27 research outputs found

    The alteration of chloride homeostasis/GABAergic signaling in brain disorders: Could oxidative stress play a role?

    Get PDF
    In neuronal precursors and immature neurons, the depolarizing (excitatory) effect of γ-Aminobutyric acid (GABA) signaling is associated with elevated [Cl−]i; as brain cells mature, a developmental switch occurs, leading to the decrease of [Cl−]i and to the hyperpolarizing (inhibi-tory) effect of GABAergic signaling. [Cl−]i is controlled by two chloride co-transporters: NKCC1, which causes Cl− to accumulate into the cells, and KCC2, which extrudes it. The ontogenetic up-regulation of the latter determines the above-outlined switch; however, many other factors contribute to the correct [Cl−]i in mature neurons. The dysregulation of chloride homeostasis is involved in seizure generation and has been associated with schizophrenia, Down’s Syndrome, Autism Spectrum Disorder, and other neurodevelopmental disorders. Recently, much effort has been put into developing new drugs intended to inhibit NKCC1 activity, while no attention has been paid to the origin of [Cl−]i dysregulation. Our study examines the pathophysiology of Cl− homeo-stasis and focuses on the impact of oxidative stress (OS) and inflammation on the activity of Cl− co-transporters, highlighting the relevance of OS in numerous brain abnormalities and diseases. This hypothesis supports the importance of primary prevention during pregnancy. It also inte-grates the therapeutic framework addressed to restore normal GABAergic signaling by counter-acting the alteration in chloride homeostasis in central nervous system (CNS) cells, aiming at lim-iting the use of drugs that potentially pose a health risk

    The use of invisalign® system in the management of the orthodontic treatment before and after Class III surgical approach

    Get PDF
    The approach to skeletal dysmorphisms in the maxillofacial area usually requires an orthodontic treatment by means of fixed appliances, both before and after the surgical phase. Since its introduction, Invisalign system has become a popular treatment choice for the clinicians because of the aesthetics and comfort of the removable clear aligners compared with the traditional appliances. Therefore, the aim of the present report was to illustrate the management of a malocclusion by means of Invisalign system associated with the traditional surgical technique. The present paper shows a case of a 23-year-old male patient characterized by a Class III malocclusion with lateral deviation of the mandible to the left side and cross-bite on teeth 2.2, 2.3, and 2.4. Invisalign system was used during the pre- and postsurgical phases rather than fixed appliances. The posttreatment cephalometric analysis emphasized the stability of the dental and skeletal symmetry corrections, occlusion and functional balance, over a 6-year follow-up. The results achieved at the end of the treatment showed how Invisalign can be effective in the management of the orthodontic phases in orthognathic surgery. The follow-up after 6 years emphasizes the stability of the treatment over time

    Molecular evidence of Listeria monocytogenes infection relapse in a severe case of endocarditis

    Get PDF
    Introduction. Endocarditis is a rare complication of bacteraemia due to Listeria monocytogenes and is characterized by a high fatality rate (37\u201350\u200a%). Recurrent infection by Listeria monocytogenes occurs even more rarely. Case presentation. We report a case of recurrent Listeria monocytogenes infection that resulted in severe endocarditis in a 66-year-old patient with an aortic valve prosthesis. Relapse was confirmed by pulsed-field gel electrophoresis (PFGE) and multi-locus sequence typing (MLST). Conclusion. Our case highlights that the molecular subtyping approach is an important tool for the detection of microbial reinfections and for the support of clinical diagnosis

    Sutureless Perceval Aortic Valve Versus Conventional Stented Bioprostheses: Meta‐Analysis of Postoperative and Midterm Results in Isolated Aortic Valve Replacement

    Get PDF
    Background Aortic stenosis is the most common valvular disease and has a dismal prognosis without surgical treatment. The aim of this meta-analysis was to quantitatively assess the comparative effectiveness of the Perceval (LivaNova) valve versus conventional aortic bioprostheses. Methods and ResultsA total of 6 comparative studies were identified, including 639 and 760 patients who underwent, respectively, aortic valve replacement with the Perceval sutureless valve (P group) and with a conventional bioprosthesis (C group). Aortic cross-clamping and cardiopulmonary bypass duration were significantly lower in the P group. No difference in postoperative mortality was shown for the P and C groups (2.8% versus 2.7%, respectively; odds ratio [OR]: 0.99 [95% confidence interval (CI), 0.52-1.88]; P=0.98). Incidence of postoperative renal failure was lower in the P group compared with the C group (2.7% versus 5.5%; OR: 0.45 [95% CI, 0.25-0.80]; P=0.007). Incidence of stroke (2.3% versus 1.7%; OR: 1.34 [95% CI, 0.56-3.21]; P=0.51) and paravalvular leak (3.1% versus 1.6%; OR: 2.52 [95% CI, 0.60-1.06]; P=0.21) was similar, whereas P group patients received fewer blood transfusions than C group patients (1.161.2 versus 2.13 +/- 2.2; mean difference: 0.99 [95% CI, -1.22 to -0.75]; P=0.001). The incidence of pacemaker implantation was higher in the P than the C group (7.9% versus 3.1%; OR: 2.45 [95% CI, 1.44-4.17]; P=0.001), whereas hemodynamic Perceval performance was better (transvalvular gradient 23.42 +/- 1.73 versus 22.8 +/- 1.86; mean difference: 0.90 [95% CI, 0.62-1.18]; P=0.001), even during follow-up (10.98 +/- 5.7 versus 13.06 +/- 6.2; mean difference: -2.08 [95% CI, -3.96 to -0.21]; P=0.030). We found no difference in 1-year mortality

    CONTAMINATION INTEGRATE VULNERABILITY MAP FOR KARST AQUIFER OF SCIRCA SPRING (MONTE CUCCO, PERUGIA)

    No full text
    Carta a colori 100x70 cm, alla scala 1:10.000. Pubb. n. 2814 del GNDCI, LR4. Stella Arti Grafiche,

    Viscoelastic Blood Tests Use in Adult Cardiac Surgery: Meta-Analysis, Meta-Regression, and Trial Sequential Analysis

    No full text
    Objectives: Postoperative hemorrhage in cardiac surgery is a significant cause of morbidity and mortality. Standard laboratory tests fail as predictors for bleeding in the surgical setting. The use of viscoelastic (VE) hemostatic assays thromboelastography (TEG) and rotational thromboelastometry (ROTEM) could be an advantage in patients undergoing cardiac surgery. The objective of this meta-analysis was to analyze the effects (benefits and harms) of VE-guided transfusion practice in cardiac surgery patients. Design: A meta-analysis of randomized trials. Setting: For this study, PubMed, EMBASE, Scopus, and the Cochrane Collaboration database were searched, and only randomized controlled trials were included. A systematic review and meta-analysis were performed in accordance with the standards set forth by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement, using a random-effects model. Participants: The study comprised adult cardiac surgery patients. Interventions: VE-hemostatic assays transfusion algorithm compared with transfusion algorithms based on clinicians\u2019 discretion. Measurements and Main Results: Seven comparative randomized controlled trials were considered, including a total of 1,035 patients (522 patients in whom a TEG- or ROTEM-based transfusion algorithm was used). In patients treated according to VE-guided algorithms, red blood cell (odds ratio 0.61; 95% confidence interval [CI]: 0.37-0.99; p: 0.04; I2: 66%) and fresh frozen plasma transfusions (risk difference 0.22; 95% CI: 0.11-0.33; p < 0.0001; I2: 79%) use was reduced; platelets transfusion was not reduced (odds ratio 0.61; 95% CI: 0.32-1.15; p: 0.12; I2 74%). Conclusions: This study demonstrated that the use of VE assays in cardiac surgical patients is effective in reducing allogenic blood products exposure, postoperative bleeding at 12 and 24 hours after surgery, and the need for redo surgery unrelated to surgical bleeding

    Trans-axillary versus trans - aortic approach for transcatheter aortic valve implantation with corevalve revalving system: insights from multicenter experience

    No full text
    About one-third of candidates for transcatheter aortic valve implantation (TAVI) suffer from severe peripheral artery disease, making the routine femoral approach difficult or impossible. Aim was to compare the trans-axillary (TAx) and the trans-aortic (TAo) route for TAVI with Medtronic CoreValve Revalving System (CRS)
    corecore