2,518 research outputs found

    MS Prevalence and Patients' Characteristics in the District of Braga, Portugal

    Get PDF
    Multiple Sclerosis (MS) is a chronic autoimmune disease of the Central Nervous System causing inflammation and neurodegeneration. There are only 3 epidemiological studies in Portugal, 2 in the Centre and 1 in the North, and there is the need to further study MS epidemiology in this country. The objective of this work is to contribute to the MS epidemiological knowledge in Portugal, describing the patients' epidemiological, demographic, and clinical characteristics in the Braga district of Portugal. This is a cross-sectional study of 345 patients followed in two hospitals of Braga district. These hospitals cover a resident population of 866,012 inhabitants. The data was collected from the clinical records, and 31/12/2009 was established as the prevalence day. For all MS patients, demographic characteristics and clinical outcomes are reported. We have found an incidence of 2.74/100,000 and a prevalence of 39.82/100,000 inhabitants. Most patients have an EDSS of 3 or lower and a mean age of 42 years. The diagnosis was done at mean age of 35, with RRMS being the disease type in more than 80% of patients. In this cohort, we found a female : male ratio of 1.79. More than 50% of patients are treated with Interferon β-1b IM or IFNβ-1a SC 22 μg

    Use of electrospinning to develop antimicrobial biodegradable multilayer systems: encapsulation of cinnamaldehyde and their physicochemical characterization

    Get PDF
    In this work, three active bio-based multilayer structures, using a polyhydroxybutyrate-co-valerate film with a valerate content of 8 % (PHBV8) as support, were developed. To this end, a zein interlayer with or without cinnamaldehyde (CNMA) was directly electrospun onto one side of the PHBV8 film and the following systems were developed: (1) without an outer layer; (2) using a PHBV8 film as outer layer; and (3) using an alginate-based film as outer layer. These multilayer structures were characterized in terms of water vapour and oxygen permeabilities, transparency, intermolecular arrangement and thermal properties. The antimicrobial activity of the active bio-based multilayer systems and the release of CNMA in a food simulant were also evaluated. Results showed that the presence of different outer layers reduced the transport properties and transparency of the multilayer films. The active bio-based multilayer systems showed antibacterial activity against Listeria monocytogenes being the multilayer structure prepared with CNMA and PHBV outer layers (PHBV + zein/CNMA + PHBV) the one that showed the greater antibacterial activity. The release of CNMA depended on the multilayer structures, where both Fick's and Case II transport-polymer relaxation explained the release of CNMA from the multilayer systems.Acknowledgments: Miguel A. Cerqueira (SFRH/BPD/72753/2010) andAnaI.Bourbon(SFRH/BD/73178/2010)arerecipientofafellowship from the Fundação para a Ciência e Tecnologia (FCT, POPH-QREN and FSE Portugal). J.L. Castro-Mayorga is supported by the Administrative Department of Science, Technology and Innovation (Colciencias) of Colombian Government. M. J. Fabra is a recipient of a Ramon y Cajal contract (RyC-2014-158) from the Spanish Ministry of Economy and Competitiveness. This study was supported by the Portuguese Foundation for Science and Technology (FCT) under the scope of the strategic funding of UID/BIO/04469/2013 unit and COMPETE 2020 (POCI-01-0145-FEDER-006684) and of the Project RECI/BBB-EBI/ 0179/2012 (FCOMP-01-0124-FEDER-027462). The support of EU Cost Action MP1206 is gratefully acknowledged

    Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>T1 mapping allows direct <it>in-vivo </it>quantitation of microscopic changes in the myocardium, providing new diagnostic insights into cardiac disease. Existing methods require long breath holds that are demanding for many cardiac patients. In this work we propose and validate a novel, clinically applicable, pulse sequence for myocardial T1-mapping that is compatible with typical limits for end-expiration breath-holding in patients.</p> <p>Materials and methods</p> <p>The Shortened MOdified Look-Locker Inversion recovery (ShMOLLI) method uses sequential inversion recovery measurements within a single short breath-hold. Full recovery of the longitudinal magnetisation between sequential inversion pulses is not achieved, but conditional interpretation of samples for reconstruction of T1-maps is used to yield accurate measurements, and this algorithm is implemented directly on the scanner. We performed computer simulations for 100 ms<T1 < 2.7 s and heart rates 40-100 bpm followed by phantom validation at 1.5T and 3T. <it>In-vivo </it>myocardial T1-mapping using this method and the previous gold-standard (MOLLI) was performed in 10 healthy volunteers at 1.5T and 3T, 4 volunteers with contrast injection at 1.5T, and 4 patients with recent myocardial infarction (MI) at 3T.</p> <p>Results</p> <p>We found good agreement between the average ShMOLLI and MOLLI estimates for T1 < 1200 ms. In contrast to the original method, ShMOLLI showed no dependence on heart rates for long T1 values, with estimates characterized by a constant 4% underestimation for T1 = 800-2700 ms. <it>In-vivo</it>, ShMOLLI measurements required 9.0 ± 1.1 s (MOLLI = 17.6 ± 2.9 s). Average healthy myocardial T1 s by ShMOLLI at 1.5T were 966 ± 48 ms (mean ± SD) and 1166 ± 60 ms at 3T. In MI patients, the T1 in unaffected myocardium (1216 ± 42 ms) was similar to controls at 3T. Ischemically injured myocardium showed increased T1 = 1432 ± 33 ms (p < 0.001). The difference between MI and remote myocardium was estimated 15% larger by ShMOLLI than MOLLI (p < 0.04) which suffers from heart rate dependencies for long T1. The <it>in-vivo </it>variability within ShMOLLI T1-maps was only 14% (1.5T) or 18% (3T) higher than the MOLLI maps, but the MOLLI acquisitions were twice longer than ShMOLLI acquisitions.</p> <p>Conclusion</p> <p>ShMOLLI is an efficient method that generates immediate, high-resolution myocardial T1-maps in a short breath-hold with high precision. This technique provides a valuable clinically applicable tool for myocardial tissue characterisation.</p

    Ultrasound Imaging Versus Morphopathology in Cardiovascular Diseases: The Heart Failure

    Get PDF
    This review article summarizes the results of histopathological studies to assess heart failure in humans. Different histopathological features underlying the clinical manifestations of heart failure are reviewed. In addition, the present role of echocardiographic techniques in assessing the failing heart is briefly summarized

    Baseline mitral regurgitation predicts outcome in patients referred for dobutamine stress echocardiography

    Get PDF
    Purpose: A number of parameters recorded during dobutamine stress echocardiography (DSE) are associated with worse outcome. However, the relative importance of baseline mitral regurgitation (MR) is unknown. The aim of this study was to assess the prevalence and associated implications of functional MR with long-term mortality in a large cohort of patients referred for DSE. Methods: 6745 patients (mean age 64.9±12.2 years) were studied. Demographic, baseline and peak DSE data were collected. All-cause mortality was retrospectively analyzed. DSE was successfully completed in all patients with no adverse outcomes. Results: MR was present in 1019 (15.1%) patients. During a mean follow up of 5.1±1.8 years, 1642 (24.3%) patients died and MR was significantly associated with increased all-cause mortality (p<0.001). With Kaplan-Meier analysis, survival was significantly worse for patients with moderate and severe MR (p<0.001). With multivariate Cox regression analysis, moderate and severe MR (HR 2.78; 95% CI 2.17 - 3.57; and HR 3.62; 95% CI 2.89 - 4.53, respectively) were independently associated with all-cause mortality. The addition of MR to C statistic models significantly improved discrimination. Conclusions: MR is associated with all-cause mortality and adds incremental prognostic information among patients referred for DSE. The presence of MR should be taken into account when evaluating the prognostic significance of DSE results

    Differential impact of chronic stress along the hippocampal dorsal–ventral axis

    Get PDF
    First published online 06 February 2014Stress impacts differently in distinct brain regions. However, so far few studies have focused on the differential responses triggered by stressful stimuli on the intrinsic functional heterogeneity of the hippocampal axis. In this study, we assessed the functional and structural alterations caused by exposure to a chronic unpredictable stress (CUS) paradigm on the dorsal-ventral axis of the hippocampus. The morphological analysis demonstrated that CUS had opposite outcomes in the structure of the dorsal (DH) and ventral hippocampus (VH): whereas in the DH, stress triggered a volumetric reduction as a result of atrophy of CA3 and CA1 apical dendrites, in the VH there was an increase in hippocampal volume concurrent with the increase of CA3 apical dendrites. In parallel, electrophysiological data revealed that stress led to a decrease in VH LTD. In summary, the present work showed that stress impacts differently on the structure and function of the DH and VH which contributes to better understand the overall spectrum of the central effects of stress.Pinto V and Mota C were supported by Fundacao para a Ciencia e Tecnologia (FCT) grants (SFRH/BPD/69132/2010; SFRH/BD/81881/2011, respectively). This work was supported by an FCT grant (PTDC/SAU-NSC/120590/2010). The authors declare no competing financial interests

    Dobutamine stress cardiovascular magnetic resonance at 3 Tesla

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>The assessment of inducible wall motion abnormalities during high-dose dobutamine-stress cardiovascular magnetic resonance (DCMR) is well established for the identification of myocardial ischemia at 1.5 Tesla. Its feasibility at higher field strengths has not been reported. The present study was performed to prospectively determine the feasibility and diagnostic accuracy of DCMR at 3 Tesla for depicting hemodynamically significant coronary artery stenosis (≥ 50% diameter stenosis) in patients with suspected or known coronary artery disease (CAD).</p> <p>Materials and methods</p> <p>Thirty consecutive patients (6 women) (66 ± 9.3 years) were scheduled for DCMR between January and May 2007 for detection of coronary artery disease. Patients were examined with a Philips Achieva 3 Tesla system (Philips Healthcare, Best, The Netherlands), using a spoiled gradient echo cine sequence. Technical parameters were: spatial resolution 2 × 2 × 8 mm<sup>3</sup>, 30 heart phases, spoiled gradient echo TR/TE: 4.5/2.6 msec, flip angle 15°. Images were acquired at rest and stress in accordance with a standardized high-dose dobutamine-atropine protocol during short breath-holds in three short and three long-axis views. Dobutamine was administered using a standard protocol (10 μg increments every 3 minutes up to 40 μg dobutamine/kg body weight/minute plus atropine if required to reach target heart rate). The study protocol included administration of 0.1 mmol/kg/body weight Gd-DTPA before the cine images at rest were acquired to improve the image quality. The examination was terminated if new or worsening wall-motion abnormalities or chest pain occurred or when > 85% of age-predicted maximum heart rate was reached. Myocardial ischemia was defined as new onset of wall-motion abnormality in at least one segment. In addition, late gadolinium enhancement (LGE) was performed. Images were evaluated by two blinded readers. Diagnostic accuracy was determined with coronary angiography as the reference standard. Image quality and wall-motion at rest and maximum stress level were evaluated using a four-point scale.</p> <p>Results</p> <p>In 27 patients DCMR was performed successfully, no patient had to be excluded due to insufficient image quality. Twenty-two patients were examined by coronary angiography, which depicted significant stenosis in 68.2% of the patients. Patient-based sensitivity and specificity were 80.0% and 85.7% respectively and accuracy was 81.8%. Interobserver variability for assessment of wall motion abnormalities was 88% (κ = 0.760; p < 0.0001). Negative and positive predictive values were 66.7% and 92.3%, respectively. No significant differences in average image quality at rest versus stress for short or long-axis cine images were found.</p> <p>Conclusion</p> <p>High-dose DCMR at 3T is feasible and an accurate method to depict significant coronary artery stenosis in patients with suspected or known CAD.</p

    Vascular relaxation of canine visceral arteries after ischemia by means of supraceliac aortic cross-clamping followed by reperfusion

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The supraceliac aortic cross-clamping can be an option to save patients with hipovolemic shock due to abdominal trauma. However, this maneuver is associated with ischemia/reperfusion (I/R) injury strongly related to oxidative stress and reduction of nitric oxide bioavailability. Moreover, several studies demonstrated impairment in relaxation after I/R, but the time course of I/R necessary to induce vascular dysfunction is still controversial. We investigated whether 60 minutes of ischemia followed by 30 minutes of reperfusion do not change the relaxation of visceral arteries nor the plasma and renal levels of malondialdehyde (MDA) and nitrite plus nitrate (NOx).</p> <p>Methods</p> <p>Male mongrel dogs (n = 27) were randomly allocated in one of the three groups: sham (no clamping, n = 9), ischemia (supraceliac aortic cross-clamping for 60 minutes, n = 9), and I/R (60 minutes of ischemia followed by reperfusion for 30 minutes, n = 9). Relaxation of visceral arteries (celiac trunk, renal and superior mesenteric arteries) was studied in organ chambers. MDA and NOx concentrations were determined using a commercially available kit and an ozone-based chemiluminescence assay, respectively.</p> <p>Results</p> <p>Both acetylcholine and calcium ionophore caused relaxation in endothelium-intact rings and no statistical differences were observed among the three groups. Sodium nitroprusside promoted relaxation in endothelium-denuded rings, and there were no inter-group statistical differences. Both plasma and renal concentrations of MDA and NOx showed no significant difference among the groups.</p> <p>Conclusion</p> <p>Supraceliac aortic cross-clamping for 60 minutes alone and followed by 30 minutes of reperfusion did not impair relaxation of canine visceral arteries nor evoke biochemical alterations in plasma or renal tissue.</p

    Design and validation of Segment - freely available software for cardiovascular image analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Commercially available software for cardiovascular image analysis often has limited functionality and frequently lacks the careful validation that is required for clinical studies. We have already implemented a cardiovascular image analysis software package and released it as freeware for the research community. However, it was distributed as a stand-alone application and other researchers could not extend it by writing their own custom image analysis algorithms. We believe that the work required to make a clinically applicable prototype can be reduced by making the software extensible, so that researchers can develop their own modules or improvements. Such an initiative might then serve as a bridge between image analysis research and cardiovascular research. The aim of this article is therefore to present the design and validation of a cardiovascular image analysis software package (Segment) and to announce its release in a source code format.</p> <p>Results</p> <p>Segment can be used for image analysis in magnetic resonance imaging (MRI), computed tomography (CT), single photon emission computed tomography (SPECT) and positron emission tomography (PET). Some of its main features include loading of DICOM images from all major scanner vendors, simultaneous display of multiple image stacks and plane intersections, automated segmentation of the left ventricle, quantification of MRI flow, tools for manual and general object segmentation, quantitative regional wall motion analysis, myocardial viability analysis and image fusion tools. Here we present an overview of the validation results and validation procedures for the functionality of the software. We describe a technique to ensure continued accuracy and validity of the software by implementing and using a test script that tests the functionality of the software and validates the output. The software has been made freely available for research purposes in a source code format on the project home page <url>http://segment.heiberg.se</url>.</p> <p>Conclusions</p> <p>Segment is a well-validated comprehensive software package for cardiovascular image analysis. It is freely available for research purposes provided that relevant original research publications related to the software are cited.</p
    corecore