209 research outputs found

    The Effect of Two Sock Fabrics on Perception and Physiological Parameters Associated with Blister Incidence: A Field Study

    Get PDF
    The goal of the present study was to investigate differences in perception and skin hydration at the foot of two sock fabrics with distinct moisture properties in a realistic military setting. Thirty-seven military recruits wore two different socks (PP: 99.6% polypropylene and 0.4% elastane, and BLEND: 50% Merino-wool, 33% polypropylene, and 17% polyamide), one on each foot. Measurements were carried out after a daily 6.5-km march on 4 days. Each participant rated temperature, dampness, friction, and comfort for each foot. On a daily selection of participants, skin hydration was measured on three sites of both feet using a corneometer, and moisture content of the socks was determined. BLEND was rated to be cooler, less damp, and more comfortable (P < 0.05). Two out of three skin sites were drier for BLEND than PP (P < 0.05). Moreover, BLEND stored 2.9 ± 0.3 times more moisture compared to PP. Thus, under the present conditions, socks such as BLEND are to be preferred over polypropylene sock

    The perspective of people with axial spondyloarthritis regarding physiotherapy : room for the implementation of a more active approach

    Get PDF
    Objectives. Physiotherapy is recommended in the management of people with axial spondyloarthritis (axSpA), with new insights into its preferred content and dosage evolving. The aim of this study was to describe the use and preferences regarding individual and group physiotherapy among people with axSpA. Methods. A cross-sectional survey was conducted among people with axSpA living in The Netherlands (NL) and Switzerland (CH). Results. Seven hundred and thirteen people with axSpA participated (56.7% male, median age 55 years, median Assessment of Spondyloarthritis International Society Health Index score 4.2). Response rates were 45% (nÂĽ206) in NL and 29% in CH (nÂĽ507). Of these participants, 83.3% were using or had been using physiotherapy. Individual therapy only was used or had been used by 36.7%, a combination of individual plus land- and water-based group therapy by 29.1% and group therapy by only 5.3%. Fewer than half of the participants attending individual therapy reported active therapy (such as aerobic, muscle strength and flexibility exercises). Although the majority (75.9%) were not aware of the increased cardiovascular risk, participants showed an interest in cardiovascular training, either individually or in a supervised setting. If supervised, a majority, in CH (75.0%) more than in NL (55.7%), preferred supervision by a specialized physiotherapist. Conclusion. The majority of people with axSpA use or have used physiotherapy, more often in an individual setting than in a group setting. The content of individual therapy should be more active; in both therapy settings, aerobic exercises should be promoted. In particular, enabling people with axSpA to perform exercises independently would meet their needs and might enhance their daily physical activity

    Mechanical properties of reactively flame retarded cyanate ester/epoxy resin blends and their carbon fibre reinforced composites

    Get PDF
    Cyanate ester/epoxy resin (CE/EP) carbon fibre reinforced composites consisting of diglycidyl ether of bisphenol A (DGEBA) and novolac type cyanate ester (CE) were prepared and reactively flame retarded using epoxy functional adduct of DGEBA and 9,10-dihydro-9-oxa-10-phosphaphenanthrene-10-oxide (DOPO). Effect of cyanate ester and flame retardant (FR) ratio was determined on matrix viscosity, matrix and composite glass transition temperature (Tg), as well as composite mechanical properties including storage modulus, tensile, bending, interlaminar shear and Charpy impact properties. Although the epoxy resin (EP) and FR decreased the Tg, even the flame retarded CE/EP blends had at least 22 °C higher Tg than the benchmark DGEBA composite. As for the mechanical properties, as a result of higher interlaminar shear strength suggesting better fibre-matrix adhesion, the CE/EP blends managed to over-perform the reference CE in most cases: The 2% phosphorus (P)-containing CE/EP composite had 25% higher tensile strength than the CE reference. The bending strength of the blends remained in the same range as the reference, while the impact resistance significantly increased in comparison to CE, especially in flame retarded composites

    Scaling hetero-epitaxy from layers to three-dimensional crystals

    Get PDF
    Laying It on Thick The growth of one layered material onto a second lies at the heart of many electronic devices. However, if there is a lattice mismatch between the two materials, strains develop in the overgrowth material leading to bowing and cracking. Falub et al. (p. 1330 ; see the cover) patterned Si substrates into a series of pillars onto which they grew a germanium layer. The germanium initially coated the top of each silicon pillar but then widened as the layer thickened, leading to thick, crack-free germanium films. </jats:p

    Reliability of an adapted core strength endurance test battery in individuals with axial spondylarthritis

    Get PDF
    Objectives To adapt the core strength endurance test battery (aCSE), previously used for testing athletes, to a target group of patients with axial spondylarthritis (axSpA), to evaluate its intra-tester reliability and its associationswith disease-specific factors. Methods A cross-sectional study was conducted at axSpA exercise therapy groups, including both axSpA patients and the physiotherapist group leaders (PTs). The aCSE was used to measure the isometric strength endurance of the ventral, lateral, and dorsal core muscle chains (measured in seconds), as well as to assess the disease-specific factors of functional status, selfreported pain, and perceived strength performance. The aCSE was repeated after 7–14 days to measure intra-tester reliability for the same rater (PT group leader). Reliability was calculated as an intra-class correlation coefficient (ICC) using a nested design. The associations between ventral, lateral, and dorsal strength endurance and the disease-specific factors were calculated using Pearson correlation coefficients. Results Study participants were 13 PT group leaders and 62 axSpA patients. The latter were all capable of performing the aCSE, with the exception of one individual. A moderate to substantial intra-rater reliability (ICCs (95%CI)) was found for the ventral (0.54 (0.35, 0.74)), lateral (0.52 (0.33, 0.70)), and dorsal (0.71 (0.58, 0.86)) core muscle chains. None of the aCSE measures correlated with the disease-specific factors. Conclusion The aCSE was found to be a reliable test battery for assessing core strength endurance in axSpA patients. Interestingly, aCSE performance was not associated with any disease-specific factors

    Syngas generation from n-butane with an integrated MEMS assembly for gas processing in micro-solid oxide fuel cell systems

    Get PDF
    An integrated system of a microreformer and a carrier allowing for syngas generation from liquefied petroleum gas (LPG) for micro-SOFC application is discussed. The microreformer with an overall size of 12.7 mm × 12.7 mm × 1.9 mm is fabricated with micro-electro-mechanical system (MEMS) technologies. As a catalyst, a special foam-like material made from ceria-zirconia nanoparticles doped with rhodium is used to fill the reformer cavity of 58.5 mm3. The microreformer is fixed onto a microfabricated structure with built-in fluidic channels and integrated heaters, the so-called functional carrier. It allows for thermal decoupling of the cold inlet gas and the hot fuel processing zone. Two methods for heating the microreformer are compared in this study: a) heating in an external furnace and b) heating with the two built-in heaters on the functional carrier. With both methods, high butane conversion rates of 74%–85% are obtained at around 550 °C. In addition, high hydrogen and carbon monoxide yields and selectivities are achieved. The results confirm those from classical lab reformers built without MEMS technology (N. Hotz et al., Chem. Eng. Sci., 2008, 63, 5193; N. Hotz et al., Appl. Catal., B, 2007, 73, 336). The material combinations and processing techniques enable syngas production with the present MEMS based microreformer with high performance for temperatures up to 700°C. The functional carrier is the basis for a new platform, which can integrate the micro-SOFC membranes and the gas processing unit as subsystem of an entire micro-SOFC system
    • …
    corecore