416 research outputs found

    Proprioceptive changes impair balance control in individuals with chronic obstructive pulmonary disease

    Get PDF
    Copyright @ 2013 Janssens et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.Introduction: Balance deficits are identified as important risk factors for falling in individuals with chronic obstructive pulmonary disease (COPD). However, the specific use of proprioception, which is of primary importance during balance control, has not been studied in individuals with COPD. The objective was to determine the specific proprioceptive control strategy during postural balance in individuals with COPD and healthy controls, and to assess whether this was related to inspiratory muscle weakness. Methods: Center of pressure displacement was determined in 20 individuals with COPD and 20 age/gender-matched controls during upright stance on an unstable support surface without vision. Ankle and back muscle vibration were applied to evaluate the relative contribution of different proprioceptive signals used in postural control. Results: Individuals with COPD showed an increased anterior-posterior body sway during upright stance (p=0.037). Compared to controls, individuals with COPD showed an increased posterior body sway during ankle muscle vibration (p=0.047), decreased anterior body sway during back muscle vibration (p=0.025), and increased posterior body sway during simultaneous ankle-muscle vibration (p=0.002). Individuals with COPD with the weakest inspiratory muscles showed the greatest reliance on ankle muscle input when compared to the stronger individuals with COPD (p=0.037). Conclusions: Individuals with COPD, especially those with inspiratory muscle weakness, increased their reliance on ankle muscle proprioceptive signals and decreased their reliance on back muscle proprioceptive signals during balance control, resulting in a decreased postural stability compared to healthy controls. These proprioceptive changes may be due to an impaired postural contribution of the inspiratory muscles to trunk stability. Further research is required to determine whether interventions such as proprioceptive training and inspiratory muscle training improve postural balance and reduce the fall risk in individuals with COPD.This work was supported by the Research Foundation – Flanders (FWO) grants 1.5.104.03, G.0674.09, G.0598.09N and G.0871.13N

    Impaired Postural Control Reduces Sit-to-Stand-to-Sit Performance in Individuals with Chronic Obstructive Pulmonary Disease

    Get PDF
    Abstract Background: Functional activities, such as the sit-to-stand-to-sit (STSTS) task, are often impaired in individuals with chronic obstructive pulmonary disease (COPD). The STSTS task places a high demand on the postural control system, which has been shown to be impaired in individuals with COPD. It remains unknown whether postural control deficits contribute to the decreased STSTS performance in individuals with COPD. Methods: Center of pressure displacement was determined in 18 individuals with COPD and 18 age/gender-matched controls during five consecutive STSTS movements with vision occluded. The total duration, as well as the duration of each sit, sit-to-stand, stand and stand-to-sit phase was recorded. Results: Individuals with COPD needed significantly more time to perform five consecutive STSTS movements compared to healthy controls (1966 vs. 1364 seconds, respectively; p = 0.001). The COPD group exhibited a significantly longer stand phase (p = 0.028) and stand-to-sit phase (p = 0.001) compared to the control group. In contrast, the duration of the sit phase (p = 0.766) and sit-to-stand phase (p = 0.999) was not different between groups. Conclusions: Compared to healthy individuals, individuals with COPD needed significantly more time to complete those phases of the STSTS task that require the greatest postural control. These findings support the proposition that suboptimal postural control is an important contributor to the decreased STSTS performance in individuals with COPD

    Bronchiectasis in children after renal or liver transplantation: A report of five cases

    Get PDF
    More effective immunosuppressive treatment in children following organ transplantation has significantly improved the survival of the grafts. Therefore, quality of life, long-term prognosis and adverse drug reactions have become more important. One of the main complications of immunosuppressive drugs is infections of the respiratory tract, but irreversible damage to the airways has not been described after renal or liver transplantation. Five children following transplantation of kidney or liver were referred to the Paediatric Pulmonology department because of chronic respiratory complaints. Pulmonary function tests and HRCT scan were performed as routine patient care. Four children with a renal transplant and one with a liver transplant showed chronic bronchitis and moderate to severe airways obstruction. HRCT showed bronchiectasis in all of them. We speculate that the immunosuppressive treatment (in) directly contributes to irreversible airway damage. We recommend including follow-up of lung function in the post-transplantation protocol and considering bronchiectasis in case of respiratory symptoms, to try preventing further damage to the lung

    Key paediatric messages from Amsterdam

    Get PDF
    The Paediatric Assembly of the European Respiratory Society (ERS) maintained its high profile at the 2015 ERS International Congress in Amsterdam. There were symposia on preschool wheeze, respiratory sounds and cystic fibrosis; an educational skills workshop on paediatric respiratory resuscitation; a hot topic session on risk factors and early origins of respiratory diseases; a meet the expert session on paediatric lung function test reference values; and the annual paediatric grand round. In this report the Chairs of the Paediatric Assembly’s Groups highlight the key mess

    LISA pathfinder optical interferometry

    No full text
    The LISA Technology Package (LTP) aboard of LISA pathfinder mission is dedicated to demonstrate and verify key technologies for LISA, in particular drag free control, ultra-precise laser interferometry and gravitational sensor. Two inertial sensor, the optical interferometry in between combined with the dimensional stable Glass ceramic Zerodur structure are setting up the LTP. The validation of drag free operation of the spacecraft is planned by measuring laser interferometrically the relative displacement and tilt between two test masses (and the optical bench) with a noise levels of 10pm/[square root of]Hz and 10 nrad/[square root of]Hz between 3mHz and 30mHz. This performance and additionally overall environmental tests was currently verified on EM level. The OB structure is able to support two inertial sensors ([approximate]17kg each) and to withstand 25 g design loads as well as 0...40°C temperature range. Optical functionality was verified successfully after environmental tests. The engineering model development and manufacturing of the optical bench and interferometry hardware and their verification tests will be presented

    Associations between Measures of Structural Morphometry and Sensorimotor Performance in Individuals with Nonspecific Low Back Pain

    Get PDF
    ABSTRACT BACKGROUND AND PURPOSE: To date, most structural brain imaging studies in individuals with nonspecific low back pain have evaluated volumetric changes. These alterations are particularly found in sensorimotor-related areas. Although it is suggested that specific measures, such as cortical surface area and cortical thickness, reflect different underlying neural architectures, the literature regarding these different measures in individuals with nonspecific low back pain is limited. Therefore, the current study was designed to investigate the association between the performance on a sensorimotor task, more specifically the sit-to-stand-to-sit task, and cortical surface area and cortical thickness in individuals with nonspecific low back pain and healthy controls

    Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children

    Get PDF
    BACKGROUND: Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). METHODS: A total of 71 subjects (6–60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). RESULTS: Success rate was high (≥ 84%) in both devices for both adults and children. The subjects represented a FE(NO )range of 8–147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. CONCLUSION: The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children. The new hand-held device will enable the introduction of exhaled NO measurements into the primary health care

    Protein disulfide isomerases as CSF biomarkers for the neuronal response to tau pathology

    Get PDF
    Introduction: Cerebrospinal fluid (CSF) biomarkers for specific cellular disease processes are lacking for tauopathies. In this translational study we aimed to identify CSF biomarkers reflecting early tau pathology-associated unfolded protein response (UPR) activation. Methods: We employed mass spectrometry proteomics and targeted immunoanalysis in a combination of biomarker discovery in primary mouse neurons in vitro and validation in patient CSF from two independent large multicentre cohorts (EMIF-AD MBD, n = 310; PRIDE, n = 771). Results: First, we identify members of the protein disulfide isomerase (PDI) family in the neuronal UPR-activated secretome and validate secretion upon tau aggregation in vitro. Next, we demonstrate that PDIA1 and PDIA3 levels correlate with total- and phosphorylated-tau levels in CSF. PDIA1 levels are increased in CSF from AD patients compared to controls and patients with tau-unrelated frontotemporal and Lewy body dementia (LBD). Highlights: Neuronal unfolded protein response (UPR) activation induces the secretion of protein disulfide isomerases (PDIs) in vitro. PDIA1 is secreted upon tau aggregation in neurons in vitro. PDIA1 and PDIA3 levels correlate with total and phosphorylated tau levels in CSF. PDIA1 levels are increased in CSF from Alzheimer's disease (AD) patients compared to controls. PDIA1 levels are not increased in CSF from tau-unrelated frontotemporal dementia (FTD) and Lewy body dementia (LBD) patients

    Perceptions of institutional complexity and lobbyists’ decisions to join lobbying coalitions – evidence from the European Union context

    Get PDF
    YesWe use data from in-depth interviews with business lobbyists in Brussels to investigate why they choose to join lobbying coalitions. We find that lobbyists face two competing institutional incentives. First, they are confronted with incentives to ally with other European organisations, develop multilateral policy messages, and communicate messages to the Commission and the Parliament. Simultaneously, they face inducements to join narrower coalitions, develop bilateral policy messages, and direct those messages at the Council. Lobbyists’ receptivity to these incentives – and thus their choices of lobbying coalitions – differs with their age, educational background, and with the type and ownership structure of the organisations they represent. Combined, our findings contribute to the limited, mainly American literature on interest coalitions by demonstrating that lobbyists operate in complex institutional environments, and that their interpretations of and reactions to institutional complexity are shaped by individual- and organisational-level factors
    • …
    corecore