8 research outputs found

    Second-generation colon capsule endoscopy compared with colonoscopy

    Get PDF
    Colon capsule endoscopy (CCE) represents a noninvasive technology that allows visualization of the colon without requiring sedation and air insufflation. A second-generation colon capsule endoscopy system (PillCam Colon 2) (CCE-2) was developed to increase sensitivity for colorectal polyp detection compared with the first-generation system. OBJECTIVE: To assess the feasibility, accuracy, and safety of CCE-2 in a head-to-head comparison with colonoscopy. DESIGN AND SETTING: Prospective, multicenter trial including 8 European sites. PATIENTS: This study involved 117 patients (mean age 60 years). Data from 109 patients were analyzed. INTERVENTION: CCE-2 was prospectively compared with conventional colonoscopy as the criterion standard for the detection of colorectal polyps that are >/=6 mm or masses in a cohort of patients at average or increased risk of colorectal neoplasia. Colonoscopy was independently performed within 10 hours after capsule ingestion or on the next day. MAIN OUTCOME MEASUREMENTS: CCE-2 sensitivity and specificity for detecting patients with polyps >/=6 mm and >/=10 mm were assessed. Capsule-positive but colonoscopy-negative cases were counted as false positive. Capsule excretion rate, level of bowel preparation, and rate of adverse events also were assessed. RESULTS: Per-patient CCE-2 sensitivity for polyps >/=6 mm and >/=10 mm was 84% and 88%, with specificities of 64% and 95%, respectively. All 3 invasive carcinomas were detected by CCE-2. The capsule excretion rate was 88% within 10 hours. Overall colon cleanliness for CCE-2 was adequate in 81% of patients. LIMITATIONS: Not unblinding the CCE-2 results at colonoscopy; heterogenous patient population; nonconsecutive patients. CONCLUSION: In this European, multicenter study, CCE-2 appeared to have a high sensitivity for the detection of clinically relevant polypoid lesions, and it might be considered an adequate tool for colorectal imaging

    Factors Associated with Polyp Detection Rate in European Colonoscopy Practice : Findings of The European Colonoscopy Quality Investigation (ECQI) Group

    Get PDF
    BACKGROUND: The European Colonoscopy Quality Investigation (ECQI) Group aims to raise awareness for improvement in colonoscopy standards across Europe. We analysed data collected on a sample of procedures conducted across Europe to evaluate the achievement of the polyp detection rate (PDR) target. We also investigated factors associated with PDR, in the hope of establishing areas that could lead to a quality improvement. METHODS: 6445 form completions from 12 countries between 2 June 2016 and 30 April 2018 were considered for this analysis. We performed an exploratory analysis looking at PDR according to European Society of Gastrointestinal Endoscopy (ESGE) definition. Stepwise multivariable logistic regression analysis was conducted to determine the most influential associated factors after adjusting for the other pre-specified variables. RESULTS: In our sample there were 3365 screening and diagnostic procedures performed in those over 50 years. The PDR was 40.5%, which is comparable with the ESGE minimum standard of 40%. The variables found to be associated with PDR were in descending order: use of high-definition equipment, body mass index (BMI), patient gender, age group, and the reason for the procedure. Use of HD equipment was associated with a significant increase in the reporting of flat lesions (14.3% vs. 5.7%, p < 0.0001) and protruded lesions (34.7% vs. 25.4%, p < 0.0001). CONCLUSIONS: On average, the sample of European practice captured by the ECQI survey meets the minimum PDR standard set by the ESGE. Our findings support the ESGE recommendation for routine use of HD colonoscopy.publishedVersionPeer reviewe

    Colonoscopy quality across Europe: a report of the European Colonoscopy Quality Investigation (ECQI) Group

    No full text
    Background and study aims  The European Colonoscopy Quality Investigation (ECQI) Group comprises expert colonoscopists and investigators with the aim of raising colonoscopy standards. We assessed the levels of monitoring and achievement of European Society of Gastrointestinal Endoscopy (ESGE) performance measures (PMs) across Europe using responses to the ECQI questionnaires. Methods  The questionnaire comprises three forms: institution and practitioner questionnaires are completed once; a procedure questionnaire is completed on multiple occasions for individual total colonoscopies. ESGE PMs were approximated as closely as possible from the data collected via the procedure questionnaire. Procedure data could provide rate of adequate bowel preparation, cecal intubation rate (CIR), withdrawal time, polyp detection rate (PDR), and tattooing resection sites. Results  We evaluated ECQI questionnaire data collected between June 2016 and April 2018, comprising 91 practitioner and 52 institution questionnaires. A total of 6445 completed procedure forms were received. Institution and practitioner responses indicate that routine recording of PMs is not widespread: adenoma detection rate (ADR) is routinely recorded in 29 % of institutions and by 34 % of practitioners; PDR by 42 % and 47 %, CIR by 62 % and 64 %, bowel preparation quality by 56 % and 76 %, respectively. Procedure data showed a rate of adequate bowel preparation of 84.2 %, CIR 73.4 %, PDR 40.5 %, mean withdrawal time 7.8 minutes and 12.2 % of procedures with possible removal of a non-pedunculated lesion ≄ 20 mm reporting tattooing. Conclusions  Our findings clearly show areas in need of quality improvement and the importance of promoting quality monitoring throughout the colonoscopy procedure

    Factors Associated with Withdrawal Time in European Colonoscopy Practice : Findings of the European Colonoscopy Quality Investigation (ECQI) Group

    Get PDF
    The European Colonoscopy Quality Investigation (ECQI) Group aims to raise awareness for improvement in colonoscopy standards across Europe. We analyzed data collected on a sample of procedures conducted across Europe to evaluate the achievement of the European Society of Gastrointestinal Endoscopy (ESGE) mean withdrawal time (WT) target. We also investigated factors associated with WT, in the hope of establishing areas that could lead to a quality improvement. Methods: 6445 form completions from 12 countries between 2 June 2016 and 30 April 2018 were considered for this analysis. We performed an exploratory analysis looking at WT according to the ESGE definition. Stepwise multivariable logistic regression analysis was conducted to determine the most influential associated factors after adjusting for the other pre-specified variables. Results: In 1150 qualifying colonoscopies, the mean WT was 7.8 min. Stepwise analysis, including 587 procedures where all inputs were known, found that the variables most associated with mean WT were a previous total colonoscopy in the last five years (p = 0.0011) and the time of day the colonoscopy was performed (p = 0.0192). The main factor associated with a WT 10 min, along with a previous colonoscopy. Conclusions: On average, the sample of European practice captured by the ECQI survey met the minimum standard set by the ESGE. How-ever, there was variation and potential for improvement

    Colon capsule versus CT colonography in patients with incomplete colonoscopy: a prospective, comparative trial

    No full text
    In case of incomplete colonoscopy, several radiologic methods have traditionally been used, but more recently, capsule endoscopy was also shown to be accurate. Aim of this study was to compare colon capsule endoscopy (CCE) and CT colonography (CTC) in a prospective cohort of patients with incomplete colonoscopy

    Second-generation colon capsule endoscopy compared with colonoscopy

    No full text
    Colon capsule endoscopy (CCE) represents a noninvasive technology that allows visualization of the colon without requiring sedation and air insufflation. A second-generation colon capsule endoscopy system (PillCam Colon 2) (CCE-2) was developed to increase sensitivity for colorectal polyp detection compared with the first-generation system. OBJECTIVE: To assess the feasibility, accuracy, and safety of CCE-2 in a head-to-head comparison with colonoscopy. DESIGN AND SETTING: Prospective, multicenter trial including 8 European sites. PATIENTS: This study involved 117 patients (mean age 60 years). Data from 109 patients were analyzed. INTERVENTION: CCE-2 was prospectively compared with conventional colonoscopy as the criterion standard for the detection of colorectal polyps that are >/=6 mm or masses in a cohort of patients at average or increased risk of colorectal neoplasia. Colonoscopy was independently performed within 10 hours after capsule ingestion or on the next day. MAIN OUTCOME MEASUREMENTS: CCE-2 sensitivity and specificity for detecting patients with polyps >/=6 mm and >/=10 mm were assessed. Capsule-positive but colonoscopy-negative cases were counted as false positive. Capsule excretion rate, level of bowel preparation, and rate of adverse events also were assessed. RESULTS: Per-patient CCE-2 sensitivity for polyps >/=6 mm and >/=10 mm was 84% and 88%, with specificities of 64% and 95%, respectively. All 3 invasive carcinomas were detected by CCE-2. The capsule excretion rate was 88% within 10 hours. Overall colon cleanliness for CCE-2 was adequate in 81% of patients. LIMITATIONS: Not unblinding the CCE-2 results at colonoscopy; heterogenous patient population; nonconsecutive patients. CONCLUSION: In this European, multicenter study, CCE-2 appeared to have a high sensitivity for the detection of clinically relevant polypoid lesions, and it might be considered an adequate tool for colorectal imaging
    corecore