1,961 research outputs found

    Statistical assessment of the impact of renewable energy sources on transient stability

    Get PDF
    This paper studies the impact of penetration of Renewable Energy Sources (RES) on the dynamic behavior of large power systems. Statistical analysis of the number of instabilities and the time of occurrence of loss of synchronism in the network was performed following large number of Monte Carlo simulations and considering high degrees of uncertainty. A criterion for instability detection is introduced. Conclusions are drawn with respect to the influence of RES on transient stability, the identification of critical generators and how these generators and their behavior may change for a wide range of RES penetration levels

    A wavelet based synchronized waveform measurement unit algorithm

    Get PDF
    Power systems with high penetrations of inverter-based resources are increasingly vulnerable to severe disturbances which may manifest as non-stationary voltage and current waveforms, presenting challenges to phasor measurement units which assume quasi-stationary conditions. Time synchronized, high-resolution, waveform measurements have emerged as a solution to accurately monitor emerging system dynamics. This paper proposes a synchronized waveform measurement unit algorithm to detect and characterize transient and dynamic phenomena present in synchronized waveform measurements. The proposed method utilizes the discrete wavelet packet transform to represent non-sinusoidal transients, while the adaptive empirical wavelet transform is applied to extract the fundamental and possible oscillation components. Finally, dynamic phasor extraction is performed via the Hilbert transform. The performance of the proposed algorithm is evaluated using synthetic test signals and compared to a phasor measurement unit algorithm using a goodness of fit metric. The results indicate that the proposed method produces an accurate and sparse representation of the underlying signal dynamics. The proposed method can potentially reduce communication requirements associated with high resolution synchronized waveform measurements, thus enabling real-time synchronized waveform-based applications

    Accurate microRNA target prediction correlates with protein repression levels

    Get PDF
    MicroRNAs are small endogenously expressed non-coding RNA molecules that regulate target gene expression through translation repression or messenger RNA degradation. MicroRNA regulation is performed through pairing of the microRNA to sites in the messenger RNA of protein coding genes. Since experimental identification of miRNA target genes poses difficulties, computational microRNA target prediction is one of the key means in deciphering the role of microRNAs in development and diseas

    Colorectal cancer screening awareness among physicians in Greece

    Get PDF
    BACKGROUND: Data comparison between SEER and EUROCARE database provided evidence that colorectal cancer survival in USA is higher than in European countries. Since adjustment for stage at diagnosis markedly reduces the survival differences, a screening bias was hypothesized. Considering the important role of primary care in screening activities, the purpose of the study was to investigate the colorectal cancer screening awareness among Hellenic physicians. METHODS: 211 primary care physicians were surveyed by mean of a self-reported prescription-habits questionnaire. Both physicians' colorectal cancer screening behaviors and colorectal cancer screening recommendations during usual check-up visits were analyzed. RESULTS: Only 50% of physicians were found to recommend screening for colorectal cancer during usual check-up visits, and only 25% prescribed cost-effective procedures. The percentage of physicians recommending stool occult blood test and sigmoidoscopy was 24% and 4% respectively. Only 48% and 23% of physicians recognized a cancer screening value for stool occult blood test and sigmoidoscopy. Colorectal screening recommendations were statistically lower among physicians aged 30 or less (p = 0.012). No differences were found when gender, level and type of specialization were analyzed, even though specialists in general practice showed a trend for better prescription (p = 0.054). CONCLUSION: Contemporary recommendations for colorectal cancer screening are not followed by implementation in primary care setting. Education on presymptomatic control and screening practice monitoring are required if primary care is to make a major impact on colorectal cancer mortality

    MRC chronic Dyspnea Scale: Relationships with cardiopulmonary exercise testing and 6-minute walk test in idiopathic pulmonary fibrosis patients: a prospective study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Exertional dyspnea is the most prominent and disabling feature in idiopathic pulmonary fibrosis (IPF). The Medical Research Chronic (MRC) chronic dyspnea score as well as physiological measurements obtained during cardiopulmonary exercise testing (CPET) and the 6-minute walk test (6MWT) are shown to provide information on the severity and survival of disease.</p> <p>Methods</p> <p>We prospectively recruited IPF patients and examined the relationship between the MRC score and either CPET or 6MWT parameters known to reflect physiologic derangements limiting exercise capacity in IPF patients</p> <p>Results</p> <p>Twenty-five patients with IPF were included in the study. Significant correlations were found between the MRC score and the distance (r = -.781, p < 0.001), the SPO<sub>2 </sub>at the initiation and the end (r = -.542, p = 0.005 and r = -.713, p < 0.001 respectively) and the desaturation index (r = .634, p = 0.001) for the 6MWT; the MRC score and <it>V</it>O<sub>2 </sub>peak/kg (r = -.731, p < 0.001), SPO<sub>2 </sub>at peak exercise (r = -. 682, p < 0.001), VE/VCO<sub>2 </sub>slope (r = .731, p < 0.001), VE/VCO<sub>2 </sub>at AT (r = .630, p = 0.002) and the Borg scale at peak exercise (r = .50, p = 0.01) for the CPET. In multiple logistic regression analysis, the only variable independently related to the MRC is the distance walked at the 6MWT.</p> <p>Conclusion</p> <p>In this population of IPF patients a good correlation was found between the MRC chronic dyspnoea score and physiological parameters obtained during maximal and submaximal exercise testing known to reflect ventilatory impairment and exercise limitation as well as disease severity and survival. This finding is described for the first time in the literature in this group of patients as far as we know and could explain why a simple chronic dyspnea score provides reliable prognostic information on IPF.</p

    Towards an end-to-end analysis and prediction system for weather, climate, and marine applications in the Red Sea

    Get PDF
    Author Posting. © American Meteorological Society, 2021. This article is posted here by permission of American Meteorological Society for personal use, not for redistribution. The definitive version was published in Bulletin of the American Meteorological Society 102(1), (2021): E99-E122, https://doi.org/10.1175/BAMS-D-19-0005.1.The Red Sea, home to the second-longest coral reef system in the world, is a vital resource for the Kingdom of Saudi Arabia. The Red Sea provides 90% of the Kingdom’s potable water by desalinization, supporting tourism, shipping, aquaculture, and fishing industries, which together contribute about 10%–20% of the country’s GDP. All these activities, and those elsewhere in the Red Sea region, critically depend on oceanic and atmospheric conditions. At a time of mega-development projects along the Red Sea coast, and global warming, authorities are working on optimizing the harnessing of environmental resources, including renewable energy and rainwater harvesting. All these require high-resolution weather and climate information. Toward this end, we have undertaken a multipronged research and development activity in which we are developing an integrated data-driven regional coupled modeling system. The telescopically nested components include 5-km- to 600-m-resolution atmospheric models to address weather and climate challenges, 4-km- to 50-m-resolution ocean models with regional and coastal configurations to simulate and predict the general and mesoscale circulation, 4-km- to 100-m-resolution ecosystem models to simulate the biogeochemistry, and 1-km- to 50-m-resolution wave models. In addition, a complementary probabilistic transport modeling system predicts dispersion of contaminant plumes, oil spill, and marine ecosystem connectivity. Advanced ensemble data assimilation capabilities have also been implemented for accurate forecasting. Resulting achievements include significant advancement in our understanding of the regional circulation and its connection to the global climate, development, and validation of long-term Red Sea regional atmospheric–oceanic–wave reanalyses and forecasting capacities. These products are being extensively used by academia, government, and industry in various weather and marine studies and operations, environmental policies, renewable energy applications, impact assessment, flood forecasting, and more.The development of the Red Sea modeling system is being supported by the Virtual Red Sea Initiative and the Competitive Research Grants (CRG) program from the Office of Sponsored Research at KAUST, Saudi Aramco Company through the Saudi ARAMCO Marine Environmental Center at KAUST, and by funds from KAEC, NEOM, and RSP through Beacon Development Company at KAUST

    Documenting the Recovery of Vascular Services in European Centres Following the Initial COVID-19 Pandemic Peak: Results from a Multicentre Collaborative Study

    Get PDF
    Objective: To document the recovery of vascular services in Europe following the first COVID-19 pandemic peak. Methods: An online structured vascular service survey with repeated data entry between 23 March and 9 August 2020 was carried out. Unit level data were collected using repeated questionnaires addressing modifications to vascular services during the first peak (March – May 2020, “period 1”), and then again between May and June (“period 2”) and June and July 2020 (“period 3”). The duration of each period was similar. From 2 June, as reductions in cases began to be reported, centres were first asked if they were in a region still affected by rising cases, or if they had passed the peak of the first wave. These centres were asked additional questions about adaptations made to their standard pathways to permit elective surgery to resume. Results: The impact of the pandemic continued to be felt well after countries’ first peak was thought to have passed in 2020. Aneurysm screening had not returned to normal in 21.7% of centres. Carotid surgery was still offered on a case by case basis in 33.8% of centres, and only 52.9% of centres had returned to their normal aneurysm threshold for surgery. Half of centres (49.4%) believed their management of lower limb ischaemia continued to be negatively affected by the pandemic. Reduced operating theatre capacity continued in 45.5% of centres. Twenty per cent of responding centres documented a backlog of at least 20 aortic repairs. At least one negative swab and 14 days of isolation were the most common strategies used for permitting safe elective surgery to recommence. Conclusion: Centres reported a broad return of services approaching pre-pandemic “normal” by July 2020. Many introduced protocols to manage peri-operative COVID-19 risk. Backlogs in cases were reported for all major vascular surgeries

    Energy Resolution Performance of the CMS Electromagnetic Calorimeter

    Get PDF
    The energy resolution performance of the CMS lead tungstate crystal electromagnetic calorimeter is presented. Measurements were made with an electron beam using a fully equipped supermodule of the calorimeter barrel. Results are given both for electrons incident on the centre of crystals and for electrons distributed uniformly over the calorimeter surface. The electron energy is reconstructed in matrices of 3 times 3 or 5 times 5 crystals centred on the crystal containing the maximum energy. Corrections for variations in the shower containment are applied in the case of uniform incidence. The resolution measured is consistent with the design goals
    corecore