66 research outputs found

    Experimentally-determined characteristics of radiant systems for office buildings

    Get PDF
    Radiant heating and cooling systems have significant energy-saving potential and are gaining popularity in commercial buildings. The main aim of the experimental study reported here was to characterize the behavior of radiant cooling systems in a typical office environment, including the effect of ceiling fans on stratification, the variation in comfort conditions from perimeter to core, control on operative temperature vs. air temperature and the effect of carpet on cooling capacity. The goal was to limit both the first cost and the perceived risk associated with such systems. Two types of radiant systems, the radiant ceiling panel (RCP) system and the radiant slab (RS) system, were investigated. The experiments were carried out in one of the test cells that constitute the FLEXLAB test facility at the Lawrence Berkeley National Laboratory in March and April 2016. In total, ten test cases (five for RCP and five for RS) were performed, covering a range of operational conditions. In cooling mode, the air temperature stratification is relatively small in the RCP, with a maximum value of 1.6 K. The observed stratification effect was significantly greater in the RS, twice as much as that in the RCP. The maximum increase in dry bulb temperature in the perimeter zone due to solar radiation was 1.2 K for RCP and 0.9 K for RS – too small to have a significant impact on thermal comfort. The use of ceiling fans was able to reduce any excess stratification and provide better indoor comfort, if required. The use of thin carpet requires a 1 K lower supply chilled water temperature to compensate for the added thermal resistance, somewhat reducing the opportunities for water-side free cooling and increasing the risk of condensation. In both systems, the difference between the room operative temperature and the room air temperature is small when the cooling loads are met by the radiant systems. This makes it possible to use the air temperature to control the radiant systems in lieu of the operative temperature, reducing both first cost and maintenance costs

    An epidemiological approach to simulation-based analysis of large building stocks

    Get PDF
    This paper describes a novel approach to building stock energy modelling: Individual building simulation models are autogenerated for each building in the stock, and the resulting set of virtual buildings is selectively sampled, simulated and analysed in much the same way that an epidemiologist might study a population through surveys and statistical analysis. A conceptual and software framework is described, along with initial case study results for a London borough

    Comparison of Chiller Models for Use in Model-Based Fault Detection

    Get PDF
    Selecting the model is an important and essential step in model based fault detection and diagnosis (FDD). Factors that are considered in evaluating a model include accuracy, training data requirements, calibration effort, generality, and computational requirements. The objective of this study was to evaluate different modeling approaches for their applicability to model based FDD of vapor compression chillers. Three different models were studied: the Gordon and Ng Universal Chiller model (2nd generation) and a modified version of the ASHRAE Primary Toolkit model, which are both based on first principles, and the DOE-2 chiller model, as implemented in CoolToolsTM, which is empirical. The models were compared in terms of their ability to reproduce the observed performance of an older, centrifugal chiller operating in a commercial office building and a newer centrifugal chiller in a laboratory. All three models displayed similar levels of accuracy. Of the first principles models, the Gordon-Ng model has the advantage of being linear in the parameters, which allows more robust parameter estimation methods to be used and facilitates estimation of the uncertainty in the parameter values. The ASHRAE Toolkit Model may have advantages when refrigerant temperature measurements are also available. The DOE-2 model can be expected to have advantages when very limited data are available to calibrate the model, as long as one of the previously identified models in the CoolTools library matches the performance of the chiller in question

    Testing and demonstration of model predictive control applied to a radiant slab cooling system in a building test facility

    Get PDF
    Radiant slab systems have the potential to significantly reduce energy consumption in buildings. However, control of radiant slab systems is challenging. Classical feedback control is inadequate due to the large thermal inertia of the systems and heuristic feed-forward control often leads to unacceptable indoor comfort and may not achieve the full energy savings potential. Model predictive control (MPC) is now attracting increasing interest in the building industry and holds promise for radiant systems. However, an often-cited barrier to its implementation in the building industry is the high computational cost and complexity relative to the feedback controls used in conventional systems. The objectives of this study were to (i) verify the correct operation of an open source MPC toolchain developed for radiant slab systems, and (ii) demonstrate its efficacy in a test facility. A matched pair of cells in the FLEXLAB building test facility at the Lawrence Berkeley National Laboratory was used in the study. The proposed MPC toolchain was implemented in one cell and the performance compared to that of the other cell, which used a conventional heuristic control strategy. The results showed that the simplified MPC approach applied in the toolchain worked as expected and realized energy savings over the conventional control strategy. The MPC yielded 42% chilled water pump power reduction and 16% cooling thermal energy savings, while maintaining equal or better indoor comfort

    Demand Relief and Weather Sensitivity in Large California Commercial Office Buildings

    Get PDF
    A great deal of research has examined the weather sensitivity of energy consumption in commercial buildings; however, the recent power crisis in California has given greater importance to peak demand. Several new loadshedding programs have been implemented or are under consideration. Historically, the target customers have been large industrial users who can reduce the equivalent load of several large office buildings. While the individual load reduction from an individual office building may be less significant, there is ample opportunity for load reduction in this area. The load reduction programs and incentives for industrial customers may not be suitable for commercial building owners. In particular, industrial customers are likely to have little variation in load from day to day. Thus a robust baseline accounting for weather variability is required to provide building owners with realistic targets that will encourage them to participate in load shedding programs

    Weak-Lensing by Large-Scale Structure and the Polarization Properties of Distant Radio-Sources

    Get PDF
    We estimate the effects of weak lensing by large-scale density inhomogeneities and long-wavelength gravitational waves upon the polarization properties of electromagnetic radiation as it propagates from cosmologically distant sources. Scalar (density) fluctuations do not rotate neither the plane of polarization of the electromagnetic radiation nor the source image. They produce, however, an appreciable shear, which distorts the image shape, leading to an apparent rotation of the image orientation relative to its plane of polarization. In sources with large ellipticity the apparent rotation is rather small, of the order (in radians) of the dimensionless shear. The effect is larger at smaller source eccentricity. A shear of 1% can induce apparent rotations of around 5 degrees in radio sources with the smallest eccentricity among those with a significant degree of integrated linear polarization. We discuss the possibility that weak lensing by shear with rms value around or below 5% may be the cause for the dispersion in the direction of integrated linear polarization of cosmologically distant radio sources away from the perpendicular to their major axis, as expected from models for their magnetic fields. A rms shear larger than 5% would be incompatible with the observed correlation between polarization properties and source orientation in distant radio galaxies and quasars. Gravity waves do rotate both the plane of polarization as well as the source image. Their weak lensing effects, however, are negligible.Comment: 23 pages, 2 eps figures, Aastex 4.0 macros. Final version, as accepted by ApJ. Additional references and some changes in the introduction and conclusion

    Comments on Non-Commutative Phenomenology

    Full text link
    It is natural to ask whether non-commutative geometry plays a role in four dimensional physics. By performing explicit computations in various toy models, we show that quantum effects lead to violations of Lorentz invariance at the level of operators of dimension three or four. The resulting constraints are very stringent.Comment: Correction of an error in the U(1) and U(N) calculation leads to stronger limits than those given previously Clarifying comments and reference adde

    Is there evidence for cosmic anisotropy in the polarization of distant radio sources?

    Get PDF
    Measurements of the polarization angle and orientation of cosmological radio sources may be used to search for unusual effects in the propagation of light through the universe. Recently, Nodland and Ralston (astro-ph/9704196) have claimed to find evidence for a redshift- and direction-dependent rotation effect in existing data. We re-examine these data and argue that there is no statistically significant signal present. We are able to place stringent limits on hypothetical chiral interactions of photons propagating through spacetime.Comment: 17 pages, including 7 figures. (Arithmetic error corrected, fixing value of chi^2

    Optical Activity of a Neutrino Gas

    Get PDF
    For photons that propagate through a gas of neutrinos with a non-zero chemical potential, the left-handed and right-handed polarization modes acquire different dispersion relations. This is due to the CP and CPT-odd terms induced by such a background on the photon self-energy. We present a detailed calculation of this effect, which does not depend on any physical assumptions beyond those of the standard electroweak model. Some possible cosmological and astrophysical implications of our results are considered in several contexts, including the recent discussions regarding the rotation of the plane of polarization of electromagnetic waves over cosmological distances.Comment: latex, axodra

    Brain inflammation is accompanied by peripheral inflammation in Cstb(-/-) mice, a model for progressive myoclonus epilepsy

    Get PDF
    Progressive myoclonus epilepsy of Unverricht-Lundborg type (EPM1) is an autosomal recessively inherited childhood-onset neurodegenerative disorder, characterized by myoclonus, seizures, and ataxia. Mutations in the cystatin B gene (CSTB) underlie EPM1. The CSTB-deficient (Cstb(-/-)) mouse model recapitulates key features of EPM1, including myoclonic seizures. The mice show early microglial activation that precedes seizure onset and neuronal loss and leads to neuroinflammation. We here characterized the inflammatory phenotype of Cstb(-/-) mice in more detail. We found higher concentrations of chemokines and pro-inflammatory cytokines in the serum of Cstb(-/-) mice and higher CXCL13 expression in activated microglia in Cstb(-/-) compared to control mouse brains. The elevated chemokine levels were not accompanied by blood-brain barrier disruption, despite increased brain vascularization. Macrophages in the spleen and brain of Cstb(-/-) mice were predominantly pro-inflammatory. Taken together, these data show that CXCL13 expression is a hallmark of microglial activation in Cstb(-/-)mice and that the brain inflammation is linked to peripheral inflammatory changes, which might contribute to the disease pathology of EPM1.Peer reviewe
    • …
    corecore