7 research outputs found

    HBM4EU chromates study - Overall results and recommendations for the biomonitoring of occupational exposure to hexavalent chromium

    Get PDF
    Exposure to hexavalent chromium [Cr(VI)] may occur in several occupational activities, e.g., welding, Cr(VI) electroplating and other surface treatment processes. The aim of this study was to provide EU relevant data on occupational Cr(VI) exposure to support the regulatory risk assessment and decision-making. In addition, the capability and validity of different biomarkers for the assessment of Cr(VI) exposure were evaluated. The study involved nine European countries and involved 399 workers in different industry sectors with exposures to Cr(VI) such as welding, bath plating, applying or removing paint and other tasks. We also studied 203 controls to establish a background in workers with no direct exposure to Cr(VI). We applied a cross-sectional study design and used chromium in urine as the primary biomonitoring method for Cr(VI) exposure. Additionally, we studied the use of red blood cells (RBC) and exhaled breath condensate (EBC) for biomonitoring of exposure to Cr(VI). Personal measurements were used to study exposure to inhalable and respirable Cr(VI) by personal air sampling. Dermal exposure was studied by taking hand wipe samples. The highest internal exposures were observed in the use of Cr(VI) in electrolytic bath plating. In stainless steel welding the internal Cr exposure was clearly lower when compared to plating activities. We observed a high correlation between chromium urinary levels and air Cr(VI) or dermal total Cr exposure. Urinary chromium showed its value as a first approach for the assessment of total, internal exposure. Correlations between urinary chromium and Cr(VI) in EBC and Cr in RBC were low, probably due to differences in kinetics and indicating that these biomonitoring approaches may not be interchangeable but rather complementary. This study showed that occupational biomonitoring studies can be conducted successfully by multi-national collaboration and provide relevant information to support policy actions aiming to reduce occupational exposure to chemicals.This work has received funding from the European Union's Horizon 2020 research and innovation program under grant agreement No 733032 and received co-funding from the author's organizations and/or Ministries. Luxembourg entered the study at a later stage and thus financed the study at its own means.S

    Aggregate dermal exposure to cyclic siloxanes in personal care products:implications for risk assessment

    No full text
    Consumers who use personal care products (PCPs) are internally exposed to some of the organic components present of which some may be detected in exhaled air when eliminated. The aim of this study was the quantitative determination of octamethylcyclotetrasiloxane (D4) and decamethylcyclopentasiloxane (D5) in end-exhaled air to study dermal absorption of substances in PCPs. We exposed the forearm of fifteen healthy volunteers for 60 min to pure D4 or D5 and to commercial products containing D4 and D5. Inhalation uptake was kept to a minimum by keeping the forearm in a flow cabinet during dermal exposure and supplying filtered air to the breathing zone of the volunteer during the post-exposure period. End-exhaled air was collected using a breath sampler (Bio-VOC), transferred to carbograph multi-bed adsorbent tubes and analyzed by thermal desorption gas chromatography mass spectrometry (TD-GC-MS). In the end-exhaled air of non-exposed volunteers background concentrations of D4 (0.8–3.5 ng/L) and D5 (0.8–4.0 ng/L) were observed. After exposing the volunteers, the level of D4 and D5 in end-exhaled air did not or barely exceed background concentrations. At t = 90 min, a sharp increase of the D4/D5 concentration in end-exhaled air was observed, which we attributed to the inhalation of the substances during a toilet visit without using inhalation protection devices. When this visit was taken out of the protocol, the sharp increase disappeared. Overall, the results of our study indicate that dermal absorption of D4 and D5 contributes only marginally to internal exposure following dermal applications. As in our study inhalation is the primary route of entry for these compounds, we conclude that its risk assessment should focus on this particular exposure route

    Changes in Work Practices for Safe Use of Formaldehyde in a University-Based Anatomy Teaching and Research Facility

    Get PDF
    Anatomy teaching and research relies on the use of formaldehyde (FA) as a preservation agent for human and animal tissues. Due to the recent classification of FA as a carcinogen, university hospitals are facing a challenge to (further) reduce exposure to FA. The aim of this study was to reduce exposure to FA in the anatomy teaching and research facility. Workers participated in the development of improved work practices, both technical and organizational solutions. Over a period of 6 years mitigating measures were introduced, including improvement of a down-flow ventilation system, introduction of local exhaust ventilation, collection of drain liquid from displayed specimens in closed containers and leak prevention. Furthermore, some organizational changes were made to reduce the number of FA peak exposures. Stationary and personal air sampling was performed in three different campaigns to assess the effect of these new work practices on inhalation exposure to FA. Samples were collected over 8 h (full shift) and 15 min (task-based) to support mitigation of exposure and improvement of work practices. Air was collected on an adsorbent coated with 2,4-dinitrophenylhydrazine (DNPH) and analyzed by HPLC-UV. Geometric mean (GM) concentrations of FA in the breathing zone over a work-shift were 123 µg/m³ in 2012 and 114 µg/m³ in 2014, exceeding the workplace standard of 150 µg/m³ (8 h time-weighted average, TWA) on 46% of the workdays in 2012 and 38% of the workdays in 2014. This exposure was reduced to an average of 28.8 µg/m³ in 2017 with an estimated probability of exceeding the OEL of 0.6%. Task-based measurements resulted in a mean peak exposures of 291 µg/m³ in 2012 (n = 19) and a mean of 272 µg/m³ in 2014 (n = 21), occasionally exceeding the standard of 500 µg/m³ (15 min TWA), and were reduced to a mean of 88.7 µg/m³ in 2017 (n = 12) with an estimated probability of exceeding the OEL of 1.6%

    HBM4EU chromates study - the measurement of hexavalent and trivalent chromium in exhaled breath condensate samples from occupationally exposed workers across Europe

    No full text
    The aim of this study was to investigate the practicability of exhaled breath condensate (EBC) as a biological matrix to detect and measure hexavalent chromium (Cr(VI)) and trivalent chromium (Cr(III)) in workers occupationally exposed to Cr(VI). EBC samples were collected from workers in France, Finland, Italy, The Netherlands and the United Kingdom from three different target activities: chrome platers, stainless steel welders and surface treatment workers. Pre and post working week EBC samples were collected from 177 exposed workers and 98 unexposed workers (control group). Hyphenated chromatography systems with inductively coupled plasma - mass spectrometry (ICP-MS) were for the analysis. The results showed that the occupationally exposed workers had significantly higher levels of Cr(VI) and Cr(III) than the control group. Chrome platers exhibited the highest Cr(VI) levels in their EBC samples, with a significant increase from their pre to post samples for both Cr(VI) and Cr(III). A significant difference was also found between pre and post EBC samples for Cr(III) in welders. This study has shown that EBC has the potential to be a valid, non-invasive biological matrix to assess occupational exposure to Cr(VI) and Cr(III) for biological monitoring assessment, with the ability to detect low level inhalation exposures

    HBM4EU chromates study - Usefulness of measurement of blood chromium levels in the assessment of occupational Cr(VI) exposure

    No full text
    Occupational exposures to hexavalent Chromium (Cr(VI)) can occur in welding, hot working stainless steel processing, chrome plating, spray painting and coating activities. Recently, within the human biomonitoring for Europe initiative (HBM4EU), a study was performed to assess the suitability of different biomarkers to assess the exposure to Cr(VI) in various job tasks. Blood-based biomarkers may prove useful when more specific infor-mation on systemic and intracellular bioavailability is necessary. To this aim, concentrations of Cr in red blood cells (RBC-Cr) and in plasma (P-Cr) were analyzed in 345 Cr(VI) exposed workers and 175 controls to understand how these biomarkers may be affected by variable levels of exposure and job procedures.Compared to controls, significantly higher RBC-Cr levels were observed in bath plating and paint application workers, but not in welders, while all the 3 groups had significantly greater P-Cr concentrations. RBC-Cr and P-Cr in chrome platers showed a high correlation with Cr(VI) in inhalable dust, outside respiratory protective equipment (RPE), while such correlation could not be determined in welders. In platers, the use of RPE had a significant impact on the relationship between blood biomarkers and Cr(VI) in inhalable and respirable dust. Low correlations between P-Cr and RBC-Cr may reflect a difference in kinetics.This study showed that Cr-blood-based biomarkers can provide information on how workplace exposure translates into systemic availability of Cr(III) (extracellular, P-Cr) and Cr(VI) (intracellular, RBC-Cr). Further studies are needed to fully appreciate their use in an occupational health and safety context
    corecore