91 research outputs found
Does your electronic butler owe you a duty of confidentiality?
As artificial intelligence (AI) advances the legal issues have not progressed in step and principles that exist have become outdated in a relatively short time. Privacy is a major concern and the myriad of devices that store data for wide ranging purposes risk breaches of privacy. Treating such a breach as a design defect or technical fault, does not reflect the complexities of legal liability that apply to robotics. Where advanced levels of AI are involved, such as with electronic butlers and carers used increasingly to assist vulnerable and ageing populations, the question of whether a robot owes a duty of confidentiality to the person for whom they are caring is becoming ever more pertinent. This question is considered in detail and it is concluded that a duty may be owed in some cases. After a brief introduction (I.) the article picks up on the aspects of legal agency and AI (II.) and examines robots as social beeings (III.), their relation- ship to duty (IV.) as well as their capacity as "extended cognition" (V.). These aspects are then brought in con- text with issues of data protection (VI.) and the general relationship between civil law, ethics and robotics (VII.) before conclusions (VIII.) are drawn
Patient data ownership
Response of article in JAMA advocating patient data ownershi
Treatment of human lens epithelium with high levels of nanoceria leads to reactive oxygen species mediated apoptosis
Nanoceria (cerium oxide nanoparticles) have been shown to protect human lens epithelial cells (HLECs) from oxidative stress when used at low concentrations. However, there is a lack of understanding about the mechanism of the cytotoxic and genotoxic effects of nanoceria when used at higher concentrations. Here, we investigated the impact of 24-hour exposure to nanoceria in HLECs. Nanoceria’s effects on basal reactive oxygen species (ROS), mitochondrial morphology, membrane potential, ATP, genotoxicity, caspase activation and apoptotic hallmarks were investigated. Scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM-EDX) studies on isolated mitochondria revealed significant uptake and localization of nanoceria in the mitochondria. At high nanoceria concentrations (400 µg mL−1), intracellular levels of ROS were increased and the HLECs exhibited classical hallmarks of apoptosis. These findings concur with the cells maintaining normal ATP levels necessary to execute the apoptotic process. These results highlight the need for nanoceria dose-effect studies on a range of cells and tissues to identify therapeutic concentrations in vitro or in viv
Cyclodextrin enhances corneal tolerability and reduces ocular toxicity caused by diclofenac
With advances in refractive surgery and demand for cataract removal and lens replacement, the ocular use of nonsteroidal anti-inflammatory drugs (NSAIDs) has increased. One of the most commonly used NSAIDs is diclofenac (Diclo). In this study, cyclodextrins (CDs), α-, β-, γ-, and HP-β-CDs, were investigated with in vitro irritation and in vivo ulceration models in rabbits to reduce Diclo toxicity. Diclo-, α-, β-, γ-, and HP-β-CD inclusion complexes were prepared and characterized and Diclo-CD complexes were evaluated for corneal permeation, red blood cell (RBCs) haemolysis, corneal opacity/permeability, and toxicity. Guest- (Diclo-) host (CD) solid inclusion complexes were formed only with β-, γ-, and HP-β-CDs. Amphipathic properties for Diclo were recorded and this surfactant-like functionality might contribute to the unwanted effects of Diclo on the surface of the eye. Contact angle and spreading coefficients were used to assess Diclo-CDs in solution. Reduction of ocular toxicity 3-fold to16-fold and comparable corneal permeability to free Diclo were recorded only with Diclo-γ-CD and Diclo-HP-β-CD complexes. These two complexes showed faster healing rates without scar formation compared with exposure to the Diclo solution and to untreated groups. This study also highlighted that Diclo-γ-CD and Diclo-HP-β-CD demonstrated fast healing without scar formation
Coil conversion to β-strand induced by dimerisation
Most molecular processes in living organisms rely on protein–protein interactions, many of which are mediated by β-sheet interfaces; this study investigates the formation of β-sheet interfaces through the conversion of coils into β-strands. Following an exhaustive search in the Protein Data Bank, the corresponding structural dimorphic fragments were extracted, characterised and analysed. Their short strand lengths and specific amino acid profiles indicate that dimorphic β-strand interfaces are likely to be less stable than standard ones and could even convert to coil interfaces if their environment changes. Moreover, the construction of a simple classifier able to discriminate between the sequences of dimorphic and standard β-strand interfaces suggests that the nature of those dimorphic sequences could be predicted, providing a novel means of identifying proteins capable of forming dimers
Age-related changes in eye lens biomechanics, morphology, refractive index and transparency
Life-long eye lens function requires an appropriate gradient refractive index, biomechanical integrity and transparency. We conducted an extensive study of wild-type mouse lenses 1-30 months of age to define common age-related changes. Biomechanical testing and morphometrics revealed an increase in lens volume and stiffness with age. Lens capsule thickness and peripheral fiber cell widths increased between 2 to 4 months of age but not further, and thus, cannot account for significant age-dependent increases in lens stiffness after 4 months. In lenses from mice older than 12 months, we routinely observed cataracts due to changes in cell structure, with anterior cataracts due to incomplete suture closure and a cortical ring cataract corresponding to a zone of compaction in cortical lens fiber cells. Refractive index measurements showed a rapid growth in peak refractive index between 1 to 6 months of age, and the area of highest refractive index is correlated with increases in lens nucleus size with age. These data provide a comprehensive overview of age-related changes in murine lenses, including lens size, stiffness, nuclear fraction, refractive index, transparency, capsule thickness and cell structure. Our results suggest similarities between murine and primate lenses and provide a baseline for future lens aging studies
Imaging shear stress distribution and evaluating the stress concentration factor of the human eye.
Healthy eyes are vital for a better quality of human life. Historically, for man-made materials, scientists and engineers use stress concentration factors to characterise the effects of structural non-homogeneities on their mechanical strength. However, such information is scarce for the human eye. Here we present the shear stress distribution profiles of a healthy human cornea surface in vivo using photo-stress analysis tomography, which is a non-intrusive and non-X-ray based method. The corneal birefringent retardation measured here is comparable to that of previous studies. Using this, we derive eye stress concentration factors and the directional alignment of major principal stress on the surface of the cornea. Similar to thermometers being used for monitoring the general health in humans, this report provides a foundation to characterise the shear stress carrying capacity of the cornea, and a potential bench mark for validating theoretical modelling of stresses in the human eye in future
Age-related changes in eye lens biomechanics, morphology, refractive index and transparency
Life-long eye lens function requires an appropriate gradient refractive index, biomechanical integrity and transparency. We conducted an extensive study of wild-type mouse lenses 1-30 months of age to define common age-related changes. Biomechanical testing and morphometrics revealed an increase in lens volume and stiffness with age. Lens capsule thickness and peripheral fiber cell widths increased between 2 to 4 months of age but not further, and thus, cannot account for significant age-dependent increases in lens stiffness after 4 months. In lenses from mice older than 12 months, we routinely observed cataracts due to changes in cell structure, with anterior cataracts due to incomplete suture closure and a cortical ring cataract corresponding to a zone of compaction in cortical lens fiber cells. Refractive index measurements showed a rapid growth in peak refractive index between 1 to 6 months of age, and the area of highest refractive index is correlated with increases in lens nucleus size with age. These data provide a comprehensive overview of age-related changes in murine lenses, including lens size, stiffness, nuclear fraction, refractive index, transparency, capsule thickness and cell structure. Our results suggest similarities between murine and primate lenses and provide a baseline for future lens aging studies
COPD care delivery pathways in five European Union countries : mapping and health care professionals' perceptions
Background: COPD is among the leading causes of chronic morbidity and mortality in the European Union with an estimated annual economic burden of €25.1 billion. Various care pathways for COPD exist across Europe leading to different responses to similar problems. Determining these differences and the similarities may improve health and the functioning of health services.
Objective: The aim of this study was to compare COPD patients’ care pathway in five European Union countries including England, Ireland, the Netherlands, Greece, and Germany and to explore health care professionals’ (HCPs) perceptions about the current pathways.
Methods: HCPs were interviewed in two stages using a qualitative, semistructured email interview and a face-to-face semistructured interview.
Results: Lack of communication among different health care providers managing COPD and comorbidities was a common feature of the studied care pathways. General practitioners/family doctors are responsible for liaising between different teams/services, except in Greece where this is done through pulmonologists. Ireland and the UK are the only countries with services for patients at home to shorten unnecessary hospital stay. HCPs emphasized lack of communication, limited resources, and poor patient engagement as issues in the current pathways. Furthermore, no specified role exists for pharmacists and informal carers.
Conclusion: Service and professional integration between care settings using a unified system targeting COPD and comorbidities is a priority. Better communication between health care providers, establishing a clear role for informal carers, and enhancing patients’ engagement could optimize current care pathways resulting in a better integrated system
The importance of parameter choice in modelling dynamics of the eye lens
The lens provides refractive power to the eye and is capable of altering ocular focus in response to visual demand. This capacity diminishes with age. Current biomedical technologies, which seek to design an implant lens capable of replicating the function of the biological lens, are unable as yet to provide such an implant with the requisite optical quality or ability to change the focussing power of the eye. This is because the mechanism of altering focus, termed accommodation, is not fully understood and seemingly conflicting theories require experimental support which is difficult to obtain from the living eye. This investigation presents finite element models of the eye lens based on data from human lenses aged 16 and 35 years that consider the influence of various modelling parameters, including material properties, a wide range of angles of force application and capsular thickness. Results from axisymmetric models show that the anterior and posterior zonules may have a greater impact on shape change than the equatorial zonule and that choice of capsular thickness values can influence the results from modelled simulations
- …