformes de cites de revistes; PubMed; Factor d'impact

    The European Biological Variation Study (EuBIVAS):Biological variation data for testosterone, follicle stimulating hormone, prolactin, luteinizing hormone and dehydroepiandrosterone sulfate in men

    Get PDF
    BACKGROUND: Knowledge of biological variation (BV) of hormones is essential for interpretation of laboratory tests and for diagnostics of endocrinological and reproductive diseases. There is a lack of robust BV data for many hormones in men.METHODS: We used serum samples collected weekly over 10 weeks from the European Biological Variation Study (EuBIVAS) to determine BV of testosterone, follicle-stimulating hormone (FSH), prolactin, luteinizing hormone (LH) and dehydroepiandrosterone sulfate (DHEA-S) in 38 men. We derived within-subject (CVI) and between-subject (CVG) BV estimates by CV-ANOVA after trend, outlier, and homogeneity analysis and calculated reference change values, index of individuality (II), and analytical performance specifications.RESULTS: The CVI estimates were 10 % for testosterone, 8 % for FSH, 13 % for prolactin, 22 % for LH, and 9 % for DHEA-S, respectively. The IIs ranged between 0.14 for FSH to 0.66 for LH, indicating high individuality.CONCLUSIONS: In this study, we have used samples from the highly powered EuBIVAS study to derive BV estimates for testosterone, FSH, prolactin, LH and DHEA-S in men. Our data confirm previously published BV estimates of testosterone, FSH and LH. For prolactin and DHEA-S BV data for men are reported for the first time.</p

    The European Biological Variation Study (EuBIVAS):Biological variation data for testosterone, follicle stimulating hormone, prolactin, luteinizing hormone and dehydroepiandrosterone sulfate in men

    Get PDF
    BACKGROUND: Knowledge of biological variation (BV) of hormones is essential for interpretation of laboratory tests and for diagnostics of endocrinological and reproductive diseases. There is a lack of robust BV data for many hormones in men.METHODS: We used serum samples collected weekly over 10 weeks from the European Biological Variation Study (EuBIVAS) to determine BV of testosterone, follicle-stimulating hormone (FSH), prolactin, luteinizing hormone (LH) and dehydroepiandrosterone sulfate (DHEA-S) in 38 men. We derived within-subject (CVI) and between-subject (CVG) BV estimates by CV-ANOVA after trend, outlier, and homogeneity analysis and calculated reference change values, index of individuality (II), and analytical performance specifications.RESULTS: The CVI estimates were 10 % for testosterone, 8 % for FSH, 13 % for prolactin, 22 % for LH, and 9 % for DHEA-S, respectively. The IIs ranged between 0.14 for FSH to 0.66 for LH, indicating high individuality.CONCLUSIONS: In this study, we have used samples from the highly powered EuBIVAS study to derive BV estimates for testosterone, FSH, prolactin, LH and DHEA-S in men. Our data confirm previously published BV estimates of testosterone, FSH and LH. For prolactin and DHEA-S BV data for men are reported for the first time.</p

    Within- and between-subject biological variation data for tumor markers based on the European Biological Variation Study

    Get PDF
    Postponed access: the file will be available after 2022-05-10Objectives: Reliable biological variation (BV) data are required for the clinical use of tumor markers in the diagnosis and monitoring of treatment effects in cancer. The European Biological Variation Study (EuBIVAS) was established by the EFLM Biological Variation Working Group to deliver BV data for clinically important measurands. In this study, EuBIVAS-based BV estimates are provided for cancer antigen (CA) 125, CA 15-3, CA 19-9, carcinoembryonic antigen, cytokeratin-19 fragment, alpha‐fetoprotein and human epididymis protein 4. Methods: Subjects from five European countries were enrolled in the study, and weekly samples were collected from 91 healthy individuals (53 females and 38 males; 21–69 years old) for 10 consecutive weeks. All samples were analyzed in duplicate within a single run. After excluding outliers and homogeneity analysis, the BVs of tumor markers were determined by CV-ANOVA on trend-corrected data, when relevant (Rþraas method). Results: Marked individuality was found for all tumor markers. CYFRA 21-1 was the measurand with the highest index of individuality (II) at 0.67, whereas CA 19-9 had the lowest II at 0.07. The CV I s of HE4, CYFRA 21-1, CA 19-9, CA 125 and CA 15-3 of pre- and postmenopausal females were significantly different from each other. Conclusions: This study provides updated BV estimates for several tumor markers, and the findings indicate that marked individuality is characteristic. The use of reference change values should be considered when monitoring treatment of patients by means of tumor markers.publishedVersio

    European Biological Variation Study (EuBIVAS): Within- and between-subject biological variation estimates for serum thyroid biomarkers based on weekly samplings from 91 healthy participants

    Get PDF
    Objectives: Thyroid biomarkers are fundamental for the diagnosis of thyroid disorders and for the monitoring and treatment of patients with these diseases. The knowledge of biological variation (BV) is important to define analytical performance specifications (APS) and reference change values (RCV). The aim of this study was to deliver BV estimates for thyroid stimulating hormone (TSH), free thyroxine (FT4), free triiodothyronine (FT3), thyroglobulin (TG), and calcitonin (CT). Methods: Analyses were performed on serum samples obtained from the European Biological Variation Study population (91 healthy individuals from six European laboratories; 21–69 years) on the Roche Cobas e801 at the San Raffaele Hospital (Milan, Italy). All samples from each individual were evaluated in duplicate within a single run. The BV estimates with 95% CIs were obtained by CV-ANOVA, after analysis of variance homogeneity and outliers. Results: The within-subject (CV I ) BV estimates were for TSH 17.7%, FT3 5.0%, FT4 4.8%, TG 10.3, and CT 13.0%, all significantly lower than those reported in the literature. No significant differences were observed for BV estimates between men and women. Conclusions: The availability of updated, in the case of CT not previously published, BV estimates for thyroid markers based on the large scale EuBIVAS study allows for refined APS and associated RCV applicable in the diagnosis and management of thyroid and related diseases.publishedVersio

    The importance of having a flexible scope ISO 15189 accreditation and quality specifications based on biological variation – the case of validation of the biochemistry analyzer Dimension Vista

    Get PDF
    Introduction: Technological innovation requires the laboratories to ensure that modifications or incorporations of new techniques do not alter the quality of their results. In an ISO 15189 accredited laboratory, flexible scope accreditation facilitates the inclusion of these changes prior to accreditation body evaluation. A strategy to perform the validation of a biochemistry analyzer in an accredited laboratory having a flexible scope is shown. Materials and methods: A validation procedure including the evaluation of imprecision and bias of two Dimension Vista analysers 1500 was conducted. Comparability of patient results between one of them and the lately replaced Dimension RxL Max was evaluated. All studies followed the respective Clinical and Laboratory Standards Institute (CLSI) protocols. 30 chemistry assays were studied. Coefficients of variation, percent bias and total error were calculated for all tests and biological variation was considered as acceptance criteria. Quality control material and patient samples were used as test materials. Interchangeability of the results was established by processing forty patients’ samples in both devices. Results: 27 of the 30 studied parameters met allowable performance criteria. Sodium, chloride and magnesium did not fulfil acceptance criteria. Evidence of interchangeability of patient results was obtained for all parameters except magnesium, NT-proBNP, cTroponin I and C-reactive protein. Conclusions: A laboratory having a well structured and documented validation procedure can opt to get a flexible scope of accreditation. In addition, performing these activities prior to use on patient samples may evidence technical issues which must be corrected to minimize their impact on patient results

    Experience on how to implement a preanalytical and POCT unit in Madrid’s IFEMA field hospital during this unprecedented COVID-19 emergency

    Get PDF
    To fight the virus SARS-CoV-2 spread to Europe from China and to give support to the collapsed public health system, the Spanish Health Authorities developed a field hospital located in the facilities of Madrid exhibition centre (IFEMA) to admit and treat patients diagnosed with SARS-CoV-2 infectious disease (COVID-19). The Department of Laboratory Medicine of La Paz University Hospital in Madrid (LMD-HULP) was designated to provide laboratory services. Due to the emergency, the IFEMA field hospital had to be prepared for patient admission in less than 1 week and the laboratory professionals had to collaborate in a multidisciplinary group to assure that resources were available to start on time. The LMD-HULP participated together with the managers in the design of the tests portfolio and the integration of the healthcare information systems (IS) (hospital IS, laboratory IS and POCT management system). Laboratorians developed a strategy to quickly train clinicians and nurses on test requests, sample collection procedures and management/handling of the POCT blood gas analyser both by written materials and training videos. The IFEMA®s preanalytical unit managed 3782 requests, and more than 11,000 samples from March 27th to April 30th. Furthermore, 1151 samples were measured by blood gas analysers. In conclusion, laboratory professionals must be resilient and have to respond timely in emergencies as this pandemic. The lab’s personnel selection, design and monitoring indicators to maintain and further improve the quality and value of laboratory services is crucial to support medical decision making and provide better patient care

    The European Biological Variation Study (EuBIVAS): Biological Variation Data for Coagulation Markers Estimated by a Bayesian Model

    Get PDF
    Background For biological variation (BV) data to be safely used, data must be reliable and relevant to the population in which they are applied. We used samples from the European Biological Variation Study (EuBIVAS) to determine BV of coagulation markers by a Bayesian model robust to extreme observations and used the derived within-participant BV estimates [CVP(i)] to assess the applicability of the BV estimates in clinical practice. Method Plasma samples were drawn from 92 healthy individuals for 10 consecutive weeks at 6 European laboratories and analyzed in duplicate for activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen, D-dimer, antithrombin (AT), protein C, protein S free, and factor VIII (FVIII). A Bayesian model with Student t likelihoods for samples and replicates was applied to derive CVP(i) and predicted BV estimates with 95% credibility intervals. Results For all markers except D-dimer, CVP(i) were homogeneously distributed in the overall study population or in subgroups. Mean within-subject estimates (CVI) were <5% for APTT, PT, AT, and protein S free, <10% for protein C and FVIII, and <12% for fibrinogen. For APTT, protein C, and protein S free, estimates were significantly lower in men than in women ≀50 years. Conclusion For most coagulation markers, a common CVI estimate for men and women is applicable, whereas for APTT, protein C, and protein S free, sex-specific reference change values should be applied. The use of a Bayesian model to deliver individual CVP(i) allows for improved interpretation and application of the data.publishedVersio

    Within- and between-subject biological variation data for serum zinc, copper and selenium obtained from 68 apparently healthy Turkish subjects

    Get PDF
    Postponed access: the file will be available after 2022-10-22Objectives: Trace elements (TrEL) are nutritionally essential components in maintaining health and preventing diseases. There is a lack of reliable biological variation (BV) data for TrELs, required for the diagnosis and monitoring of TrEL disturbances. In this study, we aimed to provide updated within- and between-subject BV estimates for zinc (Zn), copper (Cu) and selenium (Se). Methods: Weekly serum samples were drawn from 68 healthy subjects (36 females and 32 males) for 10 weeks and stored at −80 °C prior to analysis. Serum Zn, Cu and Se levels were measured using inductively-coupled plasma mass spectrometry (ICP-MS). Outlier and variance homogeneity analyses were performed followed by CV-ANOVA (RĂžraas method) to determine BV and analytical variation estimates with 95% CI and the associated reference change values (RCV) for all subjects, males and females. Results: Significant differences in mean concentrations between males and females were observed, with absolute and relative (%) differences for Zn at 0.5 ÎŒmol/L (3.5%), Cu 2.0 ÎŒmol/L (14.1%) and Se 0.06 ÎŒmol/L (6.0%). The within-subject BV (CVI [95% CI]) estimates were 8.8% (8.2–9.3), 7.8% (7.3–8.3) and 7.7% (7.2–8.2) for Zn, Cu and Se, respectively. Within-subject biological variation (CVI) estimates derived for male and female subgroups were similar for all three TrELs. Marked individuality was observed for Cu and Se. Conclusions: The data of this study provides updated BV estimates for serum Zn, Cu and Se derived from a stringent protocol and state of the art methodologies. Furthermore, Cu and Se display marked individuality, highlighting that population based reference limits should not be used in the monitoring of patients.publishedVersio

    The European Biological Variation Study (EuBIVAS): Biological Variation Data for Coagulation Markers Estimated by a Bayesian Model.

    Get PDF
    Abstract Background For biological variation (BV) data to be safely used, data must be reliable and relevant to the population in which they are applied. We used samples from the European Biological Variation Study (EuBIVAS) to determine BV of coagulation markers by a Bayesian model robust to extreme observations and used the derived within-participant BV estimates [CVP(i)] to assess the applicability of the BV estimates in clinical practice. Method Plasma samples were drawn from 92 healthy individuals for 10 consecutive weeks at 6 European laboratories and analyzed in duplicate for activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen, D-dimer, antithrombin (AT), protein C, protein S free, and factor VIII (FVIII). A Bayesian model with Student t likelihoods for samples and replicates was applied to derive CVP(i) and predicted BV estimates with 95% credibility intervals. Results For all markers except D-dimer, CVP(i) were homogeneously distributed in the overall study population or in subgroups. Mean within-subject estimates (CVI) were &lt;5% for APTT, PT, AT, and protein S free, &lt;10% for protein C and FVIII, and &lt;12% for fibrinogen. For APTT, protein C, and protein S free, estimates were significantly lower in men than in women ≀50 years. Conclusion For most coagulation markers, a common CVI estimate for men and women is applicable, whereas for APTT, protein C, and protein S free, sex-specific reference change values should be applied. The use of a Bayesian model to deliver individual CVP(i) allows for improved interpretation and application of the data
    • 

    corecore