58 research outputs found

    Monitoring and correcting spatio-temporal variations of the MR scanner's static magnetic field

    Get PDF
    The homogeneity and stability of the static magnetic field are of paramount importance to the accuracy of MR procedures that are sensitive to phase errors and magnetic field inhomogeneity. It is shown that intense gradient utilization in clinical horizontal-bore superconducting MR scanners of three different vendors results in main magnetic fields that vary on a long time scale both spatially and temporally by amounts of order 0.8-2.5 ppm. The observed spatial changes have linear and quadratic variations that are strongest along the z direction. It is shown that the effect of such variations is of sufficient magnitude to completely obfuscate thermal phase shifts measured by proton-resonance frequency-shift MR thermometry and certainly affect accuracy. In addition, field variations cause signal loss and line-broadening in MR spectroscopy, as exemplified by a fourfold line-broadening of metabolites over the course of a 45 min human brain study. The field variations are consistent with resistive heating of the magnet structures. It is concluded that correction strategies are required to compensate for these spatial and temporal field drifts for phase-sensitive MR protocols. It is demonstrated that serial field mapping and phased difference imaging correction protocols can substantially compensate for the drift effects observed in the MR thermometry and spectroscopy experiments. © 2006 ESMRMB

    Cross-National Logo Evaluation Analysis: An Individual Level Approach

    Get PDF
    The universality of design perception and response is tested using data collected from ten countries: Argentina, Australia, China, Germany, Great Britain, India, the Netherlands, Russia, Singapore, and the United States. A Bayesian, finite-mixture, structural-equation model is developed that identifies latent logo clusters while accounting for heterogeneity in evaluations. The concomitant variable approach allows cluster probabilities to be country specific. Rather than a priori defined clusters, our procedure provides a posteriori cross-national logo clusters based on consumer response similarity. To compare the a posteriori cross-national logo clusters, our approach is integrated with Steenkamp and Baumgartner’s (1998) measurement invariance methodology. Our model reduces the ten countries to three cross-national clusters that respond differently to logo design dimensions: the West, Asia, and Russia. The dimensions underlying design are found to be similar across countries, suggesting that elaborateness, naturalness, and harmony are universal design dimensions. Responses (affect, shared meaning, subjective familiarity, and true and false recognition) to logo design dimensions (elaborateness, naturalness, and harmony) and elements (repetition, proportion, and parallelism) are also relatively consistent, although we find minor differences across clusters. Our results suggest that managers can implement a global logo strategy, but they also can optimize logos for specific countries if desired.adaptation;standardization;Bayesian;international marketing;design;Gibbs sampling;concomitant variable;logos;mixture models;structural equation models

    Interventional MRI: Tapering improves the distal sensitivity of the loopless antenna

    Get PDF
    The "loopless antenna" is an interventional MRI detector consisting of a tuned coaxial cable and an extended inner conductor or "whip". A limitation is the poor sensitivity afforded at, and immediately proximal to, its distal end, which is exacerbated by the extended whip length when the whip is uniformly insulated. It is shown here that tapered insulation dramatically improves the distal sensitivity of the loopless antenna by pushing the current sensitivity toward the tip. The absolute signal-to-noise ratio is numerically computed by the electromagnetic method-of-moments for three resonant 3-T antennae with no insulation, uniform insulation, and with linearly tapered insulation. The analysis shows that tapered insulation provides an ∼400% increase in signal-to-noise ratio in trans-axial planes 1 cm from the tip and a 16-fold increase in the sensitive area as compared to an equivalent, uniformly insulated antenna. These findings are directly confirmed by phantom experiments and by MRI of an aorta specimen. The results demonstrate that numerical electromagnetic signal-tonoise ratio analysis can accurately predict the loopless detector's signal-to-noise ratio and play a central role in optimizing its design. The manifold improvement in distal signal-to-noise ratio afforded by redistributing the insulation should improve the loopless antenna's utility for interventional MRI. © 2010 Wiley-Liss, Inc

    Absolute temperature monitoring using RF radiometry in the MRI scanner

    Get PDF
    Temperature detection using microwave radiometry has proven value for noninvasively measuring the absolute temperature of tissues inside the body. However, current clinical radiometers operate in the gigahertz range, which limits their depth of penetration. We have designed and built a noninvasive radiometer which operates at radio frequencies (64 MHz) with ∼100-kHz bandwidth, using an external RF loop coil as a thermal detector. The core of the radiometer is an accurate impedance measurement and automatic matching circuit of 0.05 Ω accuracy to compensate for any load variations. The radiometer permits temperature measurements with accuracy of ±0.1°K, over a tested physiological range of 28°C-40 °C in saline phantoms whose electric properties match those of tissue. Because 1.5 T magnetic resonance imaging (MRI) scanners also operate at 64 MHz, we demonstrate the feasibility of integrating our radiometer with an MRI scanner to monitor RF power deposition and temperature dosimetry, obtaining coarse, spatially resolved, absolute thermal maps in the physiological range. We conclude that RF radiometry offers promise as a direct, noninvasive method of monitoring tissue heating during MRI studies and thereby providing an independent means of verifying patient-safe operation. Other potential applications include titration of hyper- and hypo-therapies. © 2006 IEEE

    Cross-National Logo Evaluation Analysis: An Individual Level Approach

    Get PDF
    The universality of design perception and response is tested using data collected from ten countries: Argentina, Australia, China, Germany, Great Britain, India, the Netherlands, Russia, Singapore, and the United States. A Bayesian, finite-mixture, structural-equation model is developed that identifies latent logo clusters while accounting for heterogeneity in evaluations. The concomitant v

    Mutations of the BRAF gene in human cancer

    Get PDF
    Cancers arise owing to the accumulation of mutations in critical genes that alter normal programmes of cell proliferation, differentiation and death. As the first stage of a systematic genome-wide screen for these genes, we have prioritized for analysis signalling pathways in which at least one gene is mutated in human cancer. The RAS RAF MEK ERK MAP kinase pathway mediates cellular responses to growth signals. RAS is mutated to an oncogenic form in about 15% of human cancer. The three RAF genes code for cytoplasmic serine/threonine kinases that are regulated by binding RAS. Here we report BRAF somatic missense mutations in 66% of malignant melanomas and at lower frequency in a wide range of human cancers. All mutations are within the kinase domain, with a single substitution (V599E) accounting for 80%. Mutated BRAF proteins have elevated kinase activity and are transforming in NIH3T3 cells. Furthermore, RAS function is not required for the growth of cancer cell lines with the V599E mutation. As BRAF is a serine/threonine kinase that is commonly activated by somatic point mutation in human cancer, it may provide new therapeutic opportunities in malignant melanoma

    Current state of quality of life and patient-reported outcomes research

    Get PDF
    The 5th EORTC Quality of Life in Cancer Clinical Trials Conference presented the current state of quality of life and other patient-reported outcomes (PROs) research from the perspectives of researchers, regulators, industry representatives, patients and patient advocates and health care professionals. A major theme was the assessment of the burden of cancer treatments, and this was discussed in terms of regulatory challenges in using PRO assessments in clinical trials, patients' experiences in cancer clinical trials, innovative methods and standardisation in cancer research, innovative methods across the disease sites or populations and cancer survivorship. Conferees demonstrated that PROs are becoming more accepted and major efforts are ongoing internationally to standardise PROs measurement, analysis and reporting in trials. Regulators are keen to collaborate with all stakeholders to ensure that the right questions are asked and the right answers are communicated. Improved technology and increased flexibility of measurement instruments are making PROs data more robust. Patients are being encouraged to be patient partners. International collaborations are essential, because this work cannot be accomplished on a national level

    RF radiometery sensor sensitivity and detection profile

    No full text
    Temperature sensing using microwave radiometry has proven value for non-invasively measuring the absolute temperature of tissues inside the human body. However, current clinical radiometers operate in GHz or infrared frequency ranges; this limits their depth of penetration since the human body is not "transparent" at these frequencies. To address this problem, we have previously designed and built an advanced, near-field radiometer operating at VHF frequencies (64MHz) with a ∼100 KHz bandwidth. The radiometer has performed accurate temperature measurements to within ±0.1°C, over a tested physiological range of 28-40°C in saline phantoms whose electric properties match those of human tissue. In this work we analyze radiofrequency (RF) coil designs suitable for RF Radiometry. We investigate the coil profile sensitivity to look where temperature information is coming from and the depth of penetration associated with the receiver used. We also look into the virtues of using multi-turn coils versus single loop coils. We conclude that by using multi-turn coils the received noise signal is more sensitive to sample noise and temperature can be estimated more accurately especially with the use of smaller receivers. © 2008 IEEE
    corecore