    In-process phase growth measurement technique in the fabrication of monolithic porous layer open tubular (monoPLOT) columns using capacitively coupled contactless conductivity

    Get PDF
    A technique for the in-process measurement of polymer stationary phase growth inside fused silica capillaries during the fabrication of monolithic porous layer open tubular (monoPLOT) columns is presented. In this work, capacitively coupled contactless conductivity detection (C4D) was applied as an online measurement tool for porous polymer layer growth within fused silica capillaries. The relationship between effective capillary diameter and C4D response was investigated for two polymers, butyl methacrylate–ethylene dimethacrylate (BuMA–EDMA) and polystyrene–divinylbenzene (PS–DVB) over a range of capillary diameters and layer thicknesses. The described technique can be used with both thermal and photo-initiated approaches for monoPLOT fabrication and provides an accurate, realtime measurement of the porous layer growth within the capillary, which should vastly improve columnto-column reproducibility. The technique was shown to be very precise, with a measured %RSD < 10%

    Focussed ion beam serial sectioning and imaging of monolithic materials for 3D reconstruction and morphological parameter evaluation

    Get PDF
    A new characterisation method, based on the utilisation of focussed ion beam-scanning electron microscopy (FIB-SEM), has been employed for the evaluation of morphological parameters in porous monolithic materials. Sample FIB serial sectioning, SEM imaging and image processing techniques were used to extract the pore boundaries and reconstruct the 3D porous structure of carbon and silica-based monoliths. Since silica is a non-conducting material, a commercial silica monolith modified with activated carbon was employed instead to minimise the charge build-up during FIB sectioning. This work therefore presents a novel methodology that can be successfully employed for 3D reconstruction of porous monolithic materials which are or can be made conductive through surface or bulk modification. Furthermore, the 3D reconstructions were used for calculation of the monolith macroporosity, which was in good agreement with the porosity values obtained by mercury intrusion porosimetry (MIP)

    Fabrication and characterization of nanotemplated carbon monolithic material

    Get PDF
    A novel hierarchical nanotemplated carbon monolithic rod (NTCM) was prepared using a novel facile nanotemplating approach. The NTCM was obtained using C60-fullerene modified silica gels as hard templates, which were embedded in a phenolic resin containing a metal catalyst for localized graphitization, followed by bulk carbonization, and template and catalyst removal. TEM, SEM, and BET measurements revealed that NTCM possessed an integrated open hierarchical porous structure, with a trimodal pore distribution. This porous material also possessed a high mesopore volume and narrow mesopore size distribution. During the course of carbonization, the C60 conjugated to aminated silica was partly decomposed, leading to the formation of micropores. The Raman signature of NTCM was very similar to that of multiwalled carbon nanotubes as exemplified by three major peaks as commonly observed for other carbon materials, i.e., the sp3 and sp2 carbon phases coexisted in the sample. Surface area measurements were obtained using both nitrogen adsorption/desorption isotherms (BET) and with a methylene blue binding assay, with BET results showing the NTCM material possessed an average specific surface area of 435 m2 g−1, compared to an area of 372 m2 g−1 obtained using the methylene blue assay. Electrochemical studies using NTCM modified glassy carbon or boron doped diamond (BDD) electrodes displayed quasi-reversible oxidation/reduction with ferricyanide. In addition, the BDD electrode modified with NTCM was able to detect hydrogen peroxide with a detection limit of below 300 nM, whereas the pristine BDD electrode was not responsive to this target compound

    Adsorption and desorption of methylene blue on porous carbon monoliths and nanocrystalline cellulose

    Get PDF
    The dynamic batch adsorption of methylene blue (MB), a widely used and toxic dye, onto nanocrystalline cellulose (NCC) and crushed powder of carbon monolith (CM) was investigated using the pseudo-first- and -second-order kinetics. CM outperformed NCC with a maximum capacity of 127 mg/g compared to 101 mg/g for NCC. The Langmuir isotherm model was applicable for describing the binding data for MB on CM and NCC, indicating the homogeneous surface of these two materials. The Gibbs free energy of −15.22 kJ/mol estimated for CM unravelled the spontaneous nature of this adsorbent for MB, appreciably faster than the use of NCC (−4.47 kJ/mol). Both pH and temperature exhibited only a modest effect on the adsorption of MB onto CM. The desorption of MB from CM using acetonitrile was very effective with more than 94 % of MB desorbed from CM within 10 min to allow the reusability of this porous carbon material. In contrast, acetonitrile was less effective than ethanol in desorbing MB from NCC. The two solvents were incapable of completely desorbing MB on commercial granular coal-derived activated carbon

    Paired emitter-detector diode detection with dual wavelength monitoring for enhanced sensitivity to transition metals in ion chromatography with post-column reaction

    Get PDF
    The combination of post-column derivatisation and visible detection are regularly employed in ion chromatography (IC) to detect poorly absorbing species. Although this mode is often highly sensitive, one disadvantage is the increase in repeating baseline artifacts associated with out-of-sync pumping systems. The work presented here will demonstrate the use of a second generation design paired emitter-detector diode (PEDD-II) detection mode offering enhanced sensitivity to transition metals in IC by markedly reducing this problem and also by improving signal noise. First generation designs demonstrated the use of a single integrated PEDD detector cell as a simple, small (15 x 5 mm), highly sensitive, low cost photometric detector for the detection of metals in ion chromatography (IC). The basic principle of this detection mode lies in the employment of two linear light emitting diodes (LEDs), one operating in normal mode as a light source and the other in reverse bias serving as a light detector. The second generation PEDD-II design showed increased sensitivity for Mn(II)- and Co(II)-2-(pyridylazo) resorcinol (PAR) complexes as a result of two simultaneously acquiring detection cells - one analytical PEDD cell and one reference PEDD cell. Therefore, the PEDD-II employs two wavelengths whereby one monitors the analyte reaction product and the second monitors a wavelength close to the isosbestic point. The optimum LED wavelength to be used for the analytical cell was investigated to maximise peak response. The fabrication process for both the analytical and reference PEDD cells was validated by determining the reproducibility of detectors within a batch. The reproducibility and sensitivity of the PEDD-II detector was then investigated using signals obtained from both intra- and inter-day chromatograms

    Novel integrated paired emitter-detector diode (PEDD) as a miniaturized photometric detector in HPLC

    Get PDF
    A novel low power, low cost, highly sensitive, miniaturized light emitting diode (LED) based flow detector has been used as optical detector for the detection of sample components in high performance liquid chromatography (HPLC). This colorimetric detector employs two LEDs, one operating in normal mode as a light source and the other is reverse biased to work as a light detector. Instead of measuring the photocurrent directly, a simple timer circuit is used to measure the time taken for the photocurrent generated by the emitter LED (λmax 500 nm) to discharge the detector LED (λmax 621 nm) from 5 V (logic 1) to 1.7 V (logic 0) to give digital output directly without using an A/D converter. Employing a post-column reagent method, a Nucleosil 100-7 (functionalised with iminodiacetic acid (IDA) groups) column was used to separate a mixture of transition metal complexes, manganese (II) and cobalt (II) in PAR. All optical measurements were taken by using both the in built HPLC variable wavelength detector and the proposed paired-emitter-detector-diode (PEDD) optical detector configured in-line for data comparison. The concentration range investigated using the PEDD was found to give a linear response to the Mn (II) and Co (II) PAR complexes. The effects of flow rate and emitter LED light source intensity were investigated. Under optimised conditions the PEDD detector offered a linear range of 0.9-100 µM and LOD of 0.09 µM for Mn-PAR complex. A linear range of 0.2-100 µM and LOD of 0.09 µM for Co-PAR complex was achieved

    Mathematical model of a fluxgate magnetometer

    Get PDF
    In paper analytical equations for calculate the electromotive force in the measuring coil of the fluxgate magnetometer independent of the drive signal frequency content are presented. Also, the equations for es-timation of the fluxgate sensitivity at any harmonic and for study fluxgates operation with a glance to the waveform and the polynomial approximation of the mean magnetization curve of the core are provided