2,632 research outputs found

    Long-term visual and microperimetry outcomes following autologous retinal pigment epithelium choroid graft for neovascular age-related macular degeneration

    Get PDF
    To describe the 2- to 4-year visual and microperimetry outcomes of autologous retinal pigment epithelium (RPE)-choroid graft in patients with neovascular age-related macular degeneration (AMD).In this retrospective cohort study, 12 patients with subfoveal neovascular AMD who had undergone autologous RPE-choroid graft between August 2004 and June 2005 were reviewed. Change in visual acuity (VA), contrast sensitivity (CS), fixation stability and retinal sensitivity on microperimetry after 2-3 years and the rates of late postoperative complications were examined.Patients were followed for 26-48 months (mean, 39). Median preoperative VA (logMAR) was 0.87 but declined to 1.43 (1 year), 1.46 (2 years) and 1.38 (3 years), P = 0.001. Median CS (logCS) was 0.75 preoperatively but declined to 0.45 at 2 years. Six patients had serial microperimetry. Fixation stability declined in 1 but improved in 2 patients. All 6 had decline in retinal sensitivity over the graft during follow up. Retinal detachment did not occur after 12 months but 8 developed epiretinal membrane, 12 had cystic retinal change over the graft and 4 developed recurrent choroidal neovascularization. However, 10 grafts retained autofluorescence signal at 18-48 months of follow up.Autologous RPE-choroid graft can maintain VA, stable fixation and retinal sensitivity in some patients for over 3 years. The spatial correlation between graft autofluorescence, outer retinal structures on optical coherence tomography and retinal sensitivity are consistent with photoreceptor cell rescue. However, we caution the use of this technique as there is high complication rate and delayed loss of retinal function

    Far-UV HST Spectroscopy of an Unusual Hydrogen-poor Superluminous Supernova: SN2017egm

    Get PDF
    SN2017egm is the closest (z = 0.03) H-poor superluminous supernova (SLSN-I) detected to date, and a rare example of an SLSN-I in a massive, metal-rich galaxy. We present the HST UV and optical spectra covering 1000–5500 Å, taken at +3 day relative to the peak. Our data reveal two absorption systems at redshifts matching the host galaxy NGC 3191 (z = 0.0307) and its companion galaxy (z = 0.0299) 73'' apart. Weakly damped Lyα absorption lines are detected at these two redshifts, with H i column densities of (3.0 ± 0.8) × 1019 and (3.7 ± 0.9) × 1019 cm−2, respectively. This is an order of magnitude smaller than the H i column densities in the disks of nearby galaxies (>1010 M ⊙) and suggests that SN2017egm is on the near side of NGC 3191 and has a low host extinction (E(B − V) ~ 0.007). Using unsaturated metal absorption lines, we find that the host of SN2017egm probably has a solar or higher metallicity and is unlikely to be a dwarf companion to NGC 3191. Comparison of early-time UV spectra of SN2017egm, Gaia16apd, iPTF13ajg, and PTF12dam finds that the continuum at λ > 2800 Å is well fit by a blackbody, whereas the continuum at λ < 2800 Å is considerably below the model. The degree of UV suppression varies from source to source, with the 1400–2800 Å continuum flux ratio of 1.5 for Gaia16apd and 0.4 for iPTF13ajg. This cannot be explained by the differences in magnetar power or blackbody temperature. Finally, the UV spectra reveal a common set of seven broad absorption features and their equivalent widths are similar (within a factor of 2) among the four events

    Modelling Cost Effectiveness in Neovascular Age-Related Macular Degeneration: The Impact of Using Contrast Sensitivity vs. Visual Acuity.

    Get PDF
    The cost utility of treatments of age-related macular degeneration (AMD) is commonly assessed using health state transition models defined by levels of visual acuity. However, there is evidence that another measure of visual function, contrast sensitivity, may be better associated with utility than visual acuity. This paper investigates the difference in cost effectiveness resulting from models based on visual acuity and contrast sensitivity using the example of bevacizumab (Avastin) for neovascular AMD. The implications of the choice of outcome on structural uncertainty in the model are investigated

    Multiple Imputation Ensembles (MIE) for dealing with missing data

    Get PDF
    Missing data is a significant issue in many real-world datasets, yet there are no robust methods for dealing with it appropriately. In this paper, we propose a robust approach to dealing with missing data in classification problems: Multiple Imputation Ensembles (MIE). Our method integrates two approaches: multiple imputation and ensemble methods and compares two types of ensembles: bagging and stacking. We also propose a robust experimental set-up using 20 benchmark datasets from the UCI machine learning repository. For each dataset, we introduce increasing amounts of data Missing Completely at Random. Firstly, we use a number of single/multiple imputation methods to recover the missing values and then ensemble a number of different classifiers built on the imputed data. We assess the quality of the imputation by using dissimilarity measures. We also evaluate the MIE performance by comparing classification accuracy on the complete and imputed data. Furthermore, we use the accuracy of simple imputation as a benchmark for comparison. We find that our proposed approach combining multiple imputation with ensemble techniques outperform others, particularly as missing data increases

    Temperature variations from Hubble Space Telescope imagery and spectroscopy of NGC 7009

    Get PDF
    We present new Hubble Space Telescope (HST)/WFPC2 imagery and STIS long-slit spectroscopy of the planetary nebula NGC 7009. The primary goal was to obtain high spatial resolution of the intrinsic line ratio [O III] 4364/5008 and thereby evaluate the electron temperature (Te) and the fractional mean-square Te variation (tA2)across the nebula. The WFPC2 Te map is rather uniform; almost all values are between 9000–11 000 K, with the higher Te values closely coinciding with the inner He++ zone. The results indicate very small values–≲0.01– for tA2 throughout. Our STIS data allow an even more direct determination of Te and tA2, albeit for a much smaller area than with WFPC2. We present results from binning the data along the slit into tiles that are 0.5-arcsec square (matching the slit width). The average [O III] temperature using 45 tiles (excluding the central star and STIS fiducial bars) is 10 139 K; tA2 is 0.0035. The measurements of Te reported here are an average along each line of sight. Therefore, despite finding remarkably low tA2, we cannot completely rule out temperature fluctuations along the line of sight as the cause of the large abundance discrepancy between heavy element abundances inferred from collisionally excited emission lines compared to those derived from recombination lines

    Investigating the missing data mechanism in quality of life outcomes: a comparison of approaches

    Get PDF
    Background: Missing data is classified as missing completely at random (MCAR), missing at random (MAR) or missing not at random (MNAR). Knowing the mechanism is useful in identifying the most appropriate analysis. The first aim was to compare different methods for identifying this missing data mechanism to determine if they gave consistent conclusions. Secondly, to investigate whether the reminder-response data can be utilised to help identify the missing data mechanism. Methods: Five clinical trial datasets that employed a reminder system at follow-up were used. Some quality of life questionnaires were initially missing, but later recovered through reminders. Four methods of determining the missing data mechanism were applied. Two response data scenarios were considered. Firstly, immediate data only; secondly, all observed responses (including reminder-response). Results: In three of five trials the hypothesis tests found evidence against the MCAR assumption. Logistic regression suggested MAR, but was able to use the reminder-collected data to highlight potential MNAR data in two trials. Conclusion: The four methods were consistent in determining the missingness mechanism. One hypothesis test was preferred as it is applicable with intermittent missingness. Some inconsistencies between the two data scenarios were found. Ignoring the reminder data could potentially give a distorted view of the missingness mechanism. Utilising reminder data allowed the possibility of MNAR to be considered.The Chief Scientist Office of the Scottish Government Health Directorate. Research Training Fellowship (CZF/1/31

    Quantum states made to measure

    Full text link
    Recent progress in manipulating quantum states of light and matter brings quantum-enhanced measurements closer to prospective applications. The current challenge is to make quantum metrologic strategies robust against imperfections.Comment: 4 pages, 3 figures, Commentary for Nature Photonic

    Towards causal benchmarking of bias in face analysis algorithms

    Get PDF
    Measuring algorithmic bias is crucial both to assess algorithmic fairness, and to guide the improvement of algorithms. Current methods to measure algorithmic bias in computer vision, which are based on observational datasets, are inadequate for this task because they conflate algorithmic bias with dataset bias. To address this problem we develop an experimental method for measuring algorithmic bias of face analysis algorithms, which manipulates directly the attributes of interest, e.g., gender and skin tone, in order to reveal causal links between attribute variation and performance change. Our proposed method is based on generating synthetic ``transects'' of matched sample images that are designed to differ along specific attributes while leaving other attributes constant. A crucial aspect of our approach is relying on the perception of human observers, both to guide manipulations, and to measure algorithmic bias. Besides allowing the measurement of algorithmic bias, synthetic transects have other advantages with respect to observational datasets: they sample attributes more evenly allowing for more straightforward bias analysis on minority and intersectional groups, they enable prediction of bias in new scenarios, they greatly reduce ethical and legal challenges, and they are economical and fast to obtain, helping make bias testing affordable and widely available. We validate our method by comparing it to a study that employs the traditional observational method for analyzing bias in gender classification algorithms. The two methods reach different conclusions. While the observational method reports gender and skin color biases, the experimental method reveals biases due to gender, hair length, age, and facial hair
    corecore