1,428 research outputs found

    Single-session anodal transcranial direct current stimulation to enhance sport-specific performance in athletes: A systematic review and meta-analysis

    Get PDF
    BackgroundTranscranial direct current stimulation (tDCS) has emerged as a promising and feasible method to improve motor performance in healthy and clinical populations. However, the potential of tDCS to enhance sport-specific motor performance in athletes remains elusive.ObjectiveWe aimed at analyzing the acute effects of a single anodal tDCS session on sport-specific motor performance changes in athletes compared to sham.MethodsA systematic review and meta-analysis was conducted in the electronic databases PubMed, Web of Science, and SPORTDiscus. The meta-analysis was performed using an inverse variance method and a random-effects model. Additionally, two subgroup analyses were conducted (1) depending on the stimulated brain areas (primary motor cortex (M1), temporal cortex (TC), prefrontal cortex (PFC), cerebellum (CB)), and (2) studies clustered in subgroups according to different sports performance domains (endurance, strength, visuomotor skill).ResultsA total number of 19 studies enrolling a sample size of 258 athletes were deemed eligible for inclusion. Across all included studies, a significant moderate standardized mean difference (SMD) favoring anodal tDCS to enhance sport-specific motor performance could be observed. Subgroup analysis depending on cortical target areas of tDCS indicated a significant moderate SMD in favor of anodal tDCS compared to sham for M1 stimulation.ConclusionA single anodal tDCS session can lead to performance enhancement in athletes in sport-specific motor tasks. Although no definitive conclusions can be drawn regarding the modes of action as a function of performance domain or stimulation site, these results imply intriguing possibilities concerning sports performance enhancement through anodal M1 stimulation

    Concurrent anodal transcranial direct-current stimulation and motor task to influence sensorimotor cortex activation

    Get PDF
    Functional targeting with anodal high-definition transcranial direct current stimulation (HD-atDCS) of involved brain areas during performance of a motor task (online) may facilitate sensorimotor cortex neuroplasticity compared to performing the motor task after HD-atDCS (offline). The aim of this study was to employ functional near-infrared spectroscopy to compare the time course of motor task-related changes in sensorimotor cortex activation between online and offline HD-atDCS. We hypothesized that online HD-atDCS would have a greater effect on task-related sensorimotor cortex activation than offline HD-atDCS. In a within-subject sham controlled and randomized study design, 9 healthy participants underwent 3 HD-atDCS sessions (online, offline and sham) targeting the left sensorimotor cortex separated by 1 week. Functional near-infrared spectroscopy hemodynamic changes were measured from the left sensorimotor cortex during a simple finger opposition motor task before (Pre), immediately (T1) and 30 min after (T2) each session. The movement rates were not different between (online, offline, sham) or within (Pre, T1, T2) sessions. At T2, online HD-atDCS was associated with a significant increase (large effect size) in sensorimotor cortex activation (Hedges g = 1.01, p<0.001) when compared to sham; there was a nonsignificant trend to increase activation between offline and sham (Hedges g = 0.52, p=0.05) and between online and offline (Hedges g = 0.53, p=0.06). Concurrent application of HD-atDCS during a motor task may produce larger sensorimotor cortex activation than sequential application

    Ipsilateral M1 transcranial direct current stimulation increases excitability of the contralateral M1 during an active motor task: Implications for stroke rehabilitation

    Get PDF
    IntroductionAnodal transcranial direct current stimulation (a-tDCS) of the primary motor cortex (M1) elicits an increase in cortical excitability that outlasts the period of stimulation. However, little is known about effects of a-tDCS on the contralateral M1 during and after ipsilateral M1 stimulation. Therefore, we investigated the changes in corticospinal excitability and inhibition of the left M1 during and after 20min of a-tDCS to the right M1.Material and methodsEight healthy participants received real (2mA) and SHAM a-tDCS to the right M1 randomized across 2 testing sessions. Single- and paired-pulse transcranial magnetic stimulation (TMS) was applied to the left M1 to measure changes motor-evoked potential (MEP) amplitude from the right extensor carpi radialis (ECR) at 130% of resting and active motor threshold, cortical silent period (CSP) and short-interval cortical inhibition (SICI). Active motor threshold was measured during a wrist extension contraction that was less than 5% of maximal electromyographic activation of the ECR. TMS measurements were recorded at baseline, every 5min for 20min during and 10min after a-tDCS.ResultsThe results showed a significant (P<0.05) increase in left M1 MEP amplitude and reduction in CSP duration during (10 and 15min) and after (immediately and 10min post) a-tDCS to the right M1, only during the active motor task. A significant reduction (P<0.05) in SICI during the active task was also found immediately and 10min post a-tDCS. No significant changes in MEP amplitude, CSP and SICI were observed in the resting or active task during SHAM tDCS.DiscussionThe increase in left M1 MEP amplitude and reduction in CSP and SICI during and after 20min of right M1 a-tDCS is most likely to be attributed to a reduction in interhemispheric inhibition that is modulated by a-tDCS during the performance of an active task. Our findings may have significant implications for stroke rehabilitation whereby the application of a-tDCS on the contralesional M1 during neurorehabilitation of the paretic limb may be beneficial for inducing neuroplasticity of the ipsilesional M1 to improve motor function

    Different Hemodynamic Responses of the Primary Motor Cortex Accompanying Eccentric and Concentric Movements: A Functional NIRS Study

    Get PDF
    The literature contains limited evidence on how our brains control eccentric movement. A higher activation is expected in the contralateral motor cortex (M1) but consensus has not yet been reached. Therefore, the present study aimed to compare patterns of M1 activation between eccentric and concentric movements. Nine healthy participants performed in a randomized order three sets of five repetitions of eccentric or concentric movement with the dominant elbow flexors over a range of motion of 60◦ at two velocities (30◦/s and 60◦/s). The tests were carried out using a Biodex isokinetic dynamometer with the forearm supported in the horizontal plane. The peak torque values were not significantly different between concentric and eccentric movements (p = 0.42). Hemodynamic responses of the contralateral and ipsilateral M1 were measured with a near-infrared spectroscopy system (Oxymon MkIII, Artinis). A higher contralateral M1 activity was found during eccentric movements (p = 0.04, η2 = 0.47) and at the velocity of 30◦/s (p = 0.039, η2 = 0.48). These preliminary findings indicate a specific control mechanism in the contralateral M1 to produce eccentric muscle actions at the angular velocities investigated, although the role of other brain areas in the motor control network cannot be excluded

    Performance of the EUDET-type beam telescopes

    Full text link
    Test beam measurements at the test beam facilities of DESY have been conducted to characterise the performance of the EUDET-type beam telescopes originally developed within the EUDET project. The beam telescopes are equipped with six sensor planes using MIMOSA26 monolithic active pixel devices. A programmable Trigger Logic Unit provides trigger logic and time stamp information on particle passage. Both data acquisition framework and offline reconstruction software packages are available. User devices are easily integrable into the data acquisition framework via predefined interfaces. The biased residual distribution is studied as a function of the beam energy, plane spacing and sensor threshold. Its standard deviation at the two centre pixel planes using all six planes for tracking in a 6\,GeV electron/positron-beam is measured to be (2.88\,\pm\,0.08)\,\upmu\meter.Iterative track fits using the formalism of General Broken Lines are performed to estimate the intrinsic resolution of the individual pixel planes. The mean intrinsic resolution over the six sensors used is found to be (3.24\,\pm\,0.09)\,\upmu\meter.With a 5\,GeV electron/positron beam, the track resolution halfway between the two inner pixel planes using an equidistant plane spacing of 20\,mm is estimated to (1.83\,\pm\,0.03)\,\upmu\meter assuming the measured intrinsic resolution. Towards lower beam energies the track resolution deteriorates due to increasing multiple scattering. Threshold studies show an optimal working point of the MIMOSA26 sensors at a sensor threshold of between five and six times their RMS noise. Measurements at different plane spacings are used to calibrate the amount of multiple scattering in the material traversed and allow for corrections to the predicted angular scattering for electron beams

    Focal Hemodynamic Responses in the Stimulated Hemisphere During High-Definition Transcranial Direct Current Stimulation

    Get PDF
    OBJECTIVE: High-definition transcranial direct current stimulation (HD-tDCS) using a 4 × 1 electrode montage has been previously shown using modeling and physiological studies to constrain the electric field within the spatial extent of the electrodes. The aim of this proof-of-concept study was to determine if functional near-infrared spectroscopy (fNIRS) neuroimaging can be used to determine a hemodynamic correlate of this 4 × 1 HD-tDCS electric field on the brain. MATERIALS AND METHODS: In a three session cross-over study design, 13 healthy males received one sham (2 mA, 30 sec) and two real (HD-tDCS-1 and HD-tDCS-2, 2 mA, 10 min) anodal HD-tDCS targeting the left M1 via a 4 × 1 electrode montage (anode on C3 and 4 return electrodes 3.5 cm from anode). The two real HD-tDCS sessions afforded a within-subject replication of the findings. fNIRS was used to measure changes in brain hemodynamics (oxygenated hemoglobin integral-O2 Hbint ) during each 10 min session from two regions of interest (ROIs) in the stimulated left hemisphere that corresponded to "within" (Lin ) and "outside" (Lout ) the spatial extent of the 4 × 1 electrode montage, and two corresponding ROIs (Rin and Rout ) in the right hemisphere. RESULTS: The ANOVA showed that both real anodal HD-tDCS compared to sham induced a significantly greater O2 Hbint in the Lin than Lout ROIs of the stimulated left hemisphere; while there were no significant differences between the real and sham sessions for the right hemisphere ROIs. Intra-class correlation coefficients showed "fair-to-good" reproducibility for the left stimulated hemisphere ROIs. CONCLUSIONS: The greater O2 Hbint "within" than "outside" the spatial extent of the 4 × 1 electrode montage represents a hemodynamic correlate of the electrical field distribution, and thus provides a prospective reliable method to determine the dose of stimulation that is necessary to optimize HD-tDCS parameters in various applications

    Cognitive benefits of exercise interventions: an fMRI activation likelihood estimation meta-analysis

    Get PDF
    Despite a growing number of functional MRI studies reporting exercise-induced changes during cognitive processing, a systematic determination of the underlying neurobiological pathways is currently lacking. To this end, our neuroimaging meta-analysis included 20 studies and investigated the influence of physical exercise on cognition-related functional brain activation. The overall meta-analysis encompassing all experiments revealed physical exercise-induced changes in the left parietal lobe during cognitive processing. Subgroup analysis further revealed that in the younger-age group (&lt; 35&nbsp;years old) physical exercise induced more widespread changes in the right hemisphere, whereas in the older-age group (≥ 35&nbsp;years old) exercise-induced changes were restricted to the left parietal lobe. Subgroup analysis for intervention duration showed that shorter exercise interventions induced changes in regions connected with frontoparietal and default mode networks, whereas regions exhibiting effects of longer interventions connected with frontoparietal and dorsal attention networks. Our findings suggest that physical exercise interventions lead to changes in functional activation patterns primarily located in precuneus and associated with frontoparietal, dorsal attention and default mode networks. © 2021, The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature
    corecore