683 research outputs found

    Rapid Profiling of Marine Notches Using a Handheld Laser Distance Meter

    Get PDF
    A rapid, single-user profiling method for rocky shores is described. The Leica Disto D8 handheld laser distance meter measures distance up to 100 m and inclination in 360 degrees. It automatically calculates horizontal distance and vertical elevation. Memory storage accommodates data for 30 measurement points, allowing easy plotting of shore profiles. This technique allows even inaccessible, dangerous, and overhanging cliff faces to be evaluated faithfully and within minutes. It is a major improvement over standard methods that often involve risky coasteering and climbing. Examples are given from marine notches in Thailand

    Voxel-based magnetic resonance image postprocessing in epilepsy

    Get PDF
    OBJECTIVE: Although the general utility of voxel-based processing of structural magnetic resonance imaging (MRI) data for detecting occult lesions in focal epilepsy is established, many differences exist among studies, and it is unclear which processing method is preferable. The aim of this study was to compare the ability of commonly used methods to detect epileptogenic lesions in magnetic resonance MRI-positive and MRI-negative patients, and to estimate their diagnostic yield. METHODS: We identified 144 presurgical focal epilepsy patients, 15 of whom had a histopathologically proven and MRI-visible focal cortical dysplasia; 129 patients were MRI negative with a clinical hypothesis of seizure origin, 27 of whom had resections. We applied four types of voxel-based morphometry (VBM), three based on T1 images (gray matter volume, gray matter concentration, junction map [JM]) and one based on normalized fluid-attenuated inversion recovery (nFSI). Specificity was derived from analysis of 50 healthy controls. RESULTS: The four maps had different sensitivity and specificity profiles. All maps showed detection rates for focal cortical dysplasia patients (MRI positive and negative) of >30% at a strict threshold of p 60% with a liberal threshold of p < 0.0001 (uncorrected), except for gray matter volume (14% and 27% detection rate). All maps except nFSI showed poor specificity, with high rates of false-positive findings in controls. In the MRI-negative patients, absolute detection rates were lower. A concordant nFSI finding had a significant positive odds ratio of 7.33 for a favorable postsurgical outcome in the MRI-negative group. Spatial colocalization of JM and nFSI was rare, yet showed good specificity throughout the thresholds. SIGNIFICANCE: All VBM variants had specific diagnostic properties that need to be considered for an adequate interpretation of the results. Overall, structural postprocessing can be a useful tool in presurgical diagnostics, but the low specificity of some maps has to be taken into consideration

    Role of the Recoil Ion in Single-Electron Capture and Single-Ionization Processes for Collisions of Protons with He and Ar Atoms

    Get PDF
    In this work the single-electron capture and single-ionization processes are studied for proton collisions with He and Ar atoms at impact energies in the range 25–100 keV. Classical trajectory Monte Carlo simulations are benchmarked against experimental data obtained at the reaction microscope in Bariloche, Argentina, which employs the cold target recoil-ion momentum spectroscopy technique. Special emphasis is placed on describing the momentum transfer to the recoil ion for these collision systems

    USA Observation of Spectral and Timing Evolution During the 2000 Outburst of XTE J1550-564

    Get PDF
    We report on timing and spectral observations of the 2000 outburst of XTE J1550-564 made by the Unconventional Stellar Aspect (USA) Experiment on board the Advanced Research and Global Observation Satellite (ARGOS). We observe a low-frequency quasi-periodic oscillation (LFQPO) with a centroid frequency that tends to increase with increasing flux and a fractional rms amplitude which is correlated with the hardness ratio. The evolution of the hardness ratio (4--16 keV/1--4 keV) with time and source flux is examined. The hardness-intensity diagram (HID) shows a cyclical movement in the clockwise direction and possibly indicates the presence of two independent accretion flows. We observe a relationship between the USA 4--16 keV count rate and radio observations and discuss this in the context of previously observed correlations between X-ray, radio, optical and IR data. We examine our results in the context of models invoking two accretion flows: a thin disk and a hot sub-Keplerian flow.Comment: 11 pages, 2 figure

    Beyond the Dipole Approximation: Angular-Distribution Effects in the 1s Photoemission from Small Molecules

    Full text link
    Over the past two decades, the dipole approximation has facilitated a basic understanding of the photoionization process in atoms and molecules. Recent experiments on the 1s inner shells of small molecules at relatively low photon energies (⩽ 1000 eV) show strong nondipole effects. They are significant and measurable at energies close to threshold, in conflict with a common assumption that the dipole approximation is valid for photon energies below 1 keV

    BoGSy:ein Informationssystem für Botanische Gärten

    Full text link
    Botanische Gärten bieten den Botanischen Instituten die Grundlage für deren Forschungen und Besuchern einen Einblick in die Pflanzenwelt. Die mit dem Wissenschaftszweig der Botanik entstanden Universitätsgärten haben ihren Mittelpunkt in der Botanischen Forschung und Lehre, vor allem in den Bereichen Taxonomie und Ökologie. Die Grundlagen und der Inhalt der Botanischen Arbeit sind demnach insbesondere Sammlungen. Darüber hinaus erfordert die Teilnahme im IPEN (International Plant Exchange Network) seit einigen Jahren die Einhaltung strenger Kriterien der CBD (Convention on Biological Diversity) beim Austausch von Samen und Pflanzenmaterial. Die Entwicklung eines Datenbank gestützten Informationssystems für Botanische Gärten wird durch eine Reihe von Beobachtungen motiviert und muss diverse Randbedingungen beachten. Dies wird im Folgenden genauer erläutert. Sodann werden der Entwurf und eine erste Realisierung des Informationssystems BoGSy beschrieben, welches an der Universität Münster entwickelt wird und diesen Bedingungen genügt.<br/

    Relativistic Effects on Interchannel Coupling in Atomic Photoionization: The Photoelectron Angular Distribution of Xe

    Full text link
    Measurements of the photoelectron angular-distribution asymmetry parameter β for Xe 5s photoionization have been performed in the 80–200 eV photon-energy region. The results show a substantial deviation from the nonrelativistic value of β=2 and provide a clear signature of significant relativistic effects in interchannel coupling

    Large Nondipole Effects in the Angular Distributions of K-Shell Photoelectrons from Molecular Nitrogen

    Full text link
    Measurements of angular distributions of K-shell electrons photoejected from molecular nitrogen are reported which reveal large deviations at relatively low photon energies ( ħω≤500eV) from emission patterns anticipated from the dipole approximation to interactions between radiation and matter. A concomitant theoretical analysis incorporating the effects of electromagnetic retardation attributes the observed large nondipole behaviors in N2 to bond-length-dependent terms in the E1⊗(E2,M1) photoelectron emission amplitudes which are indicative of a potentially universal nondipole behavior in molecular photoionization

    Validity of the Independent-Particle Approximation in X-Ray Photoemission: The Exception, Not the Rule

    Full text link
    A combined experimental and theoretical study of argon valence photoionization illustrates the discovery of the broad lack of validity of the independent-particle approximation (IPA) for x-ray photoemission. In addition to previously known breakdowns of the IPA, which are limited to high photon energies and regions very near threshold, the observed breakdown in photoionization at intermediate energies demonstrates generally that the IPA is valid only in very restricted domains. These restrictions are expected to be relevant throughout the periodic table, with consequences for a wide variety of applications

    Interchannel Coupling in the Photoionization of the M-shell of Kr Well Above Threshold: Experiment and Theory

    Full text link
    Photoionization cross sections and asymmetry (β) parameters for Kr 3s, 3p, and 3d subshells have been measured and calculated in the 300–1300-eV photon energy range. Good agreement between experiment and theory is found for both cross-section branching ratios and β parameters. Interchannel coupling among the channels arising from 3s, 3p, and 3d subshells is found to be necessary for quantitative accuracy of the theory. This shows that the interchannel coupling phenomenology far above threshold, found previously for outer shells of Ne and Ar, is also operative for inner atomic shells
    • …
    corecore