6,318 research outputs found

    The current use, and opinions of elite athletes and support staff in relation to genetic testing in elite sport within the UK

    Get PDF
    The purpose of the study was to investigate the current use of genetic testing in UK elite sport and assess how genetic testing might be received by those employed in elite sport. Seventy-two elite athletes and 95 support staff at UK sports clubs and governing bodies completed an online survey of 11 questions concerning their experience of genetic testing and beliefs regarding the use of genetic testing in sport. Genetic testing related to sports performance and injury susceptibility is conducted in UK elite sport, albeit by a relatively small proportion of athletes (≤17%) and support staff (≤8%). Athletes and their support staff agree that genetics are important in determining elite status (≥79%) and appear willing to engage in genetic testing for individualising training to improve sport performance and reduce injury risk. Opinion was divided on whether genetic information should be used to identify talented athletes and influence selection, eligibility or employment status. Genetic testing for sports performance and injury susceptibility occurs in UK elite sport, however it is not commonly conducted. There is a belief that genetics is an important factor in determining an athlete and there is a willingness to engage in genetic testing for sports performance and injury susceptibility

    Interobserver agreement in detecting spectral-domain optical coherence tomography features of diabetic macular edema

    Get PDF
    Purpose: To evaluate interobserver agreement for the detection of spectral-domain optical coherence tomography (SDOCT) features of diabetic macular edema (DME). Method: Cross-sectional study in which 2 retinal specialists evaluated SDOCT scans from eyes receiving treatment for DME. Scans from 50 eyes with DME of 39 patients were graded for features of DME including intra-retinal fluid (IRF), diffuse retinal oedema (DRE), hyper-reflective foci (HRF), subretinal fluid (SRF), macular fluid and vitreomacular traction (VMT). Features were graded as present or absent at zones involving the fovea, 1mm from the fovea and the whole scan of 49 line scans. Analysis was performed using cross-tabulations for percentage concordance and kappa values (κ). Results: In the 2950 line scans analysed, there was an increase in percentage concordance for DRE and HRF when moving from a foveal line scan, 1mm zone and then to a whole scan analysis (88% vs 94% vs 96%) and (88% vs 94% vs 94%) respectively with κ ranging from substantial to almost perfect. Percentage concordance for SRF was 96% at all 3 regions analysed, whilst IRF was 96% at fovea and 98% at higher number of line-scans analysed. Concordance for MF was 100% at fovea and 98% at 1mm zone and whole scan with almost perfect and substantial κ respectively. κ agreement was substantial for VMT at all regions analysed. Conclusion: We report a high level of interobserver agreement in the detection of SDOCT features of DME. This finding is important as detection of macular fluid is used to guide retreatment with anti-angiogenic agents

    A review of the clinical utility of the Enhanced Liver Fibrosis test in multiple aetiologies of chronic liver disease

    Get PDF
    The rising incidence of chronic liver disease continues to be an increasing health burden. The morbidity and mortality associated with chronic liver disease typically occur in patients with advanced fibrosis. Hence, early identification of those at-risk is of vital importance to ensure appropriate ongoing management. Currently, tools for appropriate risk stratification remain limited. Increasing awareness of the limitations of liver biopsy has driven research into alternative non-invasive methods of fibrosis assessment including serological markers assessing functional changes. One such biomarker, the Enhanced Liver Fibrosis test, was initially validated in a cohort of 1021 patients with mixed aetiology chronic liver disease and shown to perform well. Since this pathfinder study, it has been independently validated in cohorts of hepatitis C, non-alcoholic fatty liver disease, alcoholic liver disease, primary biliary cirrhosis and primary sclerosing cholangitis. In addition to performing well as a diagnostic tool, the Enhanced Liver Fibrosis test has been shown to outperform liver biopsy in prognostic studies and is the only non-invasive marker to do so. However, questions remain regarding the use of this test, particularly regarding the possible effect age and alcohol may have on test scores. This review examines the current literature published in relation to the Enhanced Liver Fibrosis test and its clinical utility and highlights areas requiring further study

    Optical Coherence Tomography in the UK Biobank Study - Rapid Automated Analysis of Retinal Thickness for Large Population-Based Studies

    Get PDF
    PURPOSE: To describe an approach to the use of optical coherence tomography (OCT) imaging in large, population-based studies, including methods for OCT image acquisition, storage, and the remote, rapid, automated analysis of retinal thickness. METHODS: In UK Biobank, OCT images were acquired between 2009 and 2010 using a commercially available “spectral domain” OCT device (3D OCT-1000, Topcon). Images were obtained using a raster scan protocol, 6 mm x 6 mm in area, and consisting of 128 B-scans. OCT image sets were stored on UK Biobank servers in a central repository, adjacent to high performance computers. Rapid, automated analysis of retinal thickness was performed using custom image segmentation software developed by the Topcon Advanced Biomedical Imaging Laboratory (TABIL). This software employs dual-scale gradient information to allow for automated segmentation of nine intraretinal boundaries in a rapid fashion. RESULTS: 67,321 participants (134,642 eyes) in UK Biobank underwent OCT imaging of both eyes as part of the ocular module. 134,611 images were successfully processed with 31 images failing segmentation analysis due to corrupted OCT files or withdrawal of subject consent for UKBB study participation. Average time taken to call up an image from the database and complete segmentation analysis was approximately 120 seconds per data set per login, and analysis of the entire dataset was completed in approximately 28 days. CONCLUSIONS: We report an approach to the rapid, automated measurement of retinal thickness from nearly 140,000 OCT image sets from the UK Biobank. In the near future, these measurements will be publically available for utilization by researchers around the world, and thus for correlation with the wealth of other data collected in UK Biobank. The automated analysis approaches we describe may be of utility for future large population-based epidemiological studies, clinical trials, and screening programs that employ OCT imaging

    High-resolution laboratory lysimeter for automated sampling of tracers through a 0.5m soil block

    Get PDF
    A computer-controlled, automated sample collection from a 0.5-m lysimeter, designed to give superior temporal and spatial resolution for monitoring the movement of chemical tracers through a large undisturbed soil block, is described. The soil block, 0.520.520.5 m, was monitored for saturation using eight time domain reflectometry probes. Rainfall was applied at approximately 1600 ml hm1 using a 12212 array of 23-gauge (0.318 mm internal diameter) hypodermic needles. Soil leachates were collected at the base of the soil block using a machined aluminium collection plate with a 10210 grid of funnels that passed leachates to sample collection palettes. Sample collection was automated using a personal computer equipped with National Instruments LabVIEW™ software and linked to sensors for palette tracking. The automation of the lysimeter allowed sample collection and storage over a user-defined period with no human interaction. As an example of the use of the automated lysimeter, results show the distribution of phosphate within the soil. The eluted phosphate showed an initial and secondary peak, and only emerged from preferential flow channels

    Diffusion tensor imaging reveals changes in microstructural integrity along compressed nerve roots that correlate with chronic pain symptoms and motor deficiencies in elderly stenosis patients

    Get PDF
    Age-related degenerative changes in the lumbar spine frequently result in nerve root compression causing severe pain and disability. Given the increasing incidence of lumbar spinal disorders in the aging population and the discrepancies between the use of current diagnostic imaging tools and clinical symptoms, novel methods of nerve root assessment are needed. We investigated elderly patients with stenosis at L4-L5 or L5-S1 levels. Diffusion tensor imaging (DTI) was used to quantify microstructure in compressed L5 nerve roots and investigate relationships to clinical symptoms and motor neurophysiology. DTI metrics (i.e. FA, MD, AD and RD) were measured at proximal, mid and distal segments along compressed (i.e. L5) and intact (i.e. L4 or S1) nerve roots. FA was significantly reduced in compressed nerve roots and MD, AD and RD were significantly elevated in the most proximal segment of the nerve root studied. FA was significantly correlated with electrophysiological measures of root function: minimum F-wave latency and peripheral motor conduction time (PMCT). In addition, FA along the compressed root also correlated with leg pain and depression score. There was also a relationship between RD and anxiety, leg pain and disability score and AD correlated with depression score. Taken together, these data show that DTI metrics are sensitive to nerve root compression in patients with stenosis as a result of age-related lumbar degeneration. Critically, they show that the changes in microstructural integrity along compressed L5 nerve roots are closely related to a number of clinical symptoms associated with the development of chronic pain as well as neurophysiological assessments of motor function. These inherent relationships between nerve root damage and phenotype suggest that the use DTI is a promising method as a way to stratify treatment selection and predict outcomes

    Self-administration of adrenaline for anaphylaxis during in-hospital food challenges improves health-related quality of life

    Get PDF
    Objective To assess the impact of anaphylaxis on health-related quality of life (HRQL) and self-efficacy in food-allergic patients undergoing in-hospital food challenge. Design Secondary analysis of a randomised controlled trial. Setting Specialist allergy centre. Patients Peanut-allergic young people aged 8–16 years. Interventions Double-blind, placebo-controlled food challenge to peanut, with HRQL and self-efficacy assessed using validated questionnaire, approximately 2 weeks prior to and 2 weeks after challenge. Where possible, anaphylaxis was treated with self-injected adrenaline (epinephrine). Main outcome measures Change in HRQL and self-efficacy. Results 56 participants had reactions at food challenge, of whom 16 (29%) had anaphylaxis. Overall, there was an improvement in HRQL (mean 2.6 points (95% CI 0.3 to 4.8); p=0.030) and self-efficacy (mean 4.1 points (95% CI 2.4 to 5.9); p<0.0001), independent of whether anaphylaxis occurred. Parents also reported improved HRQL (mean 10.3 points (95% CI 5.9 to 14.7); p<0.0001). We found evidence of discordance between the improvement in HRQL and self-efficacy as reported by young people and that perceived by parents in their child. Conclusions Anaphylaxis at food challenge, followed by self-administration of injected adrenaline, was associated with an increase in HRQL and self-efficacy in young people with peanut allergy. We found no evidence that the occurrence of anaphylaxis had a detrimental effect. Young people should be encouraged to self-administer adrenaline using their autoinjector device to treat anaphylaxis at in-hospital challenge. Trial registration number NCT0214971

    Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration

    Get PDF
    BACKGROUND: The aim was to determine the intrasession repeatability of swept-source optical coherence tomography (SS-OCT)-derived retinal and choroidal thickness measurements in eyes with neovascular age-related macular degeneration (nAMD). METHODS: A prospective study consisting of patients with active nAMD enrolled in the Distance of Choroid Study at Moorfields Eye Hospital, London. Patients underwent three 12×9 mm macular raster scans using the deep range imaging (DRI) OCT-1 SS-OCT (Topcon) device in a single imaging session. Retinal and choroidal thicknesses were calculated for the ETDRS macular subfields. Repeatability was calculated according to methods described by Bland and Altman. RESULTS: 39 eyes of 39 patients with nAMD were included with a mean (±SD) age of 73.9 (±7.2) years. The mean (±SD) retinal thickness of the central macular subfield was 225.7 μm (±12.4 μm). The repeatability this subfield, expressed as a percentage of the mean central macular subfield thickness, was 23.2%. The percentage repeatability of the other macular subfields ranged from 13.2% to 28.7%. The intrasession coefficient of repeatability of choroidal thickness of the central macular subfield was 57.2 μm with a mean choroidal thickness (±SD) of 181 μm (±15.8 μm). CONCLUSIONS: This study suggests that a change >23.2% of retinal thickness and 57.2 μm choroidal thickness in the central macular subfield is required to distinguish true clinical change from measurement variability when using the DRI OCT-1 device to manage patients with nAMD
    corecore