9 research outputs found

    The development and validation of a self-administered quality-ofl life outcome measure for young, active patients with symptomatic hip disease : the International Hip Outcome Tool (iHOT-33)

    No full text
    Purpose The purpose of this study was to develop a self-administered evaluative tool to measure health-related quality of life in young, active patients with hip disorders. Methods This outcome measure was developed for active patients (aged 18 to 60 years, Tegner activity level ≥4) presenting with a variety of symptomatic hip conditions. This multicenter study recruited patients from international hip arthroscopy and arthroplasty surgeon practices. The outcome was created using a process of item generation (51 patients), item reduction (150 patients), and pretesting (31 patients). The questionnaire was tested for test-retest reliability (123 patients); face, content, and construct validity (51 patients); and responsiveness over a 6-month period in post-arthroscopy patients (27 patients). Results Initially, 146 items were identified. This number was reduced to 60 through item reduction, and the items were categorized into 4 domains: (1) symptoms and functional limitations; (2) sports and recreational physical activities; (3) job-related concerns; and (4) social, emotional, and lifestyle concerns. The items were then formatted using a visual analog scale. Test-retest reliability showed Pearson correlations greater than 0.80 for 33 of the 60 questions. The intraclass correlation statistic was 0.78, and the Cronbach α was .99. Face validity and content validity were ensured during development, and construct validity was shown with a correlation of 0.81 to the Non-Arthritic Hip Score. Responsiveness was shown with a paired t test (P ≤ .01), effect size of 2.0, standardized response mean of 1.7, responsiveness ratio of 6.7, and minimal clinically important difference of 6 points. Conclusions We have developed a new quality-of-life patient-reported outcome measure, the 33-item International Hip Outcome Tool (iHOT-33). This questionnaire uses a visual analog scale response format designed for computer self-administration by young, active patients with hip pathology. Its development has followed the most rigorous methodology involving a very large number of patients. The iHOT-33 has been shown to be reliable; shows face, content, and construct validity; and is highly responsive to clinical change. In our opinion the iHOT-33 can be used as a primary outcome measure for prospective patient evaluation and randomized clinical trials

    Antibacterial Envelope to Prevent Cardiac Implantable Device Infection

    Full text link
    BACKGROUND Infections after placement of cardiac implantable electronic devices (CIEDs) are associated with substantial morbidity and mortality. There is limited evidence on prophylactic strategies, other than the use of preoperative antibiotics, to prevent such infections. METHODS We conducted a randomized, controlled clinical trial to assess the safety and efficacy of an absorbable, antibiotic-eluting envelope in reducing the incidence of infection associated with CIED implantations. Patients who were undergoing a CIED pocket revision, generator replacement, or system upgrade or an initial implantation of a cardiac resynchronization therapy defibrillator were randomly assigned, in a 1:1 ratio, to receive the envelope or not. Standard-of-care strategies to prevent infection were used in all patients. The primary end point was infection resulting in system extraction or revision, long-term antibiotic therapy with infection recurrence, or death, within 12 months after the CIED implantation procedure. The secondary end point for safety was procedure-related or system-related complications within 12 months. RESULTS A total of 6983 patients underwent randomization: 3495 to the envelope group and 3488 to the control group. The primary end point occurred in 25 patients in the envelope group and 42 patients in the control group (12-month Kaplan-Meier estimated event rate, 0.7% and 1.2%, respectively; hazard ratio, 0.60; 95% confidence interval [CI], 0.36 to 0.98; P = 0.04). The safety end point occurred in 201 patients in the envelope group and 236 patients in the control group (12-month Kaplan-Meier estimated event rate, 6.0% and 6.9%, respectively; hazard ratio, 0.87; 95% CI, 0.72 to 1.06; P<0.001 for noninferiority). The mean (±SD) duration of follow-up was 20.7±8.5 months. Major CIED-related infections through the entire follow-up period occurred in 32 patients in the envelope group and 51 patients in the control group (hazard ratio, 0.63; 95% CI, 0.40 to 0.98). CONCLUSIONS Adjunctive use of an antibacterial envelope resulted in a significantly lower incidence of major CIED infections than standard-of-care infection-prevention strategies alone, without a higher incidence of complications. (Funded by Medtronic; WRAP-IT ClinicalTrials.gov number, NCT02277990.)

    Antibacterial Envelope to Prevent Cardiac Implantable Device Infection

    No full text
    Background Infections after placement of cardiac implantable electronic devices (CIEDs) are associated with substantial morbidity and mortality. There is limited evidence on prophylactic strategies, other than the use of preoperative antibiotics, to prevent such infections. Methods We conducted a randomized, controlled clinical trial to assess the safety and efficacy of an absorbable, antibiotic-eluting envelope in reducing the incidence of infection associated with CIED implantations. Patients who were undergoing a CIED pocket revision, generator replacement, or system upgrade or an initial implantation of a cardiac resynchronization therapy defibrillator were randomly assigned, in a 1:1 ratio, to receive the envelope or not. Standard-of-care strategies to prevent infection were used in all patients. The primary end point was infection resulting in system extraction or revision, long-term antibiotic therapy with infection recurrence, or death, within 12 months after the CIED implantation procedure. The secondary end point for safety was procedure-related or system-related complications within 12 months. Results A total of 6983 patients underwent randomization: 3495 to the envelope group and 3488 to the control group. The primary end point occurred in 25 patients in the envelope group and 42 patients in the control group (12-month Kaplan-Meier estimated event rate, 0.7% and 1.2%, respectively; hazard ratio, 0.60; 95% confidence interval [CI], 0.36 to 0.98; P=0.04). The safety end point occurred in 201 patients in the envelope group and 236 patients in the control group (12-month Kaplan-Meier estimated event rate, 6.0% and 6.9%, respectively; hazard ratio, 0.87; 95% CI, 0.72 to 1.06; P&lt;0.001 for noninferiority). The mean (+/- SD) duration of follow-up was 20.7 +/- 8.5 months. Major CIED-related infections through the entire follow-up period occurred in 32 patients in the envelope group and 51 patients in the control group (hazard ratio, 0.63; 95% CI, 0.40 to 0.98). Conclusions Adjunctive use of an antibacterial envelope resulted in a significantly lower incidence of major CIED infections than standard-of-care infection-prevention strategies alone, without a higher incidence of complications
    corecore