610 research outputs found

    The Gerasimov-Drell-Hearn sum rule and the infinite-momentum limit

    Full text link
    We study the current-algebra approach to the Gerasimov-Drell-Hearn sum rule, paying particular attention to the infinite-momentum limit. Employing the order-alpha^2 Weinberg-Salam model of weak interactions as a testing ground, we find that the legitimacy of the infinite-momentum limit is intimately connected with the validity of the naive equal-times algebra of electric charge densities. Our results considerably reduce the reliability of a recently proposed modification of the Gerasimov-Drell-Hearn sum rule, originating from an anomalous charge-density algebra.Comment: 12 pages; 6 figures; LaTeX; submitted to Z.Phys.

    Caveolin-3 differentially orchestrates cholinergic and serotonergic constriction of murine airways

    Get PDF
    The mechanisms of controlling airway smooth muscle (ASM) tone are of utmost clinical importance as inappropriate constriction is a hallmark in asthma and chronic obstructive pulmonary disease. Receptors for acetylcholine and serotonin, two relevant mediators in this context, appear to be incorporated in specialized, cholesterol-rich domains of the plasma membrane, termed caveolae due to their invaginated shape. The structural protein caveolin-1 partly accounts for anchoring of these receptors. We here determined the role of the other major caveolar protein, caveolin-3 (cav-3), in orchestrating cholinergic and serotonergic ASM responses, utilizing newly generated cav-3 deficient mice. Cav-3 deficiency fully abrogated serotonin-induced constriction of extrapulmonary airways in organ baths while leaving intrapulmonary airways unaffected, as assessed in precision cut lung slices. The selective expression of cav-3 in tracheal, but not intrapulmonary bronchial epithelial cells, revealed by immunohistochemistry, might explain the differential effects of cav-3 deficiency on serotonergic ASM constriction. The cholinergic response of extrapulmonary airways was not altered, whereas a considerable increase was observed in cav-3â -/- intrapulmonary bronchi. Thus, cav-3 differentially organizes serotonergic and cholinergic signaling in ASM through mechanisms that are specific for airways of certain caliber and anatomical position. This may allow for selective and site-specific intervention in hyperreactive states

    Dispersion Effects in Nucleon Polarisabilities

    Get PDF
    We present a formalism to extract the dynamical nucleon polarisabilities defined via a multipole expansion of the structure amplitudes in nucleon Compton scattering. In contradistinction to the static polarisabilities, dynamical polarisabilities gauge the response of the internal degrees of freedom of a composed object to an external, real photon field of arbitrary energy. Being energy dependent, they therefore contain additional information about dispersive effects induced by internal relaxation mechanisms, baryonic resonances and meson production thresholds of the nucleon. We give explicit formulae to extract the dynamical electric and magnetic dipole as well as quadrupole polarisabilities from low energy nucleon Compton scattering up to the one pion production threshold and discuss the connection to the definition of static nucleon polarisabilities. As a concrete example, we examine the results of leading order Heavy Baryon Chiral Perturbation Theory for the four leading spin independent iso-scalar polarisabilities of the nucleon. Finally, we consider the possible r{\^o}le of energy dependent effects in low energy extractions of the iso-scalar dipole polarisabilities from Compton scattering on the deuteron.Comment: 17 pages LaTeX2e with 2 figures, using includegraphicx (5 .eps files). Minor corrections, references updated. Contents identical to version to appear in Phys. Rev. C 65, spelling differen

    Overview of the Nordic Seas CARINA data and salinity measurements

    Get PDF
    Water column data of carbon and carbon relevant hydrographic and hydrochemical parameters from 188 previously non-publicly available cruises in the Arctic, Atlantic, and Southern Ocean have been retrieved and merged into a new database: CARINA (CARbon IN the Atlantic). The data have been subject to rigorous quality control (QC) in order to ensure highest possible quality and consistency. The data for most of the parameters included were examined in order to quantify systematic biases in the reported values, i.e. secondary quality control. Significant biases have been corrected for in the data products, i.e. the three merged files with measured, calculated and interpolated values for each of the three CARINA regions; the Arctic Mediterranean Seas (AMS), the Atlantic (ATL) and the Southern Ocean (SO). With the adjustments the CARINA database is consistent both internally as well as with GLODAP (Key et al., 2004) and is suitable for accurate assessments of, for example, oceanic carbon inventories and uptake rates and for model validation. The Arctic Mediterranean Seas include the Arctic Ocean and the Nordic Seas, and the quality control was carried out separately in these two areas. This contribution provides an overview of the CARINA data from the Nordic Seas and summarises the findings of the QC of the salinity data. One cruise had salinity data that were of questionable quality, and these have been removed from the data product. An evaluation of the consistency of the quality controlled salinity data suggests that they are consistent to at least ±0.005

    Effective decrease of photoelectric emission threshold from gold plated surfaces

    Full text link
    Many applications require charge neutralisation of isolated test bodies and this has been successfully done using photoelectric emission from surfaces which are electrically benign(gold) or superconducting (niobium). Gold surfaces nominally have a high work function (5.1\sim 5.1\,eV)which should require deep UV photons for photoemission. In practice it has been found that it can be achieved with somewhat lower energy photons with indicative work functions of (4.14.3 4.1-4.3\,eV). A detailed working understanding of the process is lacking and this work reports on a study of the photoelectric emission properties of 4.6x4.6 cm^2 gold plated surfaces, representative of those used in typical satellite applications with a film thickness of 800 nm, and measured surface roughnesses between 7 and 340 nm. Various UV sources with photon energies from 4.8 to 6.2 eV and power outputs from 1 nW to 1000 nW, illuminated a ~0.3 cm^2 of the central surface region at angles of incidence from 0 to 60 degrees. Final extrinsic quantum yields in the range 10 ppm to 44 ppm were reliably obtained during 8 campaigns, covering a ~3 year period, but with intermediate long-term variations lasting several weeks and, in some cases, bake-out procedures at up to 200 C. Experimental results were obtained in a vacuum system with a baseline pressure of ~10^{-7} mbar at room temperature. A working model, designed to allow accurate simulation of any experimental configuration, is proposed.Comment: 35 pages, 12 figure

    Automatic radiographic quantification of hand osteoarthritis; accuracy and sensitivity to change in joint space width in a phantom and cadaver study

    Get PDF
    This is the final version of the article. Available from Springer Verlag via the DOI in this record.OBJECTIVE: To validate a newly developed quantification method that automatically detects and quantifies the joint space width (JSW) in hand radiographs. Repeatability, accuracy and sensitivity to changes in JSW were determined. The influence of joint location and joint shape on the measurements was tested. METHODS: A mechanical micrometer set-up was developed to define and adjust the true JSW in an acrylic phantom joint and in human cadaver-derived phalangeal joints. Radiographic measurements of the JSW were compared to the true JSW. Repeatability, systematic error (accuracy) and sensitivity (defined as the smallest detectable difference (SDD)) were determined. The influence of joint position on the JSW measurement was assessed by varying the location of the acrylic phantom on the X-ray detector with respect to the X-ray beam and the influence of joint shape was determined by using morphologically different human cadaver joints. RESULTS: The mean systematic error was 0.052 mm in the phantom joint and 0.210 mm in the cadaver experiment. In the phantom experiments, the repeatability was high (SDD = 0.028 mm), but differed slightly between joint locations (p = 0.046), and a change in JSW of 0.037 mm could be detected. Dependent of the joint shape in the cadaver hand, a change in JSW between 0.018 and 0.047 mm could be detected. CONCLUSIONS: The automatic quantification method is sensitive to small changes in JSW. Considering the published data of JSW decline in the normal and osteoarthritic population, the first signs of OA progression with this method can be detected within 1 or 2 years.This work was funded by the Dutch Arthritis Association (Reumafonds). The study sponsor had no involvement in study design, data collection, data analysis, or interpretation of the results

    Nonlocal electrostatics in heterogeneous suspensions using a point-dipole model

    Full text link
    This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder

    Compton scattering on the nucleon at intermediate energies and polarizabilities in a microscopic model

    Get PDF
    A microscopic calculation of Compton scattering on the nucleon is presented which encompasses the lowest energies -- yielding nucleon polarizabilities -- and extends to energies of the order of 600 MeV. We have used the covariant "Dressed K-Matrix Model" obeying the symmetry properties which are appropriate in the different energy regimes. In particular, crossing symmetry, gauge invariance and unitarity are satisfied. The extent of violation of analyticity (causality) is used as an expansion parameter.Comment: 35 pages, 15 figures, using REVTeX. Modified version to be published in Phys. Rev. C, more extensive comparison with data for Compton scattering, all results unchange

    The Self-Administered Witness Interview Tool (SAW-IT): Enhancing witness recall of workplace incidents

    Get PDF
    Given the often crucial role of witness evidence in Occupational Health and Safety investigation, statements should be obtained as soon as possible after an incident using best practice methods. The present research systematically tested the efficacy of a novel Self-Administered Witness Interview Tool (SAW-IT); an adapted version of the Self-Administered Interview (SAI©) designed to elicit comprehensive information from witnesses to industrial events. The present study also examined whether completing the SAW-IT mitigated the effect of schematic processing on witness recall. Results indicate that the SAW-IT elicited significantly more correct details, as well as more precise information than a traditional incident report form. Neither the traditional report from, nor the SAW-IT mitigated against biasing effects of contextual information about a worker’s safety history, confirming that witnesses should be shielded from extraneous post-event information prior to reporting. Importantly, these results demonstrate that the SAW-IT can enhance the quality of witness reports
    corecore