45 research outputs found

    Czasem trzeba owijać w bawełnę. Eufemizmy w materiałach dydaktycznych dla cudzoziemców

    Get PDF
    Zadanie pt. Digitalizacja i udostępnienie w Cyfrowym Repozytorium Uniwersytetu Łódzkiego kolekcji czasopism naukowych wydawanych przez Uniwersytet Łódzki nr 885/P-DUN/2014 zostało dofinansowane ze środków MNiSW w ramach działalności upowszechniającej naukę

    Multifunctional Ligand Approach : search for Effective Therapy Against Alzheimers Disease

    Get PDF
    Alzheimer’s disease is a progressive, incurable, and complex neurodegenerative disease. Currently, an effective treatment that can slow down or stop the damage and death of neurons, which is a characteristic of Alzheimer’s disease, is lacking. Taking into account the complex nature of the disease, a multitarget design approach has been developed for the production of new potential anti-AD agents. The goal of this approach is to create a single molecule that can interact selectively with several desired molecular targets relevant to the disease. This strategy was successfully developed two decades ago and has been improved in recent years. This chapter describes the progress made in the discovery and design of selected multitargeted drugs based on molecular targets, which can be used for treating Alzheimer’s disease. The most promising among these drugs are the molecules having properties that are valuable not only in the symptomatic therapy but also in the causal treatment of the disease. The main hypotheses of Alzheimer’s disease, such as β-amyloid (Aβ), tau, and cholinergic, suggest that compounds capable of inhibiting the aggregation of neurotoxic Aβ amyloid peptide and tau protein, and improving the cholinergic neurotransmission, may possess such properties. Examples of such multifunctional molecules, which have been recently reported in the literature, are presented in this chapter

    Moral and Ethic Values in Employment as a Factor of Innovative Component of Employment Potential in Ukraine

    Get PDF
    Purpose - to show the role of moral and ethic values in the conditions of knowledge economy development and increased competition towards innovative development to employment potential in Ukraine; to determine the main problems and reasons of employees' value demoralization; to propose measures for their improvement

    Co warto wiedzieć. Poradnik metodyczny dla nauczycieli języka polskiego jako obcego na Wschodzie

    Get PDF
    Poradnik jest rezultatem bogatej wiedzy i wieloletniego doświadczenia Autorek w nauczaniu języka polskiego jako obcego. Autorki poruszają między innymi zagadnienia związane z programami nauczania, podręcznikami i pomocami dydaktycznymi w nauczaniu języka polskiego jako obcego, sposobami nauczania, nauczaniem sprawności językowych, planowaniem lekcji, nauczaniem wiedzy o Polsce. Publikacja powstała głównie z myślą o nauczycielach kierowanych z Polski do pracy wśród Polonii i Polaków zamieszkałych za granicą w celu nauczania języka polskiego, historii i geografii Polski, krzewienia polskiej kultury i tradycji. Mamy jednak nadzieję, że publikacja ta będzie inspiracją i pomocą nie tylko dla nauczycieli rozpoczynających pracę za granicą, ale i dla nauczycieli w kraju uczących języka polskiego jako obcego w środowiskach rosyjskojęzycznych, a także studentów specjalności „nauczanie języka polskiego jako obcego” oraz słuchaczy analogicznych studiów podyplomowych

    The influence of patients preparation on the diagnostic value of radiographs episode back-cross the spine

    Get PDF
    Diagnostyka radiologiczna jest współcześnie kluczowym narzędziem w rozpoznawaniu wielu chorób i ma ważną rolę w kontroli leczenia. Zdjęcie rentgenowskie jest łatwo dostępnym, szybkim i tanim sposobem oceny kręgosłupa w odcinku lędźwiowo-krzyżowym (LS). Uzyskanie prawidłowego i dokładnego obrazu kręgosłupa lędźwiowego, a także innych struktur anatomicznych znajdujących się w tej okolicy, należy poprzedzić usunięciem z dolnego odcinka przewodu pokarmowego gazów jelitowych oraz mas kałowych. Przygotowanie pacjenta do wykonania zdjęcia RTG kręgosłupa w odcinku LS wymaga wprowadzenia kontrolowanej diety wykluczającej oraz łagodnych środków przeczyszczających i/lub redukujących wzdęcia w celu oczyszczenia przewodu pokarmowego z mas kałowych i gazów jelitowych.The radio graphics have been still crucial diagnosis tools to detect many diseases and have important role in the treatments control. The X-ray picture is available, quick and cheap diagnostics method to evaluation the lumbar-sacral spine (LS) abnormalities. To obtain the right and exact lumbar-sacral spine and other surrounded anatomical structures images, the preceded by the removal from the lower section of the gastrointestinal intestinal gases and faecal masses should be done. The special patients preparation before X-ray exam of LS requisites the introduction of controlled diet excludes and mild laxatives and/or reduce bloating pills in order to cleanse the digestive tract of the faecal masses and intestinal gases

    Synthesis, molecular modelling and biological evaluation of novel heterodimeric, multiple ligands targeting cholinesterases and amyloid beta

    Get PDF
    Cholinesterases and amyloid beta are one of the major biological targets in the search for a new and efficacious treatment of Alzheimer’s disease. The study describes synthesis and pharmacological evaluation of new compounds designed as dual binding site acetylcholinesterase inhibitors. Among the synthesized compounds, two deserve special attention—compounds 42 and 13. The former is a saccharin derivative and the most potent and selective acetylcholinesterase inhibitor (EeAChE IC50 = 70 nM). Isoindoline-1,3-dione derivative 13 displays balanced inhibitory potency against acetyl- and butyrylcholinesterase (BuChE) (EeAChE IC50 = 0.76 μM, EqBuChE IC50 = 0.618 μM), and it inhibits amyloid beta aggregation (35.8% at 10 μM). Kinetic studies show that the developed compounds act as mixed or non-competitive acetylcholinesterase inhibitors. According to molecular modelling studies, they are able to interact with both catalytic and peripheral active sites of the acetylcholinesterase. Their ability to cross the blood-brain barrier (BBB) was confirmed in vitro in the parallel artificial membrane permeability BBB assay. These compounds can be used as a solid starting point for further development of novel multifunctional ligands as potential anti-Alzheimer’s agents

    Initial Polish experience of Flexible 19 gauge Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

    Get PDF
      INTRODUCTION: EBUS is a well established minimally invasive diagnostic tool for mediastinal and hilar lymphadenopathy. The novel ViziShot Flex 19G needle (Olympus Respiratory America, Redmond, WA, USA) was introduced in 2015 in order to improve loaded scope flexion and to obtain larger tissue samples for analysis. The aims of this study were to assess diagnostic yield of Flex 19G needles and to present endoscopist’s feedback about the endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). MATERIAL AND METHODS: The Flex 19G needles were used in patients with hilar and/or mediastinal adenopathy in two Polish pulmonology centers. Cytology smears and cell blocks (CB) were prepared. The prospective analysis was performed due to collected data. RESULTS: Twenty two selected patients with confirmed adenopathy on chest-CT (mean age 58 ± 12) underwent EBUS-TBNA with use of Flex 19G needles. All procedures occurred to be diagnostic for smears (yield 100%). The malignancy was found in 15 cases (68.2%), and benign adenopathy in 7 (31.8%). In 12 of 14 cases of lung cancer (yield 85.7%) CB were diagnostic for immunohistochemical and molecular staining. After puncturing nodes, especially in hilar position not extensive bleeding was observed. Comparing to standard 21/22G EBUS-TBNA endoscopists underlined better flexion of loaded scope and sample adequacy and found non-significant differences in another biopsy details. CONCLUSIONS: The first Polish experience with use of Flex 19G EBUS-TBNA needle occurs to be similar in performance with standard technique with use of 22/21G needles and presents high diagnostic yield for lung cancer diagnostics, especially when preparing CB. A safety profile of the biopsy is acceptable.

    Initial Polish experience of flexible 19 gauge endobronchial ultrasound-guided transbronchial needle aspiration

    Get PDF
    Introduction: EBUS is a well established minimally invasive diagnostic tool for mediastinal and hilar lymphadenopathy. The novel ViziShot Flex 19G needle (Olympus Respiratory America, Redmond, WA, USA) was introduced in 2015 in order to improve loaded scope flexion and to obtain larger tissue samples for analysis. The aims of this study were to assess diagnostic yield of Flex 19G needles and to present endoscopist’s feedback about the endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). Material and methods: The Flex 19G needles were used in patients with hilar and/or mediastinal adenopathy in two Polish pulmonology centers. Cytology smears and cell blocks (CB) were prepared. The prospective analysis was performed due to collected data. Results: Twenty two selected patients with confirmed adenopathy on chest-CT (mean age 58 ± 12) underwent EBUS-TBNA with use of Flex 19G needles. All procedures occurred to be diagnostic for smears (yield 100%). The malignancy was found in 15 cases (68.2%), and benign adenopathy in 7 (31.8%). In 12 of 14 cases of lung cancer (yield 85.7%) CB were diagnostic for immunohistochemical and molecular staining. After puncturing nodes, especially in hilar position not extensive bleeding was observed. Comparing to standard 21/22G EBUS-TBNA endoscopists underlined better flexion of loaded scope and sample adequacy and found non-significant differences in another biopsy details. Conclusions: The first Polish experience with use of Flex 19G EBUS-TBNA needle occurs to be similar in performance with standard technique with use of 22/21G needles and presents high diagnostic yield for lung cancer diagnostics, especially when preparing CB. A safety profile of the biopsy is acceptable

    Wstępne polskie doświadczenia z użyciem igły Flex 19G do przezoskrzelowej biopsji pod kontrolą ultrasonografii wewnątrzoskrzelowej

    Get PDF
    WSTĘP: EBUS (endobronchial ultrasonography) jest małoinwazyjną metodą diagnostyczną o dobrze ugruntowanej pozycji w diagnostyce limfadenopatii śródpiersia i wnęk płucnych. ViziShotFlex 19G needle to nowa igła przeznaczona do zastosowania w tym badaniu wprowadzona na rynek przez firmę Olympus w 2015 roku. Jej konstrukcja ma zapewnić większą giętkość uzbrojonego endoskopu oraz uzyskanie większej ilości materiału tkankowego do analizy. Cele niniejszej pracy to ocena wydolności diagnostycznej procedury EBUS-TBNA (EBUS — transbronchial needle aspiration) z zastosowaniem igły Flex 19G oraz prezentacja opinii endoskopistów na temat badania z jej użyciem. MATERIAŁ I METODY: Igły Flex 19G zastosowano w diagnostyce pacjentów z adenopatią śródpiersia i/lub wnęk w dwóch ośrodkach pulmonologicznych w Polsce. Wykonywano zarówno rozmazy cytologiczne, jak i bloki komórkowe (CB — cell blocks). Dokonano prospektywnej analizy zebranych danych. WYNIKI: Dwudziestu dwóch wybranych pacjentów z adenopatią potwierdzoną w tomografii komputerowej (średnia wieku 58 ± 12 lat) podano badaniu EBUS-TBNA z użyciem igieł Flex 19G. Wszystkie wykonane rozmazy cytologiczne okazały się diagnostyczne (wydolność diagnostyczna 100%). Złośliwy charakter zmiany stwierdzono w 15 przypadkach (68,2%), natomiast łagodną adenopatię u 7 pacjentów (31,8%). W 12 z 14 przypadków raka płuca wykonane CB mogły być użyte do oznaczeń immunohistochemicznych i molekularnych. Po biopsji węzłów chłonnych, zwłaszcza wnękowych, nie obserwowano nasilonego krwawienia. W porównaniu ze standardową procedurą EBUS-TBNA z użyciem igły 21/22G endoskopiści podkreślali większą giętkość uzbrojonego endoskopu oraz jakość bioptatu, natomiast w pozostałych aspektach biopsji różnice były nieznaczące. WNIOSKI: Pierwsze polskie doświadczenia z użyciem igieł Flex 19G okazują się być podobne do standardowej techniki z użyciem igieł 21/22G oraz prezentują wysoką wydolność diagnostyczną w raku płuca, szczególnie z zastosowaniem CB. Profil bezpieczeństwa biopsji jest akceptowalny.WSTĘP: EBUS (endobronchial ultrasonography) jest małoinwazyjną metodą diagnostyczną o dobrze ugruntowanej pozycji w diagnostyce limfadenopatii śródpiersia i wnęk płucnych. ViziShotFlex 19G needle to nowa igła przeznaczona do zastosowania w tym badaniu wprowadzona na rynek przez firmę Olympus w 2015 roku. Jej konstrukcja ma zapewnić większą giętkość uzbrojonego endoskopu oraz uzyskanie większej ilości materiału tkankowego do analizy. Cele niniejszej pracy to ocena wydolności diagnostycznej procedury EBUS-TBNA (EBUS — transbronchial needle aspiration) z zastosowaniem igły Flex 19G oraz prezentacja opinii endoskopistów na temat badania z jej użyciem. MATERIAŁ I METODY: Igły Flex 19G zastosowano w diagnostyce pacjentów z adenopatią śródpiersia i/lub wnęk w dwóch ośrodkach pulmonologicznych w Polsce. Wykonywano zarówno rozmazy cytologiczne, jak i bloki komórkowe (CB — cell blocks). Dokonano prospektywnej analizy zebranych danych. WYNIKI: Dwudziestu dwóch wybranych pacjentów z adenopatią potwierdzoną w tomografii komputerowej (średnia wieku 58 ± 12 lat) podano badaniu EBUS-TBNA z użyciem igieł Flex 19G. Wszystkie wykonane rozmazy cytologiczne okazały się diagnostyczne (wydolność diagnostyczna 100%). Złośliwy charakter zmiany stwierdzono w 15 przypadkach (68,2%), natomiast łagodną adenopatię u 7 pacjentów (31,8%). W 12 z 14 przypadków raka płuca wykonane CB mogły być użyte do oznaczeń immunohistochemicznych i molekularnych. Po biopsji węzłów chłonnych, zwłaszcza wnękowych, nie obserwowano nasilonego krwawienia. W porównaniu ze standardową procedurą EBUS-TBNA z użyciem igły 21/22G endoskopiści podkreślali większą giętkość uzbrojonego endoskopu oraz jakość bioptatu, natomiast w pozostałych aspektach biopsji różnice były nieznaczące. WNIOSKI: Pierwsze polskie doświadczenia z użyciem igieł Flex 19G okazują się być podobne do standardowej techniki z użyciem igieł 21/22G oraz prezentują wysoką wydolność diagnostyczną w raku płuca, szczególnie z zastosowaniem CB. Profil bezpieczeństwa biopsji jest akceptowalny
    corecore