269 research outputs found

    A Web-Based Flexible Communication System in Radiology

    Get PDF
    A web-based system for rapid multidirectional communication has been created in the Radiology department at San Francisco General Hospital. The system allows messaging among radiology attendings, residents, and technologists, as well as other members of the hospital community, such as Emergency Department physicians and nurses. Instead of being tied to a particular workflow, this system provides a flexible communication infrastructure which can be easily adapted for different functions and user roles. The system has so far been configured to successfully support the standard “wet reading” workflow, to support marking and tracking of critical results, as well as multiple educational and quality improvement workflows. In the 19 months of operation, the system has gained over 1,800 users (virtually all providers at our institution), it has been accessed by radiologists over 39,000 times and by non-radiologists over 34,000 times. It has become an integral part of the radiology department operations and non-radiology clinical workflows. Unlike most existing softwares, our system is not a task-specific application, but a multipurpose communication system. It is able to effectively accommodate multiple workflows and user roles through configuration (without additional programming). This flexibility has helped this system to be rapidly and widely adopted within our enterprise. The extended reach of the system enables improved monitoring and documentation of workflows, helping with management decision making, and quality assurance. We report a successful radiology communication system based on the principles of flexibility and inclusiveness of users inside and outside the radiology department

    SWATH mass spectrometry as a tool for quantitative profiling of the matrisome.

    Get PDF
    Proteomic analysis of extracellular matrix (ECM) and ECM-associated proteins, collectively known as the matrisome, is a challenging task due to the inherent complexity and insolubility of these proteins. Here we present sequential window acquisition of all theoretical fragment ion spectra mass spectrometry (SWATH MS) as a tool for the quantitative analysis of matrisomal proteins in both non-enriched and ECM enriched tissue without the need for prior fractionation. Utilising a spectral library containing 201 matrisomal proteins, we compared the performance and reproducibility of SWATH MS over conventional data-dependent analysis mass spectrometry (DDA MS) in unfractionated murine lung and liver. SWATH MS conferred a 15-20% increase in reproducible peptide identification across replicate experiments in both tissue types and identified 54% more matrisomal proteins in the liver versus DDA MS. We further use SWATH MS to evaluate the quantitative changes in matrisome content that accompanies ECM enrichment. Our data shows that ECM enrichment led to a systematic increase in core matrisomal proteins but resulted in significant losses in matrisome-associated proteins including the cathepsins and proteins of the S100 family. Our proof-of-principle study demonstrates the utility of SWATH MS as a versatile tool for in-depth characterisation of the matrisome in unfractionated and non-enriched tissues. SIGNIFICANCE: The matrisome is a complex network of extracellular matrix (ECM) and ECM-associated proteins that provides scaffolding function to tissues and plays important roles in the regulation of fundamental cellular processes. However, due to its inherent complexity and insolubility, proteomic studies of the matrisome typically require the application of enrichment workflows prior to MS analysis. Such enrichment strategies often lead to losses in soluble matrisome-associated components. In this study, we present sequential window acquisition of all theoretical fragment ion spectra mass spectrometry (SWATH MS) as a tool for the quantitative analysis of matrisomal proteins. We show that SWATH MS provides a more reproducible coverage of the matrisome compared to data-dependent analysis (DDA) MS. We also demonstrate that SWATH MS is capable of accurate quantification of matrisomal proteins without prior ECM enrichment and fractionation, which may simplify sample handling workflows and avoid losses in matrisome-associated proteins commonly linked to ECM enrichment

    Comparison of exhaled breath condensate pH using two commercially available devices in healthy controls, asthma and COPD patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Analysis of exhaled breath condensate (EBC) is a non-invasive method for studying the acidity (pH) of airway secretions in patients with inflammatory lung diseases.</p> <p>Aim</p> <p>To assess the reproducibility of EBC pH for two commercially available devices (portable RTube and non-portable ECoScreen) in healthy controls, patients with asthma or COPD, and subjects suffering from an acute cold with lower-airway symptoms. In addition, we assessed the repeatability in healthy controls.</p> <p>Methods</p> <p>EBC was collected from 40 subjects (n = 10 in each of the above groups) using RTube and ECoScreen. EBC was collected from controls on two separate occasions within 5 days. pH in EBC was assessed after degasification with argon for 20 min.</p> <p>Results</p> <p>In controls, pH-measurements in EBC collected by RTube or ECoScreen showed no significant difference between devices (p = 0.754) or between days (repeatability coefficient RTube: 0.47; ECoScreen: 0.42) of collection. A comparison between EBC pH collected by the two devices in asthma, COPD and cold patients also showed good reproducibility. No differences in pH values were observed between controls (mean pH 8.27; RTube) and patients with COPD (pH 7.97) or asthma (pH 8.20), but lower values were found using both devices in patients with a cold (pH 7.56; RTube, p < 0.01; ECoScreen, p < 0.05).</p> <p>Conclusion</p> <p>We conclude that pH measurements in EBC collected by RTube and ECoScreen are repeatable and reproducible in healthy controls, and are reproducible and comparable in healthy controls, COPD and asthma patients, and subjects with a common cold.</p

    Three-dimensional kinematic motion analysis of a daily activity drinking from a glass: a pilot study

    Get PDF
    BACKGROUND: Development of reliable and objective evaluation methods is required, particularly for natural and goal-oriented upper-extremity tasks. Three-dimensional imaging measurement techniques have turned out to be a powerful tool for a quantitative and qualitative assessment of multijoint movements. The purpose of this study was to develop and test a method of three-dimensional motion analysis for the activity "drinking from a glass" and describe the drinking task with kinematic variables in control subjects. METHODS: A protocol was developed for the drinking activity including the set-up of cameras and positions of the markers and the subject. The drinking task included reaching, forward transport with glass, drinking, back transport and returning the hand to the initial position. An optoelectronic system was used for the three-dimensional kinematic motion capture. Movement times, velocities, joint angles and interjoint coordination for shoulder and elbow were computed and analyzed for twenty control subjects. Test-retest consistency was evaluated for six subjects. RESULTS: The test protocol showed good consistency in test-retest. Phase definitions for the drinking task were defined and verified. Descriptive kinematic variables were obtained for movement times, positions, velocities and joint angles for shoulder and elbow joint. Interjoint coordination between shoulder and elbow joint in reaching phase showed a high correlation. CONCLUSION: This study provides a detailed description of the three-dimensional kinematic analysis of the drinking task. Our approach to investigate and analyze a goal-oriented daily activity has a great clinical potential. Consequently, the next step is to use and test this protocol on persons with impairments and disabilities from upper extremities

    Are Ethnic and Gender Specific Equations Needed to Derive Fat Free Mass from Bioelectrical Impedance in Children of South Asian, Black African-Caribbean and White European Origin? Results of the Assessment of Body Composition in Children Study

    Get PDF
    Background Bioelectrical impedance analysis (BIA) is a potentially valuable method for assessing lean mass and body fat levels in children from different ethnic groups. We examined the need for ethnic- and gender-specific equations for estimating fat free mass (FFM) from BIA in children from different ethnic groups and examined their effects on the assessment of ethnic differences in body fat. Methods Cross-sectional study of children aged 8–10 years in London Primary schools including 325 South Asians, 250 black African-Caribbeans and 289 white Europeans with measurements of height, weight and arm-leg impedance (Z; Bodystat 1500). Total body water was estimated from deuterium dilution and converted to FFM. Multilevel models were used to derive three types of equation {A: FFM = linear combination(height+weight+Z); B: FFM = linear combination(height2/Z); C: FFM = linear combination(height2/Z+weight)}. Results Ethnicity and gender were important predictors of FFM and improved model fit in all equations. The models of best fit were ethnicity and gender specific versions of equation A, followed by equation C; these provided accurate assessments of ethnic differences in FFM and FM. In contrast, the use of generic equations led to underestimation of both the negative South Asian-white European FFM difference and the positive black African-Caribbean-white European FFM difference (by 0.53 kg and by 0.73 kg respectively for equation A). The use of generic equations underestimated the positive South Asian-white European difference in fat mass (FM) and overestimated the positive black African-Caribbean-white European difference in FM (by 4.7% and 10.1% respectively for equation A). Consistent results were observed when the equations were applied to a large external data set. Conclusions Ethnic- and gender-specific equations for predicting FFM from BIA provide better estimates of ethnic differences in FFM and FM in children, while generic equations can misrepresent these ethnic differences

    Insight dimensions and cognitive function in psychosis: a longitudinal study

    Get PDF
    BACKGROUND: It has been reported that lack of insight is significantly associated with cognitive disturbance in schizophrenia. This study examines the longitudinal relationships between insight dimensions and cognitive performance in psychosis. METHODS: Participants were 75 consecutively admitted inpatients with schizophrenia, affective disorder with psychotic symptoms or schizoaffective disorder. Assessments were conducted at two time points during the study: at the time of hospital discharge after an acute psychotic episode and at a follow-up time that occurred more than 6 months after discharge. A multidimensional approach of insight was chosen and three instruments for its assessment were used: the Scale to Assess Unawareness of Mental Disorder (SUMD), three items concerning insight on the Assessment and Documentation in Psychopathology (AMDP) system and the Insight and Treatment Attitudes Questionnaire. The neuropsychological battery included a wide range of tests that assessed global cognitive function, attention, memory, and executive functions. RESULTS: After conducting adequate statistical correction to avoid Type I bias, insight dimensions and cognitive performance were not found to be significantly associated at cross-sectional and longitudinal assessments. In addition, baseline cognitive performance did not explain changes in insight dimensions at follow-up. Similar results were found in the subset of patients with schizophrenia (n = 37). The possibility of a Type II error might have increased due to sample attrition at follow-up. CONCLUSION: These results suggest that lack of insight dimensions and cognitive functioning may be unrelated phenomena in psychosis

    Background Light in Potential Sites for the ANTARES Undersea Neutrino Telescope

    Get PDF
    The ANTARES collaboration has performed a series of {\em in situ} measurements to study the background light for a planned undersea neutrino telescope. Such background can be caused by 40^{40}K decays or by biological activity. We report on measurements at two sites in the Mediterranean Sea at depths of 2400~m and 2700~m, respectively. Three photomultiplier tubes were used to measure single counting rates and coincidence rates for pairs of tubes at various distances. The background rate is seen to consist of three components: a constant rate due to 40^{40}K decays, a continuum rate that varies on a time scale of several hours simultaneously over distances up to at least 40~m, and random bursts a few seconds long that are only correlated in time over distances of the order of a meter. A trigger requiring coincidences between nearby photomultiplier tubes should reduce the trigger rate for a neutrino telescope to a manageable level with only a small loss in efficiency.Comment: 18 pages, 8 figures, accepted for publication in Astroparticle Physic

    The cost of large numbers of hypothesis tests on power, effect size and sample size

    Get PDF
    Advances in high-throughput biology and computer science are driving an exponential increase in the number of hypothesis tests in genomics and other scientific disciplines. Studies using current genotyping platforms frequently include a million or more tests. In addition to the monetary cost, this increase imposes a statistical cost owing to the multiple testing corrections needed to avoid large numbers of false-positive results. To safeguard against the resulting loss of power, some have suggested sample sizes on the order of tens of thousands that can be impractical for many diseases or may lower the quality of phenotypic measurements. This study examines the relationship between the number of tests on the one hand and power, detectable effect size or required sample size on the other. We show that once the number of tests is large, power can be maintained at a constant level, with comparatively small increases in the effect size or sample size. For example at the 0.05 significance level, a 13% increase in sample size is needed to maintain 80% power for ten million tests compared with one million tests, whereas a 70% increase in sample size is needed for 10 tests compared with a single test. Relative costs are less when measured by increases in the detectable effect size. We provide an interactive Excel calculator to compute power, effect size or sample size when comparing study designs or genome platforms involving different numbers of hypothesis tests. The results are reassuring in an era of extreme multiple testing
    • …
    corecore