6,174 research outputs found

    The interpretation of the field angle dependence of the critical current in defect-engineered superconductors

    Full text link
    We apply the vortex path model of critical currents to a comprehensive analysis of contemporary data on defect-engineered superconductors, showing that it provides a consistent and detailed interpretation of the experimental data for a diverse range of materials. We address the question of whether electron mass anisotropy plays a role of any consequence in determining the form of this data and conclude that it does not. By abandoning this false interpretation of the data, we are able to make significant progress in understanding the real origin of the observed behavior. In particular, we are able to explain a number of common features in the data including shoulders at intermediate angles, a uniform response over a wide angular range and the greater discrimination between individual defect populations at higher fields. We also correct several misconceptions including the idea that a peak in the angular dependence of the critical current is a necessary signature of strong correlated pinning, and conversely that the existence of such a peak implies the existence of correlated pinning aligned to the particular direction. The consistency of the vortex path model with the principle of maximum entropy is introduced.Comment: 14 pages, 7 figure

    Noise suppression due to long-range Coulomb interaction: Crossover between diffusive and ballistic transport regimes

    Full text link
    We present a Monte Carlo analysis of shot-noise suppression due to long-range Coulomb interaction in semiconductor samples under a crossover between diffusive and ballistic transport regimes. By varying the mean time between collisions we find that the strong suppression observed under the ballistic regime persists under quasi-ballistic conditions, before being washed out when a complete diffusive regime is reached.Comment: RevTex, 3 pages, 4 figures, minor correction

    Animal board invited review: Opportunities and challenges in using GWP* to report the impact of ruminant livestock on global temperature change

    Get PDF
    Ruminant livestock is a large contributor of CH4 emissions globally. Assessing how this CH4 and other greenhouse gases (GHG) from livestock contribute to anthropogenic climate change is key to understanding their role in achieving any temperature targets. The climate impacts of livestock, as well as other sectors or products/services, are generally expressed as CO2-equivalents using 100-year Global Warming Potentials (GWP100). However, the GWP100 cannot be used to translate emission pathways of short-lived climate pollutants (SLCPs) emissions to their temperature outcomes. A key limitation of handling long- and short-lived gases in the same manner is revealed in the context of any potential temperature stabilisation goals: to achieve this outcome, emissions of long-lived gases must decline to net-zero, but this is not the case for SLCPs. A recent alternative metric, GWP* (so-called ‘GWP-star’), has been proposed to overcome these concerns. GWP* allows for simple appraisals of warming over time for emission series of different GHGs that may not be obvious if using pulse-emission metrics (i.e. GWP100). In this article, we explore some of the strengths and limitations of GWP* for reporting the contribution of ruminant livestock systems to global temperature change. A number of case studies are used to illustrate the potential use of the GWP* metric to, for example, understand the current contribution of different ruminant livestock production systems to global warming, appraise how different production systems or mitigations compare (having a temporal element), and seeing how possible emission pathways driven by changes in production, emissions intensity and gas composition show different impacts over time. We suggest that for some contexts, particularly if trying to directly infer contributions to additional warming, GWP* or similar approaches can provide important insight that would not be gained from conventional GWP100 reporting. © 2023This research is supported by María de Maeztu excellence accreditation 2018-2022 (Ref. MDM-2017-0714), funded by MCIN/AEI/10.13039/501100011033/; and by the Basque Government through the BERC 2022-2025 program. Agustin del Prado is financed by the programme Ramon y Cajal from the Spanish Ministry of Economy, Industry and Competitiveness (RYC-2017-22143) and Ikerbasque. JL acknowledges funding from Wellcome Trust, Our Planet Our Health (Livestock, Environment and People—LEAP), award number 205212/Z/16/Z. FM and SH are funded by the California Air Resources Board (CARB35C10_18ISD025

    Development and operation of a pixel segmented liquid-filled linear array for radiotherapy quality assurance

    Full text link
    A liquid isooctane (C8_{8}H18_{18}) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm ×\times 1.7 mm and a gap of 0.5 mm. The small pixel size makes the detector ideal for high gradient beam profiles like those present in Intensity Modulated Radiation Therapy (IMRT) and radiosurgery. As read-out electronics we use the X-Ray Data Acquisition System (XDAS) with the Xchip developed by the CCLRC. Studies concerning the collection efficiency dependence on the polarization voltage and on the dose rate have been made in order to optimize the device operation. In the first tests we have studied dose rate and energy dependences, and signal reproducibility. Dose rate dependence was found lower than 2.5 % up to 5 Gy min1^{-1}, and energy dependence lower than 2.1 % up to 20 cm depth in solid water. Output factors and penumbras for several rectangular fields have been measured with the linear array and were compared with the results obtained with a 0.125 cm3^{3} air ionization chamber and radiographic film, respectively. Finally, we have acquired profiles for an IMRT field and for a virtual wedge. These profiles have also been compared with radiographic film measurements. All the comparisons show a good correspondence. Signal reproducibility was within a 2% during the test period (around three months). The device has proved its capability to verify on-line therapy beams with good spatial resolution and signal to noise ratio.Comment: 16 pages, 12 figures Submitted to Phys. Med. Bio

    Atherogenic Lipid Profile Of Brazilian Near-term Newborns.

    Get PDF
    Cardiovascular disease is the primary cause of death in Brazil. Recent studies have shown that low birth weight and preterm birth are linked to a higher prevalence of cardiovascular disease. The aim of the present study was to compare the levels of lipids and apolipoproteins and atherogenic indexes between term and near-term newborn infants. A sample of umbilical cord blood was obtained from 135 newborns (66 males) divided into two groups: 25 near-term neonates (35-36.6 weeks of gestational age) and 110 term neonates (37-42 weeks of gestational age). The total cholesterol concentrations were higher in the near-term neonates than in the term group (94.04 +/- 8.02 vs 70.42 +/- 1.63 mg/dl, P < 0.01), due to an increase in the LDL-cholesterol fraction in the near-term group (57.76 +/- 6.39 vs 34.38 +/- 1.29 mg/dl, P < 0.001). The atherogenic indexes (total cholesterol/HDL-cholesterol, LDL-cholesterol/HDL-cholesterol and apolipoprotein B/apolipoprotein A-I) were higher in the near-term group (P < 0.001, P < 0.001, and P < 0.05, respectively). The gestational age of the newborns was inversely correlated with total cholesterol and LDL-cholesterol, and also with the total cholesterol/HDL-cholesterol and LDL-cholesterol/HDL-cholesterol indexes. These findings demonstrate that the lipid profile is worse in the group of near-term neonates compared with the term group. Future studies are needed to determine if this atherogenic profile in near-term neonates can affect body metabolism, increasing the risk for cardiovascular diseases in adult life.38755-6

    Enhanced dimerization of TiOCl under pressure: spin-Peierls - to - Peierls transition

    Full text link
    We report high-pressure x-ray diffraction and magnetization measurements combined with ab-initio calculations to demonstrate that the high-pressure optical and transport transitions recently reported in TiOCl, correspond in fact to an enhanced Ti3+-Ti3+ dimerization existing already at room temperature. Our results confirm the formation of a metal-metal bond between Ti3+ ions along the b-axis of TiOCl, accompanied by a strong reduction of the electronic gap. The evolution of the dimerization with pressure suggests a crossover from the spin-Peierls to a conventional Peierls situation at high pressures.Comment: 9pages, 4 figure

    Study of H2/N2Mixture Plasma Treatment on the AISI 1045

    Get PDF
    In the present work, we analyzed the effect of the plasma treatment of 80% H2/20% N2 mixture plasma over the AISI 1045 steel. To produce the plasma, an AC discharge of 0.1 A at 350 V was produced at a total pressure of 3.0 Torr. The mixture plasma was analyzed using optical emission spectroscopy (OES), in the wavelength range of 200 to 1100 nm. The principal species observed in the plasma were NH, N2, N2+, H2, and Hα. The electron temperature and ion density have been measured using a double Langmuir probe. The samples of steel were treated by plasma at different discharge times, between 3 and 12 h, at the same pressure and AC parameters (0.1 A and 350 V). The treated samples were characterized using X-ray analysis, finding the phases gamma and epsilon of iron nitride. The thickness of the nitrided layers was measured using a scanning electron microscope (SEM). From the images obtained, it is possible to appreciate the interphase between the nitrided layer and the steel matrix. The relationship between the morphology of the surface of nitrided steel and the wetting was analyzed by measuring the contact angle between the surface and a drop of 5 μL of distilled water. The contact angle of the drop increased with the increase of plasma treatment time. The control sample without treatment presented a smaller angle, and after the treatment the surfaces of the steel became hydrophobic. This may be related to the morphology change of the steel surface produced by plasma treatment

    Wear Behavior of a Ni/Co Bilayer Coating by Physical Vapor Deposition on AISI 1045 Steel

    Get PDF
    Coatings by physical vapor deposition (PVD) have become highly relevant due to their wide range of applications and the rapid rate of coating formation. In this work, AISI steel 1045 was coated with two layers, Ni and Co using the PVD technique. Each coating was deposited with a thickness of 1 μm. After applying the coatings, a post-treatment was applied in an AC plasma reactor using a boron nitride blank in an Ar atmosphere at a pressure of 3 Torr, 0.3 A, and 460 V at 4, 8, and 12h. The post-treatment was characterized by optical emission spectroscopy (OES) in a range of 200-1100 nm. The main species observed by OES were Ar+, N2, N2+, and B+. The coatings on 1045 steel and posttreatment were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). Also, were subjected to tribological tests to analyze wear resistance, using the Pin-on-Disk technique. The coatings on steel 1045 present remarkably better wear properties than the uncoated 1045 steel, being the sample post-treated at 4h that showed a lower wear rate

    The CHESS Survey of the L1157-B1 Shock Region: CO Spectral Signatures of Jet-driven Bow Shocks

    Get PDF
    The unprecedented sensitivity of Herschel coupled with the high resolution of the HIFI spectrometer permits studies of the intensity-velocity relationship I(v) in molecular outflows, over a higher excitation range than possible up to now. Over the course of the CHESS Key Program, we have observed toward the bright bow shock region L1157-B1, the CO rotational transitions between J = 5-4 and J = 16-15 with HIFI, and the J = 1-0, 2-1, and 3-2 with the IRAM 30 m and the Caltech Submillimeter Observatory telescopes. We find that all the line profiles I_(CO)(v) are well fit by a linear combination of three exponential laws ∝ exp (– |v/v_0|) with v_0 = 12.5, 4.4, and 2.5 km s^(–1). The first component dominates the CO emission at J ≥ 13, as well as the high-excitation lines of SiO and H_(2)O. The second component dominates for 3 ≤ J up ≤ 10 and the third one for J_up ≤ 2. We show that these exponentials are the signature of quasi-isothermal shocked gas components: the impact of the jet against the L1157-B1 bow shock (T_k ≃ 210 K), the walls of the outflow cavity associated with B1 (T_k ≃ 64 K), and the older cavity L1157-B2 (T_k ≃ 23 K), respectively. Analysis of the CO line flux in the large-velocity gradient approximation further shows that the emission arises from dense gas (n(H_2) ≥ 10^(5)-10^(6) cm^(–3)) close to LTE up to J = 20. We find that the CO J = 2-1 intensity-velocity relation observed in various other molecular outflows is satisfactorily fit by similar exponential laws, which may hold an important clue to their entrainment process

    Influence of nuclear structure on sub-barrier hindrance in Ni+Ni fusion

    Get PDF
    Fusion-evaporation cross sections for 64^{64}Ni+64^{64}Ni have been measured down to the 10 nb level. For fusion between two open-shell nuclei, this is the first observation of a maximum in the SS-factor, which signals a strong sub-barrier hindrance. A comparison with the 58^{58}Ni+58^{58}Ni, 58^{58}Ni+60^{60}Ni, and 58^{58}Ni+64^{64}Ni systems indicates a strong dependence of the energy where the hindrance occurs on the stiffness of the interacting nuclei.Comment: Submitted to Phys. Rev. Lett. 4 pages, 3 figure
    corecore