1,426 research outputs found

    Changes in the secretory profile of NSCLC-associated fibroblasts after ablative radiotherapy: potential impact on angiogenesis and tumor growth

    Get PDF
    In the context of radiotherapy, collateral effects of ablative ionizing radiation (AIR) on stromal components of tumors remains understudied. In this work, cancer-associated fibroblasts (CAFs) isolated from freshly resected human lung tumors were exposed to AIR (1x18Gy) and analyzed for their release of paracrine factors. Inflammatory mediators and regulators of angiogenesis and tumor growth were analyzed by multiplex protein assays in conditioned medium (CM) from irradiated and non-irradiated CAFs. Additionally, the profile of secreted proteins was examined by proteomics. In functional assays, effects of CAF-CM on proliferative and migratory capacity of lung tumor cells (H-520/H-522) and endothelial cells (HUVECs), and on the tube-forming capacity of endothelial cells was assessed. Our data show that exposure of CAFs to ablative doses of ionizing radiation results in a) down-regulated release of angiogenic factors SDF-1, angiopoietin and thrombospondin-2; b) up-regulated release of growth factor bFGF from most donors, and c) unaffected expression-levels of HGF and inflammatory mediators IL-6, IL-8, IL-1Æ’Ă’ and TNF-ÂŁ. Conditioned medium from irradiated and control CAFs did not affect differently the proliferative or migratory capacity of tumor cells (H-520/H-522), whereas migratory capacity of endothelial HUVEC cells was partially reduced in the presence of irradiated CAF conditioned medium. Overall we conclude that AIR mediates a transformation on the secretory profile of CAFs that could influence the behavior of other cells in the tumor tissue and hence guide to some extent therapeutic outcomes. The downstream consequences of the changes observed in this study merits further investigations

    The Patterns of High-Level Magnetic Activity Occurring on the Surface of V1285 Aql: The OPEA Model of Flares and DFT Models of Stellar Spots

    Full text link
    Statistically analyzing Johnson UBVR observations of V1285 Aql during the three observing seasons, both activity level and behavior of the star are discussed in respect to obtained results. We also discuss the out-of-flare variation due to rotational modulation. Eighty-three flares were detected in the U-band observations of season 2006 . First, depending on statistical analyses using the independent samples t-test, the flares were divided into two classes as the fast and the slow flares. According to the results of the test, there is a difference of about 73 s between the flare-equivalent durations of slow and fast flares. The difference should be the difference mentioned in the theoretical models. Second, using the one-phase exponential association function, the distribution of the flare-equivalent durations versus the flare total durations was modeled. Analyzing the model, some parameters such as plateau, half-life values, mean average of the flare-equivalent durations, maximum flare rise, and total duration times are derived. The plateau value, which is an indicator of the saturation level of white-light flares, was derived as 2.421{\pm}0.058 s in this model, while half-life is computed as 201 s. Analyses showed that observed maximum value of flare total duration is 4641 s, while observed maximum flare rise time is 1817 s. According to these results, although computed energies of the flares occurring on the surface of V1285 Aql are generally lower than those of other stars, the length of its flaring loop can be higher than those of more active stars.Comment: 44 pages, 10 figures, 5 tables, 2011PASP..123..659

    Proton tracking in a high-granularity Digital Tracking Calorimeter for proton CT purposes

    Get PDF
    Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stopping power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stopping power in tissue introduces range uncertainties of the order of 2-3% of the range, uncertainties that are contributing to an increase of the necessary planning margins added to the target volume in a patient. Imaging methods and modalities, such as Dual Energy CT and proton CT, have come into consideration in the pursuit of obtaining an as good as possible estimate of the proton stopping power. In this study, a Digital Tracking Calorimeter is benchmarked for proof-of-concept for proton CT purposes. The Digital Tracking Calorimeteris applied for reconstruction of the tracks and energies of individual high energy protons. The presented prototype forms the basis for a proton CT system using a single technology for tracking and calorimetry. This advantage simplifies the setup and reduces the cost of a proton CT system assembly, and it is a unique feature of the Digital Tracking Calorimeter. Data from the AGORFIRM beamline at KVI-CART in Groningen in the Netherlands and Monte Carlo simulation results are used to in order to develop a tracking algorithm for the estimation of the residual ranges of a high number of concurrent proton tracks. The range of the individual protons can at present be estimated with a resolution of 4%. The readout system for this prototype is able to handle an effective proton frequency of 1 MHz by using 500 concurrent proton tracks in each readout frame, which is at the high end range of present similar prototypes. A future further optimized prototype will enable a high-speed and more accurate determination of the ranges of individual protons in a therapeutic beam.Comment: 21 pages, 8 figure

    A Wave Simulator and Active Heave Compensation Framework for Demanding Offshore Crane Operations

    Get PDF
    Abstract-In this work, a framework is presented that makes it possible to reproduce the challenging operational scenario of controlling offshore cranes via a laboratory setup. This framework can be used for testing different control methods and for training purposes. The system consists of an industrial robot, the Kuka KR 6 R900 SIXX (KR AGILUS) manipulator and a motion platform with three degrees of freedom. This work focuses on the system integration. The motion platform is used to simulate the wave effects, while the robotic arm is controlled by the user with a joystick. The wave contribution is monitored by means of an accelerometer mounted on the platform and it is used as a negative input to the manipulator's control algorithm so that active heave compensation methods can be achieved. Concerning the system architecture, the presented framework is built on open-source software and hardware. The control software is realised by applying strict multi-threading criteria to meet demanding real-time requirements. Related simulations and experimental results are carried out to validate the efficiency of the proposed framework. In particular, it can be certified that this approach allows for an effective risk reduction from both an individual as well as an overall evaluation of the potential harm

    A simulation game for nonlinear control theory education

    Full text link

    The Density of Coronal Plasma in Active Stellar Coronae

    Get PDF
    We have analyzed high-resolution X-ray spectra of a sample of 22 active stars observed with the High Energy Transmission Grating Spectrometer on {\em Chandra} in order to investigate their coronal plasma density. Densities where investigated using the lines of the He-like ions O VII, Mg XI, and Si XIII. While Si XIII lines in all stars of the sample are compatible with the low-density limit, Mg XI lines betray the presence of high plasma densities (>1012> 10^{12} cm−3^{-3}) for most of the sources with higher X-ray luminosity (>1030> 10^{30} erg/s); stars with higher LXL_X and LX/LbolL_X/L_{bol} tend to have higher densities at high temperatures. Ratios of O VII lines yield much lower densities of a few 101010^{10} cm−3^{-3}, indicating that the ``hot'' and ``cool'' plasma resides in physically different structures. Our findings imply remarkably compact coronal structures, especially for the hotter plasma emitting the Mg XI lines characterized by coronal surface filling factor, fMgXIf_{MgXI}, ranging from 10−410^{-4} to 10−110^{-1}, while we find fOVIIf_{OVII} values from a few 10−310^{-3} up to ∌1\sim 1 for the cooler plasma emitting the O VII lines. We find that fOVIIf_{OVII} approaches unity at the same stellar surface X-ray flux level as solar active regions, suggesting that these stars become completely covered by active regions. At the same surface flux level, fMgXIf_{MgXI} is seen to increase more sharply with increasing surface flux. These results appear to support earlier suggestions that hot 10710^7 K plasma in active coronae arises from flaring activity, and that this flaring activity increases markedly once the stellar surface becomes covered with active regions.Comment: 53 pages, 19 figures, accepted for publication in Astrophysical Journal. A version of the paper with higher quality figures is available from http://www.astropa.unipa.it/Library/preprint.htm

    Anomaly in the stability limit of liquid helium 3

    Full text link
    We propose that the liquid-gas spinodal line of helium 3 reaches a minimum at 0.4 K. This feature is supported by our cavitation measurements. We also show that it is consistent with extrapolations of sound velocity measurements. Speedy [J. Phys. Chem. 86, 3002 (1982)] previously proposed this peculiar behavior for the spinodal of water and related it to a change in sign of the expansion coefficient alpha, i. e. a line of density maxima. Helium 3 exhibits such a line at positive pressure. We consider its extrapolation to negative pressure. Our discussion raises fundamental questions about the sign of alpha in a Fermi liquid along its spinodal.Comment: 5 pages, 3 figure

    New periodic variable stars coincident with ROSAT sources discovered using SuperWASP

    Get PDF
    We present optical lightcurves of 428 periodic variable stars coincident with ROSAT X-ray sources, detected using the first run of the SuperWASP photometric survey. Only 68 of these were previously recognised as periodic variables. A further 30 of these objects are previously known pre-main sequence stars, for which we detect a modulation period for the first time. Amongst the newly identified periodic variables, many appear to be close eclipsing binaries, their X-ray emission is presumably the result of RS CVn type behaviour. Others are probably BY Dra stars, pre-main sequence stars and other rapid rotators displaying enhanced coronal activity. A number of previously catalogued pulsating variables (RR Lyr stars and Cepheids) coincident with X-ray sources are also seen, but we show hat these are likely to be misclassifications. We identify four objects which are probable low mass eclipsing binary stars, based on their very red colour and light curve morphology

    Microtubules in Bacteria: Ancient Tubulins Build a Five-Protofilament Homolog of the Eukaryotic Cytoskeleton

    Get PDF
    Microtubules play crucial roles in cytokinesis, transport, and motility, and are therefore superb targets for anti-cancer drugs. All tubulins evolved from a common ancestor they share with the distantly related bacterial cell division protein FtsZ, but while eukaryotic tubulins evolved into highly conserved microtubule-forming heterodimers, bacterial FtsZ presumably continued to function as single homopolymeric protofilaments as it does today. Microtubules have not previously been found in bacteria, and we lack insight into their evolution from the tubulin/FtsZ ancestor. Using electron cryomicroscopy, here we show that the tubulin homologs BtubA and BtubB form microtubules in bacteria and suggest these be referred to as “bacterial microtubules” (bMTs). bMTs share important features with their eukaryotic counterparts, such as straight protofilaments and similar protofilament interactions. bMTs are composed of only five protofilaments, however, instead of the 13 typical in eukaryotes. These and other results suggest that rather than being derived from modern eukaryotic tubulin, BtubA and BtubB arose from early tubulin intermediates that formed small microtubules. Since we show that bacterial microtubules can be produced in abundance in vitro without chaperones, they should be useful tools for tubulin research and drug screening
    • 

    corecore