1,124 research outputs found

    The use of curved vs. straight instruments in single port access surgery, on standardized box trainer tasks

    Get PDF
    BACKGROUND: Single-port access (SPA) surgery is a novel surgical technique to create nearly "scarless" surgery. SPA surgery appears to be safe and feasible, but the exposure and handling of tissue may not be optimal. Therefore, the performance of SPA surgery with different instruments used and conventional laparoscopy is compared. METHODS: Fifteen participants (>50 laparoscopic procedures) performed three basic tasks (translocation, clip & cut, and tissue dissection, based on the fundamentals of laparoscopic surgery) in the box trainer in laparoscopy and SPA settings with both (conventional) crossed and curved instruments. All participants completed a questionnaire, which asked their opinion on the use of instruments and preference. RESULTS: Translocation was performed significantly faster in both laparoscopy and SPA crossed than SPA curved (means, 130.3 and 137.7 vs. 170.7 sec; p < 0.001 and p = 0.005). The errors also were less in laparoscopy and SPA crossed (means, 0.9 and 1.2 vs. 1.6), but not significant. The time to complete the dissection was almost equal between laparoscopy and SPA curved settings, but took longer for SPA crossed, although not significantly (148.1 and 150.8 vs. 179.5 sec). The errors only differed significantly between laparoscopy and SPA crossed (means, 0.5 vs. 1.27; p = 0.044). Fourteen participants still favored conventional laparoscopy and one SPA curved. They also thought SPA curved was better than crossed (means, 3.6 vs. 2.47; p = 0.003) and that exposure is superior in curved (means, 3.4 vs. 2.27; p = 0.002). CONCLUSIONS: Although conventional laparoscopy may appear most effective for proper dissection and exposure of tissue, single-port access surgery shows potential. Especially in the tissue dissection task, there is no significant difference in time or errors between conventional laparoscopy and SPA surgery, using specially designed curved instruments. Although the participants favor conventional laparoscopy, this could evolve to a more accepting mind when SPA surgery becomes more available and used in the clinical setting

    First administration to man of Org 25435, an intravenous anaesthetic: A Phase 1 Clinical Trial

    Get PDF
    BACKGROUND: Org 25435 is a new water-soluble alpha-amino acid ester intravenous anaesthetic which proved satisfactory in animal studies. This study aimed to assess the safety, tolerability and efficacy of Org 25435 and to obtain preliminary pharmacodynamic and pharmacokinetic data. METHODS: In the Short Infusion study 8 healthy male volunteers received a 1 minute infusion of 0.25, 0.5, 1.0, or 2.0 mg/kg (n = 2 per group); a further 10 received 3.0 mg/kg (n = 5) or 4.0 mg/kg (n = 5). Following preliminary pharmacokinetic modelling 7 subjects received a titrated 30 minute Target Controlled Infusion (TCI), total dose 5.8-20 mg/kg. RESULTS: Within the Short Infusion study, all subjects were successfully anaesthetised at 3 and 4 mg/kg. Within the TCI study 5 subjects were anaesthetised and 2 showed signs of sedation. Org 25435 caused hypotension and tachycardia at doses over 2 mg/kg. Recovery from anaesthesia after a 30 min administration of Org 25435 was slow (13.7 min). Pharmacokinetic modelling suggests that the context sensitive half-time of Org 25435 is slightly shorter than that of propofol in infusions up to 20 minutes but progressively longer thereafter. CONCLUSIONS: Org 25435 is an effective intravenous anaesthetic in man at doses of 3 and 4 mg/kg given over 1 minute. Longer infusions can maintain anaesthesia but recovery is slow. Hypotension and tachycardia during anaesthesia and slow recovery of consciousness after cessation of drug administration suggest this compound has no advantages over currently available intravenous anaesthetics

    Short-term efficacy of physical interventions in osteoarthritic knee pain. A systematic review and meta-analysis of randomised placebo-controlled trials.

    Get PDF
    BACKGROUND: Treatment efficacy of physical agents in osteoarthritis of the knee (OAK) pain has been largely unknown, and this systematic review was aimed at assessing their short-term efficacies for pain relief. METHODS: Systematic review with meta-analysis of efficacy within 1-4 weeks and at follow up at 1-12 weeks after the end of treatment. RESULTS: 36 randomised placebo-controlled trials (RCTs) were identified with 2434 patients where 1391 patients received active treatment. 33 trials satisfied three or more out of five methodological criteria (Jadad scale). The patient sample had a mean age of 65.1 years and mean baseline pain of 62.9 mm on a 100 mm visual analogue scale (VAS). Within 4 weeks of the commencement of treatment manual acupuncture, static magnets and ultrasound therapies did not offer statistically significant short-term pain relief over placebo. Pulsed electromagnetic fields offered a small reduction in pain of 6.9 mm [95% CI: 2.2 to 11.6] (n = 487). Transcutaneous electrical nerve stimulation (TENS, including interferential currents), electro-acupuncture (EA) and low level laser therapy (LLLT) offered clinically relevant pain relieving effects of 18.8 mm [95% CI: 9.6 to 28.1] (n = 414), 21.9 mm [95% CI: 17.3 to 26.5] (n = 73) and 17.7 mm [95% CI: 8.1 to 27.3] (n = 343) on VAS respectively versus placebo control. In a subgroup analysis of trials with assumed optimal doses, short-term efficacy increased to 22.2 mm [95% CI: 18.1 to 26.3] for TENS, and 24.2 mm [95% CI: 17.3 to 31.3] for LLLT on VAS. Follow-up data up to 12 weeks were sparse, but positive effects seemed to persist for at least 4 weeks after the course of LLLT, EA and TENS treatment was stopped. CONCLUSION: TENS, EA and LLLT administered with optimal doses in an intensive 2-4 week treatment regimen, seem to offer clinically relevant short-term pain relief for OAK

    RingCT 2.0: A Compact Accumulator-Based (Linkable Ring Signature) Protocol for Blockchain Cryptocurrency Monero

    Get PDF
    In this work, we initially study the necessary properties and security requirements of Ring Confidential Transaction (RingCT) protocol deployed in the popular anonymous cryptocurrency Monero. Firstly, we formalize the syntax of RingCT protocol and present several formal security definitions according to its application in Monero. Based on our observations on the underlying (linkable) ring signature and commitment schemes, we then put forward a new efficient RingCT protocol (RingCT 2.0), which is built upon the well-known Pedersen commitment, accumulator with one-way domain and signature of knowledge (which altogether perform the functions of a linkable ring signature). Besides, we show that it satisfies the security requirements if the underlying building blocks are secure in the random oracle model. In comparison with the original RingCT protocol, our RingCT 2.0 protocol presents a significant space saving, namely, the transaction size is independent of the number of groups of input accounts included in the generalized ring while the original RingCT suffers a linear growth with the number of groups, which would allow each block to process more transactions

    Adding Linkability to Ring Signatures with One-Time Signatures

    Get PDF
    We propose a generic construction that adds linkability to any ring signature scheme with one-time signature scheme. Our construction has both theoretical and practical interest. In theory, the construction gives a formal and cleaner description for constructing linkable ring signature from ring signature directly. In practice, the transformation incurs a tiny overhead in size and running time. By instantiating our construction using the ring signature scheme (ACNS 2019) and the one-time signature scheme (TCHES 2018), we obtain a lattice-based linkable ring signature scheme whose signature size is logarithmic in the number of ring members. This scheme is practical, especially the signature size is very short: for 2302^{30} ring members and 100 bit security, our signature size is only 4 MB. In addition, when proving the linkability we develop a new proof technique in the random oracle model, which might be of independent interes

    How to juggle priorities? An interactive tool to provide quantitative support for strategic patient-mix decisions: an ophthalmology case

    Get PDF
    An interactive tool was developed for the ophthalmology department of the Academic Medical Center to quantitatively support management with strategic patient-mix decisions. The tool enables management to alter the number of patients in various patient groups and to see the consequences in terms of key performance indicators. In our case study, we focused on the bottleneck: the operating room. First, we performed a literature review to identify all factors that influence an operating room's utilization rate. Next, we decided which factors were relevant to our study. For these relevant factors, two quantitative methods were applied to quantify the impact of an individual factor: regression analysis and computer simulation. Finally, the average duration of an operation, the number of cancellations due to overrun of previous surgeries, and the waiting time target for elective patients all turned out to have significant impact. Accordingly, for the case study, the interactive tool was shown to offer management quantitative decision support to act proactively to expected alterations in patient-mix. Hence, management can anticipate the future situation, and either alter the expected patient-mix or expand capacity to ensure that the key performance indicators will be met in the future

    Observation of the exceptional-point-enhanced Sagnac effect

    Get PDF
    Exceptional points (EPs) are special spectral degeneracies of non-Hermitian Hamiltonians that govern the dynamics of open systems. At an EP, two or more eigenvalues, and the corresponding eigenstates, coalesce. Recently, it was predicted that operation of an optical gyroscope near an EP results in improved response to rotations. However, the performance of such a system has not been examined experimentally. Here we introduce a precisely controllable physical system for the study of non-Hermitian physics and nonlinear optics in high-quality-factor microresonators. Because this system dissipatively couples counter-propagating lightwaves within the resonator, it also functions as a sensitive gyroscope for the measurement of rotations. We use our system to investigate the predicted EP-enhanced Sagnac effect and observe a four-fold increase in the Sagnac scale factor by directly measuring rotations applied to the resonator. The level of enhancement can be controlled by adjusting the system bias relative to the EP, and modelling results confirm the observed enhancement. Moreover, we characterize the sensitivity of the gyroscope near the EP. Besides verifying EP physics, this work is important for the understanding of optical gyroscopes
    corecore