75 research outputs found

    Climate Smart coffee in Guatemala

    Get PDF
    Guatemala is the second-largest coffee producer in Central America after Honduras. The coffee sector is a driver of the rural economy, providing incomes for over 122000 farmers, 98% of whom are smallholders. Guatemalan coffee production generates half a million jobs in the rural economy, nearly 10% of the national active labor force. Approximately 3.3 million 60kg bags of coffee beans are produced annually. Shade grown high-quality arabica coffee for international markets is the norm in the fields of the caficultores (coffee farmers). Consumer demand has driven the growth of exports of Strictly High Bean, the highest quality produced in Guatemala which accounts for approximately 83% of exports. The total value of exports makes up 14% of the total export value or 651m in USD. It is the second most important agricultural product after sugar in terms of foreign revenue earnings. Current coffee production areas are projected to experience a gradual increase in temperatures towards more extreme ranges as well as periods of drought and heavy rainfall. Annual temperatures are projected to increase by 1.7ÂșC-2.0ÂșC and total annual precipitation is projected to decrease between 0.8% in the southern coast and 6% in the border between the north and northeastern regions. The climate-smart agriculture (CSA) concept reflects an ambition to improve the integration of agriculture development and climate responsiveness. It aims to achieve food security and broader development goals under a changing climate and increasing food demand. CSA initiatives sustainably increase productivity, enhance resilience, and reduce/remove greenhouse gases (GHGs). While the concept is new and still evolving, many of the practices that make up CSA already exist worldwide and are used by farmers to cope with various production risks. Mainstreaming Climate Smart Coffee (CSC) requires critical stocktaking of the sector fundamentals, already evident and projected climatic developments relevant to coffee production and promising practices for the future, and of institutional and financial enablers for CSC adoption. This CSC profile provides a snapshot of a developing baseline created to initiate discussion, both within countries and globally, about entry points for investing in CSC at scale

    The establishment of a WHO Reference Reagent for anti-malaria (Plasmodium falciparum) human serum

    Get PDF
    BACKGROUND: At a World Health Organization (WHO) sponsored meeting it was concluded that there is an urgent need for a reference preparation that contains antibodies against malaria antigens in order to support serology studies and vaccine development. It was proposed that this reference would take the form of a lyophilized serum or plasma pool from a malaria-endemic area. In response, an immunoassay standard, comprising defibrinated human plasma has been prepared and evaluated in a collaborative study. RESULTS: A pool of human plasma from a malaria endemic region was collected from 140 single plasma donations selected for reactivity to Plasmodium falciparum apical membrane antigen-1 (AMA-1) and merozoite surface proteins (MSP-119, MSP-142, MSP-2 and MSP-3). This pool was defibrinated, filled and freeze dried into a single batch of ampoules to yield a stable source of naturally occurring antibodies to P. falciparum. The preparation was evaluated by an enzyme-linked immunosorbent assay (ELISA) in a collaborative study with sixteen participants from twelve different countries. This anti-malaria human serum preparation (NIBSC Code: 10/198) was adopted by the WHO Expert Committee on Biological Standardization (ECBS) in October 2014, as the first WHO reference reagent for anti-malaria (Plasmodium falciparum) human serum with an assigned arbitrary unitage of 100 units (U) per ampoule. CONCLUSION: Analysis of the reference reagent in a collaborative study has demonstrated the benefit of this preparation for the reduction in inter- and intra-laboratory variability in ELISA. Whilst locally sourced pools are regularly use for harmonization both within and between a few laboratories, the presence of a WHO-endorsed reference reagent should enable optimal harmonization of malaria serological assays either by direct use of the reference reagent or calibration of local standards against this WHO reference. The intended uses of this reference reagent, a multivalent preparation, are (1) to allow cross-comparisons of results of vaccine trials performed in different centres/with different products; (2) to facilitate standardization and harmonization of immunological assays used in epidemiology research; and (3) to allow optimization and validation of immunological assays used in malaria vaccine development

    Evaluation of a standardised Vi poly-l-lysine ELISA for serology of Vi capsular polysaccharide antibodies

    Get PDF
    Typhoid vaccines based on protein-conjugated capsular Vi polysaccharide (TCVs) prevent typhoid in infants and young children. Analysis of the serum anti-Vi IgG response following immunisation against typhoid confirms the immunogenicity of TCVs and forms an important part of the pathway to licensing. Comparative studies could expedite the licencing process, and the availability of a standardised ELISA method alongside the 1st International Standard (IS) 16/138 for anti-typhoid capsular Vi polysaccharide IgG (human) will facilitate this process. To this end, a non-commercial ELISA based on a coat of Vi and poly-l-lysine (Vi-PLL ELISA) was evaluated by 10 laboratories. Eight serum samples, including IS 16/138, were tested in the standardised Vi-PLL ELISA (n = 10), a commercial Vi ELISA (n = 3) and a biotinylated Vi ELISA (n = 1). Valid estimates of potencies relative to IS 16/138 were obtained for all samples in the Vi-PLL ELISA and the commercial ELISA, with good repeatability and reproducibility evident from the study results and concordant estimates obtained by the two ELISA methods. The study demonstrates that the Vi-PLL ELISA can be used in clinical trial studies to determine the immunogenicity of TCVs

    Development and Assessment of a Pooled Serum as Candidate Standard to Measure Influenza A Virus Group 1 Hemagglutinin Stalk-Reactive Antibodies

    Get PDF
    The stalk domain of the hemagglutinin has been identified as a target for induction of protective antibody responses due to its high degree of conservation among numerous influenza subtypes and strains. However, current assays to measure stalk-based immunity are not standardized. Hence, harmonization of assay readouts would help to compare experiments conducted in different laboratories and increase confidence in results. Here, serum samples from healthy individuals (n = 110) were screened using a chimeric cH6/1 hemagglutinin enzyme-linked immunosorbent assay (ELISA) that measures stalk-reactive antibodies. We identified samples with moderate to high IgG anti-stalk antibody levels. Likewise, screening of the samples using the mini-hemagglutinin (HA) headless construct #4900 and analysis of the correlation between the two assays confirmed the presence and specificity of anti-stalk antibodies. Additionally, samples were characterized by a cH6/1N5 virus-based neutralization assay, an antibody-dependent cell-mediated cytotoxicity (ADCC) assay, and competition ELISAs, using the stalk-reactive monoclonal antibodies KB2 (mouse) and CR9114 (human). A “pooled serum” (PS) consisting of a mixture of selected serum samples was generated. The PS exhibited high levels of stalk-reactive antibodies, had a cH6/1N5-based neutralization titer of 320, and contained high levels of stalk-specific antibodies with ADCC activity. The PS, along with blinded samples of varying anti-stalk antibody titers, was distributed to multiple collaborators worldwide in a pilot collaborative study. The samples were subjected to different assays available in the different laboratories, to measure either binding or functional properties of the stalk-reactive antibodies contained in the serum. Results from binding and neutralization assays were analyzed to determine whether use of the PS as a standard could lead to better agreement between laboratories. The work presented here points the way towards the development of a serum standard for antibodies to the HA stalk domain of phylogenetic group 1

    Establishment of the World Health Organization First International Standard for Factor XII, Plasma, Human

    No full text
    Until recently, the role of factor XII (FXII) in hemostasis was not considered to be important since patients with FXII deficiency do not present with bleeding. The activation of FXII by agents including mast cells and platelet polyphosphates suggests that it may have a role in thrombogenesis. The inhibition of FXII therefore presents an option for antithrombotic therapy, and antibodies and inhibitors are already in development. Assays for FXII will be required to support these technologies, and an international standard (IS) for FXII would be useful for the development of these methods and for the clinical monitoring of patients. The purpose of this study was to develop an IS for FXII, with values for functional activity (FXII:C) and antigen (FXII:Ag). Double-spun normal plasma was pooled, filled into siliconized glass ampoules, and freeze-dried to prepare the candidate material. Data from 20 laboratories using the one-stage clotting assay were used to assign the functional activity value in units (u). The antigen value was calculated using data from eight laboratories that carried out antigen assays. Each laboratory was requested to collect two local normal plasma pools. Units of activity and antigen were calculated relative to these pools, as is usual for new coagulation factor analytes. The amount of activity or antigen in 1 ml of normal plasma from each pool was taken to be 1 unit. A total of 566 donors were used across the pools for the FXII:C study and 216 donors for the FXII:Ag study. The overall geometric mean per ampoule for FXII:C was 0.86 u and for FXII:Ag was 0.80 u. The inter-laboratory variation was 10 and 11%, respectively (expressed as the geometric coefficient of variation). Based on these data, the candidate was deemed suitable for use as an IS for FXII. In 2017, the candidate was established by the World Health Organization (WHO) Expert Committee on Biological Standardization as the WHO first IS for blood coagulation FXII, Plasma (National Institute for Biological Standards and Control code 15/180). The values assigned were 0.86 international units (IU) of functional activity (FXII:C) per ampoule and 0.80 IU/ampoule of antigen (FXII:Ag)
    • 

    corecore