166 research outputs found
The Fast Read-out System for the MAPMTs of COMPASS RICH-1
A fast readout system for the upgrade of the COMPASS RICH detector has been
developed and successfully used for data taking in 2006 and 2007. The new
readout system for the multi-anode PMTs in the central part of the photon
detector of the RICH is based on the high-sensitivity MAD4
preamplifier-discriminator and the dead-time free F1-TDC chip characterized by
high-resolution. The readout electronics has been designed taking into account
the high photon flux in the central part of the detector and the requirement to
run at high trigger rates of up to 100 kHz with negligible dead-time. The
system is designed as a very compact setup and is mounted directly behind the
multi-anode photomultipliers. The data are digitized on the frontend boards and
transferred via optical links to the readout system. The read-out electronics
system is described in detail together with its measured performances.Comment: Proceeding of RICH2007 Conference, Trieste, Oct. 2007. v2: minor
change
Pencegahan dan Penyelesaian Kekerasan dalam Rumah Tangga di Masa Pandemi Covid-19
Pada saat seorang pria menikah dengan seorang wanita maka timbulah suatu ikatan lahir batin sebagai pasangan suami-istri yang bertujuan membentuk keluarga yang bahagia dan kekal. Perkawinan di Indonesia memiliki hubungan yang erat sekali dengan agama/kerohanian yang dianut oleh pasangan, sehingga perkawinan tidak saja mengandung unsur lahir/jasmani, tetapi juga unsur bathin/rohani. Pengabdian kepada masyarakat di Kampung Babakan Ngantai, Desa Singasari, Kecamatan Jonggol, Kabupaten Bogor, Jawa Barat dilakukan sebagai bentuk Pengabdian Kepada Masyarakat (PKM) Fakultas Hukum Universitas Kristen Indonesia dalam rangka program pemberdayaan masyarakat serta meningkatkan solidaritas dan kepedulian kepada kondisi masyarakat, khususnya yang membutuhkan bantuan hukum, khususnya di tengah pandemi Covid-19. Tema PPM ini kami ambil karena permasalahan mengenai hukum keluarga adalah masalah yang seringkali dihadapi masyarakat di dalam kehidupan sehari-hari. PKM dilaksanakan dengan cara ceramah, diskusi, tanya jawab serta dilakukan evaluasi melalui penyebaran kuesioner kepada peserta. Pengabdian dilaksanakan oleh tim dosen FH UKI yang berkompeten di bidang hukum keluarga. Hasil dari PKM penyuluhan hukum keluarga membuat bertambahnya pengetahuan dan pemahaman warga Desa Singasari tentang hukum keluarga dan permasalahan perkawinan yang dihadapinya.
Kata Kunci: Hukum Keluarga, Penyuluhan Hukum, Perkawina
Background studies and shielding effects for the TPC detector of the CAST experiment
Sunset solar axions traversing the intense magnetic field of the CERN Axion
Solar Telescope (CAST) experiment may be detected in a Time Projection Chamber
(TPC) detector, as X-rays signals. These signals could be masked, however, by
the inhomogeneous background of materials in the experimental site. A detailed
analysis, based on the detector characteristics, the background radiation at
the CAST site, simulations and experimental results, has allowed us to design a
shielding which reduces the background level by a factor of ~4 compared to the
detector without shielding, depending on its position, in the energy range
between 1 and 10 keV. Moreover, this shielding has improved the homogeneity of
background measured by the TPC.Comment: 14 pages, 5 figures, accepted in New Journal of Physic
A low background Micromegas detector for the CAST experiment
A low background Micromegas detector has been operating on the CAST
experiment at CERN for the search of solar axions during the first phase of the
experiment (2002-2004). The detector operated efficiently and achieved a very
low level of background rejection ( counts
keVcms) thanks to its good spatial and energy resolution
as well as the low radioactivity materials used in the construction of the
detector. For the second phase of the experiment (2005-2007), the detector will
be upgraded by adding a shielding and including focusing optics. These
improvements should allow for a background rejection better than two orders of
magnitude.Comment: 6 pages, 3 figures To appear on the proceedings of the 9th ICATPP
Conference on AStroparticle, Particle, Space Physics, Detectors and Medical
Physics Application
Radiative corrections to neutral pion-pair production
We calculate the one-photon loop radiative corrections to the neutral
pion-pair photoproduction process . At leading
order this reaction is governed by the chiral pion-pion interaction. Since the
chiral contact-vertex depends only on the final-state
invariant-mass it factors out of all photon-loop diagrams. We give analytical
expressions for the multiplicative correction factor
arising from eight classes of contributing one-photon loop diagrams. An
electromagnetic counterterm has to be included in order to cancel the
ultraviolet divergences generated by the photon-loops. Infrared finiteness of
the virtual radiative corrections is achieved (in the standard way) by
including soft photon radiation below an energy cut-off . The
radiative corrections to the total cross section vary between and
for center-of-mass energies from threshold up to . The finite part of
the electromagnetic counterterm gives an additional constant contribution of
about , however with a large uncertainty.Comment: 10 pages, 6 figures, submitted to Eur. Phys. J.
New pixelized Micromegas detector with low discharge rate for the COMPASS experiment
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of
the future physics projects planned by the COMPASS collaboration at CERN.
Several major upgrades compared to present detectors are being studied:
detectors standing five times higher luminosity with hadron beams, detection of
beam particles (flux up to a few hundred of kHz/mm^{2}, 10 times larger than
for the present Micromegas detectors) with pixelized read-out in the central
part, light and integrated electronics, and improved robustness. Two solutions
of reduction of discharge impact have been studied, with Micromegas detectors
using resistive layers and using an additional GEM foil. Performance of such
detectors has also been measured. A large size prototypes with nominal active
area and pixelized read-out has been produced and installed at COMPASS in 2010.
In 2011 prototypes featuring an additional GEM foil, as well as an resistive
prototype, are installed at COMPASS and preliminary results from those
detectors presented very good performance. We present here the project and
report on its status, in particular the performance of large size prototypes
with an additional GEM foil.Comment: 11 pages, 5 figures, proceedings to the Micro-Pattern Gaseous
Detectors conference (MPGD2011), 29-31 August 2011, Kobe, Japa
Fast readout of the COMPASS RICH CsI-MWPC photon chambers
Abstract A new readout system for CsI-coated MWPCs, used in the COMPASS RICH detector, has been proposed and tested in nominal high-rate conditions. It is based on the APV25-S1 analog sampling chip, and will replace the Gassiplex chip readout used up to now. The APV chip, originally designed for silicon microstrip detectors, is shown to perform well even with "slow" signals from a MWPC, keeping a signal-to-noise ratio of 9. For every trigger the system reads three consecutive in-time samples, thus allowing to extract information on the signal shape and its timing. The effective time window is reduced from ∼3 μs for the Gassiplex to below 400 ns for the APV25-S1 chip, reducing pile-up events at high particle rate. A significant improvement of the signal-to-background ratio by a factor 5–6 with respect to the original readout has been measured in the central region of the RICH detector. Due to its pipelined architecture, the new readout system also considerably reduces the dead time per event, allowing efficient data taking at higher trigger rate
Pattern recognition and PID for COMPASS RICH-1
A package for pattern recognition and PID by COMPASS RICH-1 has been
developed and used for the analysis of COMPASS data collected in the years 2002
to 2004, and 2006-2007 with the upgraded RICH-1 photon detectors. It has
allowed the full characterization of the detector in the starting version and
in the upgraded one, as well as the PID for physics results. We report about
the package structure and algorithms, and the detector characterization and PID
results.Comment: 4 pages, 4 figures,to appear in the proceedings of 6th International
Workshop on Ring Imaging Cherenkov Counters (RICH 2007), Trieste, Italy,
15-20 Oct 200
The Micromegas detector of the CAST experiment
A low background Micromegas detector has been operating in the CAST
experiment at CERN for the search of solar axions during the first phase of the
experiment (2002-2004). The detector, made out of low radioactivity materials,
operated efficiently and achieved a very low level of background rejection (5 x
10^-5 counts/keV/cm^2/s) without shielding.Comment: 13 pages, 12 figures and images, submitted to New Journal o
The CAST Time Projection Chamber
One of the three X-ray detectors of the CAST experiment searching for solar
axions is a Time Projection Chamber (TPC) with a multi-wire proportional
counter (MWPC) as a readout structure. Its design has been optimized to provide
high sensitivity to the detection of the low intensity X-ray signal expected in
the CAST experiment. A low hardware threshold of 0.8 keV is safely set during
normal data taking periods, and the overall efficiency for the detection of
photons coming from conversion of solar axions is 62 %. Shielding has been
installed around the detector, lowering the background level to 4.10 x 10^-5
counts/cm^2/s/keV between 1 and 10 keV. During phase I of the CAST experiment
the TPC has provided robust and stable operation, thus contributing with a
competitive result to the overall CAST limit on axion-photon coupling and mass.Comment: 19 pages, 11 figures and images, submitted to New Journal of Physic
- …