1,030 research outputs found

    Social Determinants of Community Health Services Utilization among the Users in China: A 4-Year Cross-Sectional Study

    Get PDF
    Background To identify social factors determining the frequency of community health service (CHS) utilization among CHS users in China. Methods Nationwide cross-sectional surveys were conducted in 2008, 2009, 2010, and 2011. A total of 86,116 CHS visitors selected from 35 cities were interviewed. Descriptive analysis and multinomial logistic regression analysis were employed to analyze characteristics of CHS users, frequency of CHS utilization, and the socio-demographic and socio-economic factors influencing frequency of CHS utilization. Results Female and senior CHS clients were more likely to make 3–5 and ≥6 CHS visits (as opposed to 1–2 visits) than male and young clients, respectively. CHS clients with higher education were less frequent users than individuals with primary education or less in 2008 and 2009; in later surveys, CHS clients with higher education were the more frequent users. The association between frequent CHS visits and family income has changed significantly between 2008 and 2011. In 2011, income status did not have a discernible effect on the likelihood of making ≥6 CHS visits, and it only had a slight effect on making 3–5 CHS visits. Conclusion CHS may play an important role in providing primary health care to meet the demands of vulnerable populations in China. Over time, individuals with higher education are increasingly likely to make frequent CHS visits than individuals with primary school education or below. The gap in frequency of CHS utilization among different economic income groups decreased from 2008 to 2011

    Metabolism during anaesthesia and recovery in colic and healthy horses: a microdialysis study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Muscle metabolism in horses has been studied mainly by analysis of substances in blood or plasma and muscle biopsy specimens. By using microdialysis, real-time monitoring of the metabolic events in local tissue with a minimum of trauma is possible. There is limited information about muscle metabolism in the early recovery period after anaesthesia in horses and especially in the colic horse. The aims were to evaluate the microdialysis technique as a complement to plasma analysis and to study the concentration changes in lactate, pyruvate, glucose, glycerol, and urea during anaesthesia and in the recovery period in colic horses undergoing abdominal surgery and in healthy horses not subjected to surgery.</p> <p>Methods</p> <p>Ten healthy university-owned horses given anaesthesia alone and ten client-owned colic horses subjected to emergency abdominal surgery were anaesthetised for a mean (range) of 230 min (193–273) and 208 min (145–300) respectively. Venous blood samples were taken before anaesthesia. Venous blood sampling and microdialysis in the gluteal muscle were performed during anaesthesia and until 24 h after anaesthesia. Temporal changes and differences between groups were analysed with an ANOVA for repeated measures followed by Tukey Post Hoc test or Planned Comparisons.</p> <p>Results</p> <p>Lactate, glucose and urea, in both dialysate and plasma, were higher in the colic horses than in the healthy horses for several hours after recovery to standing. In the colic horses, lactate, glucose, and urea in dialysate, and lactate in plasma increased during the attempts to stand. The lactate-to-pyruvate ratio was initially high in sampled colic horses but decreased over time. In the colic horses, dialysate glycerol concentrations varied considerably whereas in the healthy horses, dialysate glycerol was elevated during anaesthesia but decreased after standing. In both groups, lactate concentration was higher in dialysate than in plasma. The correspondence between dialysate and plasma concentrations of glucose, urea and glycerol varied.</p> <p>Conclusion</p> <p>Microdialysis proved to be suitable in the clinical setting for monitoring of the metabolic events during anaesthesia and recovery. It was possible with this technique to show greater muscle metabolic alterations in the colic horses compared to the healthy horses in response to regaining the standing position.</p

    A Target-Based High Throughput Screen Yields Trypanosoma brucei Hexokinase Small Molecule Inhibitors with Antiparasitic Activity

    Get PDF
    African sleeping sickness is a disease found in sub-Saharan Africa that is caused by the single-celled parasite Trypanosoma brucei. The drugs used widely now to treat infections are 50 years old and notable for their toxicity, emphasizing the need for development of new therapeutics. In the search for potential drug targets, researchers typically focus on enzymes or proteins that are essential to the survival of the infectious agent while being distinct enough from the host to avoid accidental targeting of the host enzyme. This work describes our research on one such trypanosome enzyme, hexokinase, which is a protein that the parasite requires to make energy. Here we describe the results of our search for inhibitors of the parasite enzyme. By screening 220,223 compounds for anti-hexokinase activity, we have identified new inhibitors of the parasite enzyme. Some of these are toxic to trypanosomes while having no effect on mammalian cells, suggesting that they may hold promise for the development of new anti-parasitic compounds

    A Quantitative, Non-Destructive Methodology for Habitat Characterisation and Benthic Monitoring at Offshore Renewable Energy Developments

    Get PDF
    Following governments' policies to tackle global climate change, the development of offshore renewable energy sites is likely to increase substantially over coming years. All such developments interact with the seabed to some degree and so a key need exists for suitable methodology to monitor the impacts of large-scale Marine Renewable Energy Installations (MREIs). Many of these will be situated on mixed or rocky substrata, where conventional methods to characterise the habitat are unsuitable. Traditional destructive sampling is also inappropriate in conservation terms, particularly as safety zones around (MREIs) could function as Marine Protected Areas, with positive benefits for biodiversity. Here we describe a technique developed to effectively monitor the impact of MREIs and report the results of its field testing, enabling large areas to be surveyed accurately and cost-effectively. The methodology is based on a high-definition video camera, plus LED lights and laser scale markers, mounted on a “flying array” that maintains itself above the seabed grounded by a length of chain, thus causing minimal damage. Samples are taken by slow-speed tows of the gear behind a boat (200 m transects). The HD video and randomly selected frame grabs are analysed to quantify species distribution. The equipment was tested over two years in Lyme Bay, UK (25 m depth), then subsequently successfully deployed in demanding conditions at the deep (>50 m) high-energy Wave Hub site off Cornwall, UK, and a potential tidal stream energy site in Guernsey, Channel Islands (1.5 ms−1 current), the first time remote samples from such a habitat have been achieved. The next stage in the monitoring development process is described, involving the use of Remote Operated Vehicles to survey the seabed post-deployment of MREI devices. The complete methodology provides the first quantitative, relatively non-destructive method for monitoring mixed-substrate benthic communities beneath MPAs and MREIs pre- and post-device deployment

    In vivo biosensing via tissue-localizable near-infrared-fluorescent single-walled carbon nanotubes

    Get PDF
    Single-walled carbon nanotubes are particularly attractive for biomedical applications, because they exhibit a fluorescent signal in a spectral region where there is minimal interference from biological media. Although single-walled carbon nanotubes have been used as highly sensitive detectors for various compounds, their use as in vivo biomarkers requires the simultaneous optimization of various parameters, including biocompatibility, molecular recognition, high fluorescence quantum efficiency and signal transduction. Here we show that a polyethylene glycol ligated copolymer stabilizes near-infrared-fluorescent single-walled carbon nanotubes sensors in solution, enabling intravenous injection into mice and the selective detection of local nitric oxide concentration with a detection limit of 1 µM. The half-life for liver retention is 4 h, with sensors clearing the lungs within 2 h after injection, thus avoiding a dominant route of in vivo nanotoxicology. After localization within the liver, it is possible to follow the transient inflammation using nitric oxide as a marker and signalling molecule. To this end, we also report a spatial-spectral imaging algorithm to deconvolute fluorescence intensity and spatial information from measurements. Finally, we demonstrate that alginate-encapsulated single-walled carbon nanotubes can function as implantable inflammation sensors for nitric oxide detection, with no intrinsic immune reactivity or other adverse response for more than 400 days.National Institutes of Health (U.S.) (T32 Training Grant in Environmental Toxicology ES007020)National Cancer Institute (U.S.) (Grant P01 CA26731)National Institute of Environmental Health Sciences (Grant P30 ES002109)Arnold and Mabel Beckman Foundation (Young Investigator Award)National Science Foundation (U.S.). Presidential Early Career Award for Scientists and EngineersScientific and Technological Research Council of Turkey (TUBITAK 2211 Research Fellowship Programme)Scientific and Technological Research Council of Turkey (TUBITAK 2214 Research Fellowship Programme)Middle East Technical University. Faculty Development ProgrammeSanofi Aventis (Firm) (Biomedical Innovation Grant

    Failure of a repeat course of cyclooxygenase inhibitor to close a PDA is a risk factor for developing chronic lung disease in ELBW infants

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The optimal treatment regimen or protocol for managing a persistent patent ductus arteriosus (PDA) in extremely low birth weight (ELBW) infants has not been well established. This study was aimed at evaluating the failure rate of a cyclooxygenase (COX) inhibitor (COI) for PDA closure and to determine the incidence of a PDA requiring ligation in ELBW infants. We examined the clinical characteristics and risk factors that may predict the clinical consequences of failure of PDA closure by COI.</p> <p>Methods</p> <p>Medical information on 138 infants with birth weight (BW) < 1000 gm who survived for > 48 hours was retrieved. Clinical characteristics and outcomes of patients whose PDAs closed with COI were compared with those who did not close.</p> <p>Results</p> <p>Of the 138 patients, 112 survived to discharge. Eighty (71.4%) of those who survived received 1-3 courses of COI treatment for a symptomatic PDA. A total of 32 (40%) failed COI treatment and underwent PDA ligation. Multivariable logistic regression analysis suggests that the observed differences in the outcomes in infants with or without symptomatic PDA can be explained by the babies with symptomatic PDA being more immature and sicker. No significant difference was seen in the incidence of chronic lung disease (CLD) in infants whose PDA was treated medically versus those who failed medical treatment and then underwent ligation. However, after adjusting for disease severity and other known risk factors, the odds ratio of developing CLD for surviving babies with a persistent PDA compared to those whose PDA was successfully closed with 1-2 courses of COI is 3.24 (1.07-9.81; p = 0.038).</p> <p>Conclusions</p> <p>When successfully treated, PDA in ELBW infants did not contribute significantly to the adverse outcomes such as CLD, retinopathy of prematurity (ROP) and age at discharge. This suggests that it is beneficial for a hemodynamically significant PDA to be closed. The failure of a repeat course of COI to close a PDA is a major risk factor for developing CLD in ELBW infants.</p
    corecore