23 research outputs found

    Laboratory experiments on cohesive soil bed fluidization by water waves

    Get PDF
    Part I. Relationships between the rate of bed fluidization and the rate of wave energy dissipation, by Jingzhi Feng and Ashish J. Mehta and Part II. In-situ rheometry for determining the dynamic response of bed, by David J.A. Williams and P. Rhodri Williams. A series of preliminary laboratory flume experiments were carried out to examine the time-dependent behavior of a cohesive soil bed subjected to progressive, monochromatic waves. The bed was an aqueous, 50/50 (by weight) mixture of a kaolinite and an attapulgite placed in a plexiglass trench. The nominal bed thickness was 16 cm with density ranging from 1170 to 1380 kg/m 3, and water above was 16 to 20 cm deep. Waves of design height ranging from 2 to 8 cm and a nominal frequency of 1 Hz were run for durations up to 2970 min. Part I of this report describes experiments meant to examine the rate at which the bed became fluidized, and its relation to the rate of wave energy dissipation. Part II gives results on in-situ rheometry used to track the associated changes in bed rigidity. Temporal and spatial changes of the effective stress were measured during the course of wave action, and from these changes the bed fluidization rate was calculated. A wave-mud interaction model developed in a companion study was employed to calculate the rate of wave energy dissipation. The dependence of the rate of fluidization on the rate of energy dissipation was then explored. Fluidization, which seemingly proceeded down from the bed surface, occurred as a result of the loss of structural integrity of the soil matrix through a buildup of the excess pore pressure and the associated loss of effective stress. The rate of fluidization was typically greater at the beginning of wave action and apparently approached zero with time. This trend coincided with the approach of the rate of energy dissipation to a constant value. In general it was also observed that, for a given wave frequency, the larger the wave height the faster the rate of fluidization and thicker the fluid mud layer formed. On the other hand, increasing the time of bed consolidation prior to wave action decreased the fluidization rate due to greater bed rigidity. Upon cessation of wave action structural recovery followed. Dynamic rigidity was measured by specially designed, in situ shearometers placed in the bed at appropriate elevations to determine the time-dependence of the storage and loss moduli, G' and G", of the viscoelastic clay mixture under 1 Hz waves. As the inter-particle bonds of the space-filling, bed material matrix weakened, the shear propagation velocity decreased measurably. Consequently, G' decreased and G" increased as a transition from dynamically more elastic to more viscous response occurred. These preliminary experiments have demonstrated the validity of the particular rheometric technique used, and the critical need for synchronous, in-situ measurements of pore pressures and moduli characterizing bed rheology in studies on mud fluidization. This study was supported by WES contract DACW39-90-K-0010. (This document contains 151 pages.

    Hydrophilic microporous membranes for selective ion separation and flow-battery energy storage

    Get PDF
    Membranes with fast and selective ion transport are widely used for water purification and devices for energy conversion and storage including fuel cells, redox flow batteries and electrochemical reactors. However, it remains challenging to design cost-effective, easily processed ion-conductive membranes with well-defined pore architectures. Here, we report a new approach to designing membranes with narrow molecular-sized channels and hydrophilic functionality that enable fast transport of salt ions and high size-exclusion selectivity towards small organic molecules. These membranes, based on polymers of intrinsic microporosity containing Tröger’s base or amidoxime groups, demonstrate that exquisite control over subnanometre pore structure, the introduction of hydrophilic functional groups and thickness control all play important roles in achieving fast ion transport combined with high molecular selectivity. These membranes enable aqueous organic flow batteries with high energy efficiency and high capacity retention, suggesting their utility for a variety of energy-related devices and water purification processes

    i-Rheo: Measuring the materials' linear viscoelastic properties “in a step”!

    Get PDF
    A new analytical technique for determining a materials' linear viscoelastic properties from a simple step-strain measurement is reported. The technique avoids the need for idealisation of real measurements. The technique involves evaluating the Fourier transforms of raw experimental data describing both the time-dependent stress and strain functions. A comparison with conventional linear oscillatory measurements for a diverse range of complex materials is made and the technique is shown to be superior to existing linear oscillatory measurements in all cases

    Abnormal clot microstructure formed in blood containing HIT-like antibodies

    Get PDF
    IntroductionThrombosis is a severe and frequent complication of heparin-induced thrombocytopenia (HIT). However, there is currently no knowledge of the effects of HIT-like antibodies on the resulting microstructure of the formed clot, despite such information being linked to thrombotic events. We evaluate the effect of the addition of pathogenic HIT-like antibodies to blood on the resulting microstructure of the formed clot.Materials and methodsPathogenic HIT-like antibodies (KKO) and control antibodies (RTO) were added to samples of whole blood containing Unfractionated Heparin and Platelet Factor 4. The formed clot microstructure was investigated by rheological measurements (fractal dimension; df) and scanning electron microscopy (SEM), and platelet activation was measured by flow cytometry.Results and conclusionsOur results revealed striking effects of KKO on clot microstructure. A significant difference in df was found between samples containing KKO (df = 1.80) versus RTO (df = 1.74; p < 0.0001). This increase in df was often associated with an increase in activated platelets. SEM images of the clots formed with KKO showed a network consisting of a highly branched and compact arrangement of thin fibrin fibres, typically found in thrombotic disease. This is the first study to identify significant changes in clot microstructure formed in blood containing HIT-like antibodies. These observed alterations in clot microstructure can be potentially exploited as a much-needed biomarker for the detection, management and monitoring of HIT-associated thrombosis

    The effect of sepsis and its inflammatory response on mechanical clot characteristics: a prospective observational study

    Get PDF
    Purpose: Sepsis and its progression are known to have a major influence on the coagulation system. Current coagulation tests are of limited use when assessing coagulation in sepsis patients. This study aims to assess the potential for a new functional biomarker of clot microstructure, fractal dimension, to identify changes in the mechanical properties of clot microstructure across the sepsis spectrum (sepsis, severe sepsis and septic shock). Methods: A total of 100 patients that presented acutely to a large teaching hospital were included in this prospective observational study (50 sepsis, 20 severe sepsis and 30 septic shock) against a matched control of 44 healthy volunteers. Fractal analysis was performed, as well as standard markers of coagulation, and six plasma markers of inflammation. Results: Fractal dimension was significantly higher in the sepsis and severe sepsis groups than the healthy control (1.78 ± 0.07 and 1.80 ± 0.05 respectively vs 1.74 ± 0.03) (p < 0.001), indicating a significant increase in mechanical clot strength and elasticity consistent with a hypercoagulable state. Conversely, fractal dimension was significantly lower in septic shock (1.66 ± 0.10, p < 0.001), indicating a significant reduction in mechanical clot strength and functionality consistent with a hypocoagulable state. This corresponded with a significant increase in the inflammatory response. Conclusions: This study confirms that clot microstructure is significantly altered through the various stages of sepsis. Of particular importance was the marked change in clot development between severe sepsis and septic shock, which has not been previously reported

    Quantifying sources of variability in infancy research using the infant-directed-speech preference

    Get PDF
    Psychological scientists have become increasingly concerned with issues related to methodology and replicability, and infancy researchers in particular face specific challenges related to replicability: For example, high-powered studies are difficult to conduct, testing conditions vary across labs, and different labs have access to different infant populations. Addressing these concerns, we report on a large-scale, multisite study aimed at (a) assessing the overall replicability of a single theoretically important phenomenon and (b) examining methodological, cultural, and developmental moderators. We focus on infants’ preference for infant-directed speech (IDS) over adult-directed speech (ADS). Stimuli of mothers speaking to their infants and to an adult in North American English were created using seminaturalistic laboratory-based audio recordings. Infants’ relative preference for IDS and ADS was assessed across 67 laboratories in North America, Europe, Australia, and Asia using the three common methods for measuring infants’ discrimination (head-turn preference, central fixation, and eye tracking). The overall meta-analytic effect size (Cohen’s d) was 0.35, 95% confidence interval = [0.29, 0.42], which was reliably above zero but smaller than the meta-analytic mean computed from previous literature (0.67). The IDS preference was significantly stronger in older children, in those children for whom the stimuli matched their native language and dialect, and in data from labs using the head-turn preference procedure. Together, these findings replicate the IDS preference but suggest that its magnitude is modulated by development, native-language experience, and testing procedure. (This project has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie SkƂodowska-Curie grant agreement No 798658.

    Rare coding variants in PLCG2, ABI3, and TREM2 implicate microglial-mediated innate immunity in Alzheimer's disease

    Get PDF
    We identified rare coding variants associated with Alzheimer’s disease (AD) in a 3-stage case-control study of 85,133 subjects. In stage 1, 34,174 samples were genotyped using a whole-exome microarray. In stage 2, we tested associated variants (P<1×10-4) in 35,962 independent samples using de novo genotyping and imputed genotypes. In stage 3, an additional 14,997 samples were used to test the most significant stage 2 associations (P<5×10-8) using imputed genotypes. We observed 3 novel genome-wide significant (GWS) AD associated non-synonymous variants; a protective variant in PLCG2 (rs72824905/p.P522R, P=5.38×10-10, OR=0.68, MAFcases=0.0059, MAFcontrols=0.0093), a risk variant in ABI3 (rs616338/p.S209F, P=4.56×10-10, OR=1.43, MAFcases=0.011, MAFcontrols=0.008), and a novel GWS variant in TREM2 (rs143332484/p.R62H, P=1.55×10-14, OR=1.67, MAFcases=0.0143, MAFcontrols=0.0089), a known AD susceptibility gene. These protein-coding changes are in genes highly expressed in microglia and highlight an immune-related protein-protein interaction network enriched for previously identified AD risk genes. These genetic findings provide additional evidence that the microglia-mediated innate immune response contributes directly to AD development

    FEDSM2002-31020 MEASUREMENTS OF THE EFFECTIVE TENSILE STRENGTH OF NEWTONIAN AND NON-NEWTONIAN FLUIDS UNDER DYNAMIC STRESSING

    No full text
    ABSTRACT The &apos;Bullet-Piston&apos;(B-P) dynamic stressing technique has been used to study the tensile strength, F c , of Newtonian and non-Newtonian fluids. A comparative study of the effects of viscosity on F c for silicone oils (Newtonian) and aqueous polyacrylamide (PAA) solutions (non-Newtonian) was made. Both systems exhibited a power law dependency of the form F c ∝ ”

    Rheometrical Studies of Blood Clot Formation by Oscillatory Shear, Thromboelastography, Sonoclot Analysis and Free Oscillation Rheometry

    No full text
    We report studies of the coagulation of samples of whole human blood by oscillatory shear techniques, including Fourier Transform Mechanical Spectroscopy (FTMS). These techniques are used herein to identify the Gel Point of coagulating blood in terms of the Chambon‐Winter Gel Point criterion which provides a rheometrical basis for detecting the establishment of an incipient clot. A comparison of the results of FTMS with those obtained from measurements involving a Thromboelastograph (TEG), a Sonoclot Analyzer and a Free Oscillation Rheometer (FOR) indicate that the latter techniques are not capable of detecting the incipient clot, whose establishment occurs several minutes prior to TEG or FOR‐based assessments of clot formation time. The results of the present study suggest that FTMS is a useful tool in blood clotting research, being capable of providing a global coagulation profile in addition to detecting the instant of incipient clot formation
    corecore