116 research outputs found

    Diagnosis and Management of Iliac Artery Endofibrosis: Results of a Delphi Consensus Study

    Get PDF
    Objective Iliac endofibrosis is a rare condition that may result in a reduction of blood flow to the lower extremity in young, otherwise healthy individuals. The data to inform everyday clinical management are weak and therefore a Delphi consensus methodology was used to explore areas of consensus and disagreement concerning the diagnosis and management of patients with suspected iliac endofibrosis. Methods A three-round Delphi questionnaire approach was used among vascular surgeons, sports physicians, sports scientists, radiologists, and clinical vascular scientists with experience of treating this condition to explore diagnosis and clinical management issues for patients with suspected iliac artery endofibrosis. Analysis is based on 18 responses to round 2 and 14 responses to round 3, with agreement reported when 70% of respondents were in agreement. Results Initially there was agreement on the typical symptoms at presentation and the need for an exercise test in the diagnosis. Round 3 clarified that duplex ultrasound was a useful tool in the diagnosis of endofibrosis. There was consensus on the most appropriate type of surgery (endarterectomy and vein patch) and that endovascular interventions were inadvisable. The final round helped to inform aspects of the natural history and post-operative surveillance. Progression of the disease was likely with continued exercise but cessation may prevent progression. Surveillance after surgery is generally recommended yearly with at least a clinical assessment. Conclusions There is broad agreement about the presenting symptoms and the investigations required to confirm (or exclude) the diagnosis of iliac endofibrosis. There was consensus on the surgical approach to repair. Disagreement existed about the specific diagnostic criteria that should be applied during non-invasive testing and about post-operative care and resumption of exercise

    Ceramide-induced integrated stress response overcomes Bcl-2 inhibitor resistance in acute myeloid leukemia.

    Get PDF
    Inducing cell death by the sphingolipid ceramide is a potential anti-cancer strategy, but the underlying mechanisms remain poorly defined. Here, we show that triggering accumulation of ceramide in acute myeloid leukaemia (AML) cells by inhibition of sphingosine kinase induces an apoptotic integrated stress response (ISR) through protein kinase R-mediated activation of the master transcription factor ATF4. This leads to transcription of the BH3-only protein, Noxa, and degradation of the pro-survival Mcl-1 protein on which AML cells are highly dependent on for survival. Targeting this novel ISR pathway in combination with the Bcl-2 inhibitor venetoclax synergistically killed primary AML blasts, including those with venetoclax-resistant mutations, as well as immunophenotypic leukemic stem cells, and reduced leukemic engraftment in patient-derived AML xenografts. Collectively, these findings provide mechanistic insight into the anti-cancer effects of ceramide and pre-clinical evidence for new approaches to augment Bcl-2 inhibition in the therapy of AML and other cancers with high Mcl-1 dependency.Alexander C. Lewis, Victoria S. Pope, Melinda N. Tea, Manjun Li, Gus O. Nwosu, Thao M. Nguyen, Craig T. Wallington-Beddoe, Paul A. B. Moretti, Dovile Anderson, Darren J. Creek, Maurizio Costabile, Saira R. Ali, Chloe A. L. Thompson-Peach, B. Kate Dredge, Andrew G. Bert, Gregory J. Goodall, Paul G. Ekert, Anna L. Brown, Richard D'Andrea, Nirmal Robinson, Melissa R. Pitman, Daniel Thomas, David M. Ross, Briony L. Gliddon, Jason A. Powell, and Stuart M. Pitso

    Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

    Get PDF
    The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR

    Relationship of edge localized mode burst times with divertor flux loop signal phase in JET

    Get PDF
    A phase relationship is identified between sequential edge localized modes (ELMs) occurrence times in a set of H-mode tokamak plasmas to the voltage measured in full flux azimuthal loops in the divertor region. We focus on plasmas in the Joint European Torus where a steady H-mode is sustained over several seconds, during which ELMs are observed in the Be II emission at the divertor. The ELMs analysed arise from intrinsic ELMing, in that there is no deliberate intent to control the ELMing process by external means. We use ELM timings derived from the Be II signal to perform direct time domain analysis of the full flux loop VLD2 and VLD3 signals, which provide a high cadence global measurement proportional to the voltage induced by changes in poloidal magnetic flux. Specifically, we examine how the time interval between pairs of successive ELMs is linked to the time-evolving phase of the full flux loop signals. Each ELM produces a clear early pulse in the full flux loop signals, whose peak time is used to condition our analysis. The arrival time of the following ELM, relative to this pulse, is found to fall into one of two categories: (i) prompt ELMs, which are directly paced by the initial response seen in the flux loop signals; and (ii) all other ELMs, which occur after the initial response of the full flux loop signals has decayed in amplitude. The times at which ELMs in category (ii) occur, relative to the first ELM of the pair, are clustered at times when the instantaneous phase of the full flux loop signal is close to its value at the time of the first ELM

    Habilidades e avaliação de executivos

    Full text link

    Operator-controlled Imaging Significantly Reduces Radiation Exposure during EVAR

    Get PDF
    AbstractIntroductionAdoption of endovascular aneurysm repair (EVAR) has led to significant reductions in the short-term morbidity and mortality associated with abdominal aortic aneurysm (AAA) repair. However, EVAR may expose both patient and interventionalist to potentially harmful levels of radiation, particularly as more complex procedures are undertaken. The aim of this study was to assess whether changing from radiographer-controlled imaging to a system of operator-controlled imaging (OCI) would influence radiation exposure, screening time or contrast dose during EVAR.MethodRetrospective analysis identified patients that had undergone elective EVAR for infra-renal AAA before or after the change to operator-controlled imaging. Data were collected for radiation dose (measured as dose area product; DAP), screening time, total delivered contrast volume and operative duration. Data were also collected for maximum aneurysm diameter, patient age, gender and body mass index.Results122 patients underwent EVAR for infra-renal AAA at a single centre between January 2011 and December 2011. 57 of these were prior to installation of OCI and 65 after installation. Median DAP was significantly lower after installation of OCI (4.9 mGy m2; range 1.25–13.3) than it had been before installation (6.9 mGy m2; range 1.91–95.0) (p = 0.005). Median screening times before and after installation of OCI were 20.0 min and 16.2 min respectively (p = 0.027) and median contrast volumes before and after the change to OCI were 100 ml and 90 ml respectively (p = 0.21).ConclusionIntroduction of operator-controlled imaging can significantly reduce radiation exposure during EVAR, with particular reduction in the number of ‘higher-dose’ cases
    corecore