261 research outputs found

    Observation of Tool Life of Micro End Mills

    Get PDF
    Prediction of mechanical machining tool life is an integral part of commercial manufacturing. Failure of micro end mills is still not well understood, and further work needs to be done to accurately predict tool life. The objective of this study is to observe the distribution of tool life for micro end mills under aggressive machining conditions without lubri-cation for 300-um-diameter micro end mills while machining 6061-T6 aluminum alloy. The average tool life was 3 to 7 times greater for the nanocrystalline diamond (NCD) coated micro end mills as compared with the uncoated (as received) tools. For both NCD coated and uncoated micro end mills the tool life increased as the cutting speed was in-creased from 32 to 48 m/min, suggesting the presence of a built-up-edge during machining. The variance in the tool life data was approximately an order of magnitude greater than what is expected in macro-scale machining

    One-year clinical results of restorations using a novel self-adhesive resin-based bulk-fill restorative.

    Get PDF
    This prospective study assessed the dual-curing self-adhesive bulk-fill restorative Surefil one. The restorations were placed and reviewed by dental practitioners who are members of a practice-based research network in the United States. Seven practitioners filled 60 cavities (20 class I, 19 class II and 21 class V) in 41 patients with Surefil one without adhesive, according to the manufacturer's instructions. The restorations were evaluated using modified USPHS criteria at baseline, 3 months, and 1 year. Patients were also contacted to report postoperative hypersensitivity one to four weeks after placement. The only patient that showed moderate hypersensitivity after 1 year had previously reported symptoms that were unlikely associated to the class I molar restoration. One class II restoration in a fractured maxillary molar was partially lost. The remaining restorations were found to be in clinically acceptable condition resulting in an annual failure rate of 2%. Color match showed the lowest number of acceptable scores (88%) revealing significant changes over time (P = 0.0002). No significant differences were found for the other criteria (P > 0.05). The novel self-adhesive bulk-fill restorative showed clinically acceptable results in stress-bearing class I and II as well as non-retentive class V cavities at 1-year recall

    Measurement of Tool-Workpiece Interface Temperature Distribution in Friction Stir Welding

    Get PDF
    The objective of this work is to develop an improved temperature measurement system for friction stir welding (FSW). FSW is a solid-state joining process enabling welds with excellent metallurgical and mechanical properties, as well as significant energy consumption and cost savings compared to traditional fusion welding processes. The measurement of temperatures during FSW is needed for process monitoring, heat transfer model verification and process control, but current methods have limitations due to their restricted spatial and temporal resolution. Previous work showed that temperatures at the tool shoulder-workpiece interface can be measured and utilized for closed-loop control of temperature. Adding an additional thermocouple at the tool pin-workpiece interface and performing a calibration of the measurement to gain better insight into the temperature distribution in the weld zone improved the method. Both thermocouples were placed in through holes right at the interface of tool so that the sheaths are in direct contact with the workpiece material. This measurement strategy reveals dynamic temperature variations at the shoulder and the pin within a single rotation of the tool in realtime. It was found that the highest temperatures are at the shoulder interface between the advancing side and the trailing edge of the tool, closer to the advancing side. The temperature distribution was mostly affected by travel speed and the temperature difference within one tool rotation was found to be between 10 C and 50 C, depending on the process parameters. The dynamic temperature measurements obtained with the current system are of unmatched resolution, fast, and reliable and are likely to be of interest for both fundamental studies and process control of FSW

    IMECE2008-69051 EXPERIMENTAL STUDY OF ADIABATIC WATER LIQUID-VAPOR TWO-PHASE PRESSURE DROP ACROSS AN ARRAY OF STAGGERED MICRO-PIN-FINS

    Get PDF
    ABSTRACT This study concerns pressure drop of adiabatic water liquid-vapor two-phase flow across an array of 1950 staggered square micro-pin-fins having a 200×200 micron cross-section by a 670 micron height. The ratios of longitudinal pitch and transverse pitch to pin-fin equivalent diameter are equal to 2. An inline immersion heater upstream of the micro-pin-fin test module was employed to produce liquid-vapor two-phase mixture, which flowed across the micro-pin-fin array. The test module was well insulated to maintain an adiabatic condition. Four maximum mass velocities of 184, 235, 337, and 391 kg/m²s, and a range of vapor qualities for each maximum mass velocity were tested. Measured pressure drop increases drastically with increasing vapor quality. Nine existing twophase pressure drop models and correlations were assessed. The Lockhart-Martinelli correlation for laminar liquid-laminar vapor combination in conjunction with a single-phase friction factor correlation proposed for the present micro-pin-fin array provided the best agreement with the data

    Measurement of the branching fraction and CP content for the decay B(0) -> D(*+)D(*-)

    Get PDF
    This is the pre-print version of the Article. The official published version can be accessed from the links below. Copyright @ 2002 APS.We report a measurement of the branching fraction of the decay B0→D*+D*- and of the CP-odd component of its final state using the BABAR detector. With data corresponding to an integrated luminosity of 20.4  fb-1 collected at the Υ(4S) resonance during 1999–2000, we have reconstructed 38 candidate signal events in the mode B0→D*+D*- with an estimated background of 6.2±0.5 events. From these events, we determine the branching fraction to be B(B0→D*+D*-)=[8.3±1.6(stat)±1.2(syst)]×10-4. The measured CP-odd fraction of the final state is 0.22±0.18(stat)±0.03(syst).This work is supported by DOE and NSF (USA), NSERC (Canada), IHEP (China), CEA and CNRS-IN2P3 (France), BMBF (Germany), INFN (Italy), NFR (Norway), MIST (Russia), and PPARC (United Kingdom). Individuals have received support from the A.P. Sloan Foundation, Research Corporation, and Alexander von Humboldt Foundation

    Measurement of the B0-anti-B0-Oscillation Frequency with Inclusive Dilepton Events

    Get PDF
    The B0B^0-Bˉ0\bar B^0 oscillation frequency has been measured with a sample of 23 million \B\bar B pairs collected with the BABAR detector at the PEP-II asymmetric B Factory at SLAC. In this sample, we select events in which both B mesons decay semileptonically and use the charge of the leptons to identify the flavor of each B meson. A simultaneous fit to the decay time difference distributions for opposite- and same-sign dilepton events gives Δmd=0.493±0.012(stat)±0.009(syst)\Delta m_d = 0.493 \pm 0.012{(stat)}\pm 0.009{(syst)} ps1^{-1}.Comment: 7 pages, 1 figure, submitted to Physical Review Letter

    Measurement of D-s(+) and D-s(*+) production in B meson decays and from continuum e(+)e(-) annihilation at √s=10.6 GeV

    Get PDF
    This is the pre-print version of the Article. The official published version can be accessed from the links below. Copyright @ 2002 APSNew measurements of Ds+ and Ds*+ meson production rates from B decays and from qq̅ continuum events near the Υ(4S) resonance are presented. Using 20.8 fb-1 of data on the Υ(4S) resonance and 2.6 fb-1 off-resonance, we find the inclusive branching fractions B(B⃗Ds+X)=(10.93±0.19±0.58±2.73)% and B(B⃗Ds*+X)=(7.9±0.8±0.7±2.0)%, where the first error is statistical, the second is systematic, and the third is due to the Ds+→φπ+ branching fraction uncertainty. The production cross sections σ(e+e-→Ds+X)×B(Ds+→φπ+)=7.55±0.20±0.34pb and σ(e+e-→Ds*±X)×B(Ds+→φπ+)=5.8±0.7±0.5pb are measured at center-of-mass energies about 40 MeV below the Υ(4S) mass. The branching fractions ΣB(B⃗Ds(*)+D(*))=(5.07±0.14±0.30±1.27)% and ΣB(B⃗Ds*+D(*))=(4.1±0.2±0.4±1.0)% are determined from the Ds(*)+ momentum spectra. The mass difference m(Ds+)-m(D+)=98.4±0.1±0.3MeV/c2 is also measured.This work was supported by DOE and NSF (USA), NSERC (Canada), IHEP (China), CEA and CNRS-IN2P3 (France), BMBF (Germany), INFN (Italy), NFR (Norway), MIST (Russia), and PPARC (United Kingdom). Individuals have received support from the Swiss NSF, A. P. Sloan Foundation, Research Corporation, and Alexander von Humboldt Foundation

    A Study of Time-Dependent CP-Violating Asymmetries and Flavor Oscillations in Neutral B Decays at the Upsilon(4S)

    Get PDF
    We present a measurement of time-dependent CP-violating asymmetries in neutral B meson decays collected with the BABAR detector at the PEP-II asymmetric-energy B Factory at the Stanford Linear Accelerator Center. The data sample consists of 29.7 fb1{\rm fb}^{-1} recorded at the Υ(4S)\Upsilon(4S) resonance and 3.9 fb1{\rm fb}^{-1} off-resonance. One of the neutral B mesons, which are produced in pairs at the Υ(4S)\Upsilon(4S), is fully reconstructed in the CP decay modes J/ψKS0J/\psi K^0_S, ψ(2S)KS0\psi(2S) K^0_S, χc1KS0\chi_{c1} K^0_S, J/ψK0J/\psi K^{*0} (K0KS0π0K^{*0}\to K^0_S\pi^0) and J/ψKL0J/\psi K^0_L, or in flavor-eigenstate modes involving D()π/ρ/a1D^{(*)}\pi/\rho/a_1 and J/ψK0J/\psi K^{*0} (K0K+πK^{*0}\to K^+\pi^-). The flavor of the other neutral B meson is tagged at the time of its decay, mainly with the charge of identified leptons and kaons. The proper time elapsed between the decays is determined by measuring the distance between the decay vertices. A maximum-likelihood fit to this flavor eigenstate sample finds Δmd=0.516±0.016(stat)±0.010(syst)ps1\Delta m_d = 0.516\pm 0.016 {\rm (stat)} \pm 0.010 {\rm (syst)} {\rm ps}^{-1}. The value of the asymmetry amplitude sin2β\sin2\beta is determined from a simultaneous maximum-likelihood fit to the time-difference distribution of the flavor-eigenstate sample and about 642 tagged B0B^0 decays in the CP-eigenstate modes. We find sin2β=0.59±0.14(stat)±0.05(syst)\sin2\beta=0.59\pm 0.14 {\rm (stat)} \pm 0.05 {\rm (syst)}, demonstrating that CP violation exists in the neutral B meson system. (abridged)Comment: 58 pages, 35 figures, submitted to Physical Review
    corecore