300 research outputs found
Fractionated Stereotactic Radiation Therapy for Pituitary Adenomas: An alternative escalating protocol of hypofractionated stereotactic radiotherapy delivering 35Gy in 5 fractions
PURPOSE: Evaluate efficacy and toxicity of hypofractionated stereotactic radiotherapy (HSRT) for patients treated for pituitary adenoma (PA) with an alternative HSRT escalating protocol delivering 35Gy in 5 fractions. MATERIAL AND METHODS: From June 2007 to March 2017, 29 patients with pituitary adenoma were treated in Antoine Lacassagne Cancer Centre with an alternative HSRT protocol. Prescribed dose was 35Gy in 5 fractions of 7Gy. Radiographic responses were assessed by annual MRI. Hormone blood samples were evaluated each year after HSRT. RESULTS: A total of 29 patients aged between 23 and 86 years (median 54 years) were included. Twelve patients received HSRT for recurrent cases and 12 received postoperative adjuvant HSRT, 5 patients did not have surgery. After a median follow-up period of 47 months local control rate was 96%. One patient presented an out-field tumor regrowth 73 months after HSRT. The majority of PA were endocrine-active (18 patients, 62%). After HSRT, 8 patients (44%) presented complete response on initial secretion, 4 patients (23%) presented partial response on initial secretion. Four patients (14%) presented grade 2 or more acute radiation toxicities. One grade 4 visual disorder was observed for one patient. CONCLUSIONS: HSRT delivering 35Gy in 5 fractions represents a feasible treatment and shows promising results to reduce hormonal overproduction and to improve local control in PA
Implantable cardioverter defibrillator therapy for primary prevention of sudden cardiac death in the real world: Main findings from the French multicentre DAI-PP programme (pilot phase)
This review summarizes the main findings of the French multicentre DAI-PP pilot programme, and discusses the related clinical and research perspectives. This project included retrospectively (2002–2012 period) more than 5000 subjects with structural heart disease who received an implantable cardioverter defibrillator (ICD) for primary prevention of sudden cardiac death, and were followed for a mean period of 3 years. The pilot phase of the DAI-PP programme has provided valuable information on several practical and clinically relevant aspects of primary prevention ICD implantation in the real-world population, which are summarized in this review. This pilot has led to a prospective evaluation that started in May 2018, assessing ICD therapy in primary and secondary prevention in patients with structural and electrical heart diseases, with remote monitoring follow-up using a dedicated platform. This should further enhance our understanding of sudden cardiac death, to eventually optimize the field of preventative actions
Botulinum toxin in gastric submucosa reduces stimulated HCl production in rats
BACKGROUND: Botulinum toxin blocks acetylcholine release from nerve endings and acts as a long term, reversible inhibitor of muscle contraction as well as of salivary, sweat gland, adrenal and prostatic secretions. The aim of the present study is to investigate whether gastric submucosal injection of botulinum toxin type A reduces stimulated gastric production of HCl. METHODS: Sixty-four rats were randomized in two groups and laparotomized. One group was treated with botulinum toxin-A 10 U by multiple submucosal gastric injections, while the second group was injected with saline. Two weeks later, acid secretion was stimulated by pyloric ligation and acid output was measured. Body weight, food and water intake were also recorded daily. RESULTS: HCl production after pyloric ligation was found to be significantly lower in botulinum toxin-treated rats (657 ± 90.25 micromol HCl vs. 1247 ± 152. P = 0.0017). Botulinum toxin-treated rats also showed significantly lower food intake and weight gain. CONCLUSIONS: Botulinum toxin type A reduces stimulated gastric acidity. This is likely due either to inhibition of the cholinergic stimulation of gastric parietal cells, or to an action on the myenteric nervous plexuses. Reduction of growth and food intake may reflect both impaired digestion and decreased gastric motility
Device complications with addition of defibrillation to cardiac resynchronisation therapy for primary prevention
Objective: In patients indicated for cardiac resynchronisation therapy (CRT), the choice between a CRT-pacemaker (CRT-P) versus defibrillator (CRT-D) remains controversial and indications in this setting have not been well delineated. Apart from inappropriate therapies, which are inherent to the presence of a defibrillator, whether adding defibrillator to CRT in the primary prevention setting impacts risk of other acute and late device-related complications has not been well studied and may bear relevance for device selection. //
Methods: Observational multicentre European cohort study of 3008 consecutive patients with ischaemic or non-ischaemic dilated cardiomyopathy and no history of sustained ventricular arrhythmias, undergoing CRT implantation with (CRT-D, n=1785) or without (CRT-P, n=1223) defibrillator. Using propensity score and competing risk analyses, we assessed the risk of significant device-related complications requiring surgical reintervention. Inappropriate shocks were not considered except those due to lead malfunction requiring lead revision. //
Results: Acute complications occurred in 148 patients (4.9%), without significant difference between groups, even after considering potential confounders (OR=1.20, 95% CI 0.72 to 2.00, p=0.47). During a mean follow-up of 41.4±29 months, late complications occurred in 475 patients, giving an annual incidence rate of 26 (95% CI 9 to 43) and 15 (95% CI 6 to 24) per 1000 patient-years in CRT-D and CRT-P patients, respectively. CRT-D was independently associated with increased occurrence of late complications (HR=1.68, 95% CI 1.27 to 2.23, p=0.001). In particular, when compared with CRT-P, CRT-D was associated with an increased risk of device-related infection (HR 2.10, 95% CI 1.18 to 3.45, p=0.004). Acute complications did not predict overall late complications, but predicted device-related infection (HR 2.85, 95% CI 1.71 to 4.56, p<0.001). //
Conclusions: Compared with CRT-P, CRT-D is associated with a similar risk of periprocedural complications but increased risk of long-term complications, mainly infection. This needs to be considered in the decision of implanting CRT with or without a defibrillator
- …