2,826 research outputs found
Annual and semiannual variations of vertical total electron content during high solar activity based on GPS observations
Annual, semiannual and seasonal variations of the Vertical Total Electron
Content (VTEC) have been investigated during high solar activity in 2000. In
this work we use Global IGS VTEC maps and Principal Component Analysis to
study spatial and temporal ionospheric variability. The behavior of VTEC
variations at two-hour periods, at noon and at night is analyzed. Particular
characteristics associated with each period and the geomagnetic regions are
highlighted.
<br><br>
The variations at night are smaller than those obtained at noon. At noon it
is possible to see patterns of the seasonal variation at high latitude, and
patterns of the semiannual anomaly at low latitudes with a slow decrease
towards mid latitudes. At night there is no evidence of seasonal or annual
anomaly for any region, but it was possible to see the semiannual anomaly at
low latitudes with a sudden decrease towards mid latitudes. In general, the
semiannual behavior shows March–April equinox at least 40 % higher than
September one. Similarities and differences are analyzed also with regard to
the same analysis done for a period of low solar activity
Towards semantic software engineering environments
Software tools processing partially common set of data should share an understanding of what these data mean. Since ontologies have been used to express formally a shared understanding of information, we argue that they are a way towards Semantic SEEs. In this paper we discuss an ontology-based approach to tool integration and present ODE, an ontology-based SEE
Characterization of a defective PbWO4 crystal cut along the a-c crystallographic plane: structural assessment and a novel photoelastic stress analysis
Among scintillators, the PWO is one of the most widely used, for instance in
CMS calorimeter at CERN and PANDA project. Crystallographic structure and
chemical composition as well as residual stress condition, are indicators of
homogeneity and good quality of the crystal. In this paper, structural
characterization of a defective PbWO4 (PWO) crystal has been performed by X-ray
Diffraction (XRD), Energy Dispersive Spectroscopy (EDS) and Photoelasticity in
the unusual a-c crystallographic plane. XRD and EDS analysis have been used to
investigate crystallographic orientation and chemical composition, while stress
distribution, which indicates macroscopic inhomogeneities and defects, has been
obtained by photoelastic approaches, in Conoscopic and Sphenoscopic
configuration. Since the sample is cut along the a-c crystallographic plane, a
new method is proposed for the interpretation of the fringe pattern. The
structural analysis has detected odds from the nominal lattice dimension, which
can be attributed to the strong presence of Pb and W. A strong inhomogeneity
over the crystal sample has been revealed by the photoelastic inspection. The
results give reliability to the proposed procedure which is exploitable in
crystals with other structures.Comment: 18 pages, 10 figures, revised versio
Quantum dynamics of a high-finesse optical cavity coupled with a thin semi-transparent membrane
We study the quantum dynamics of the cavity optomechanical system formed by a
Fabry-Perot cavity with a thin vibrating membrane at its center. We first
derive the general multimode Hamiltonian describing the radiation pressure
interaction between the cavity modes and the vibrational modes of the membrane.
We then restrict the analysis to the standard case of a single cavity mode
interacting with a single mechanical resonator and we determine to what extent
optical absorption by the membrane hinder reaching a quantum regime for the
cavity-membrane system. We show that membrane absorption does not pose serious
limitations and that one can simultaneously achieve ground state cooling of a
vibrational mode of the membrane and stationary optomechanical entanglement
with state-of-the-art apparatuses.Comment: 14 pages, 7 figure
The inelastic Takahashi hard-rod gas
We study a one-dimensional fluid of hard-rods interacting each other via
binary inelastic collisions and a short ranged square-well potential. Upon
tuning the depth and the sign of the well, we investigate the interplay between
dissipation and cohesive or repulsive forces. Molecular dynamics simulations of
the cooling regime indicate that the presence of this simple interparticle
interaction is sufficient to significantly modify the energy dissipation rates
expected by the Haff's law for the free cooling. The simplicity of the model
makes it amenable to an analytical approach based on the Boltzmann-Enskog
transport equation which allows deriving the behaviour of the granular
temperature. Furthermore, in the elastic limit, the model can be solved exactly
to provide a full thermodynamic description. A meaningful theoretical
approximation explaining the properties of the inelastic system in interaction
with a thermal bath can be directly extrapolated from the properties of the
corresponding elastic system, upon a proper re-definition of the relevant
observables. Simulation results both in the cooling and driven regime can be
fairly interpreted according to our theoretical approach and compare rather
well to our predictions.Comment: 14 pages RevTex, 9 eps figure
Molecular dynamics simulations of reflection and adhesion behavior in Lennard-Jones cluster deposition
We conduct molecular dynamics simulations of the collision of atomic clusters
with a weakly-attractive surface. We focus on an intermediate regime, between
soft-landing and fragmentation, where the cluster undergoes deformation on
impact but remains largely intact, and will either adhere to the surface (and
possibly slide), or be reflected. We find that the outcome of the collision is
determined by the Weber number, We i.e. the ratio of the kinetic energy to the
adhesion energy, with a transition between adhesion and reflection occurring as
We passes through unity. We also identify two distinct collision regimes: in
one regime the collision is largely elastic and deformation of the cluster is
relatively small but in the second regime the deformation is large and the
adhesion energy starts to depend on the kinetic energy. If the transition
between these two regimes occurs at a similar kinetic energy to that of the
transition between reflection and adhesion, then we find that the probability
of adhesion for a cluster can be bimodal. In addition we investigate the
effects of the angle of incidence on adhesion and reflection. Finally we
compare our findings both with recent experimental results and with macroscopic
theories of particle collisions.Comment: 18 pages, 13 figure
A wireless platform for in vivo measurement of resistance properties of the gastrointestinal tract
Active locomotion of wireless capsule endoscopes has the potential to improve the diagnostic yield of this painless technique for the diagnosis of gastrointestinal tract disease. In order to design effective locomotion mechanisms, a quantitative measure of the propelling force required to effectively move a capsule inside the gastrointestinal tract is necessary. In this study, we introduce a novel wireless platform that is able to measure the force opposing capsule motion, without perturbing the physiologic conditions with physical connections to the outside of the gastrointestinal tract. The platform takes advantage of a wireless capsule that is magnetically coupled with an external permanent magnet. A secondary contribution of this manuscript is to present a real-time method to estimate the axial magnetic force acting on a wireless capsule manipulated by an external magnetic field. In addition to the intermagnetic force, the platform provides real-time measurements of the capsule position, velocity, and acceleration. The platform was assessed with benchtop trials within a workspace that extends 15 cm from each side of the external permanent magnet, showing average error in estimating the force and the position of less than 0.1 N and 10 mm, respectively. The platform was also able to estimate the dynamic behavior of a known resistant force with an error of 5.45%. Finally, an in vivo experiment on a porcine colon model validated the feasibility of measuring the resistant force in opposition to magnetic propulsion of a wireless capsule
Optomechanical sideband cooling of a thin membrane within a cavity
We present an experimental study of dynamical back-action cooling of the
fundamental vibrational mode of a thin semitransparent membrane placed within a
high-finesse optical cavity. We study how the radiation pressure interaction
modifies the mechanical response of the vibrational mode, and the experimental
results are in agreement with a Langevin equation description of the coupled
dynamics. The experiments are carried out in the resolved sideband regime, and
we have observed cooling by a factor 350 We have also observed the mechanical
frequency shift associated with the quadratic term in the expansion of the
cavity mode frequency versus the effective membrane position, which is
typically negligible in other cavity optomechanical devices.Comment: 15 pages, 7 figure
SMAC — A Modular Open Source Architecture for Medical Capsule Robots
The field of Medical Capsule Robots (MCRs) is gaining momentum in the robotics community, with applications spanning from abdominal surgery to gastrointestinal (GI) endoscopy. MCRs are miniature multifunctional devices usually constrained in both size and on-board power supply. The design process for MCRs is time consuming and resource intensive, as it involves the development of custom hardware and software components. In this work, we present the STORM Lab Modular Architecture for Capsules (SMAC), a modular open source architecture for MCRs aiming to provide the MCRs research community with a tool for shortening the design and development time for capsule robots. The SMAC platform consists of both hardware modules and firmware libraries that can be used for developing MCRs. In particular, the SMAC modules are miniature boards of uniform diameter (i.e., 9.8 mm) that are able to fulfill five different functions: signal coordination combined with wireless data transmission, sensing, actuation, powering and vision/illumination. They are small in size, low power, and have reconfigurable software libraries for the Hardware Abstraction Layer (HAL), which has been proven to work reliably for different types of MCRs. A design template for a generic SMAC application implementing a robust communication protocol is presented in this work, together with its finite state machine abstraction, capturing all the architectural components involved. The reliability of the wireless link is assessed for different levels of data transmission power and separation distances. The current consumption for each SMAC module is quantified and the timing of a SMAC radio message transmission is characterized. Finally, the applicability of SMAC in the field of MCRs is discussed by analysing examples from the literature
Closed-Loop Control of Local Magnetic Actuation for Robotic Surgical Instruments
We propose local magnetic actuation (LMA) as an approach to robotic actuation for surgical instruments. An LMA actuation unit consists of a pair of diametrically magnetized single-dipole cylindrical magnets, working as magnetic gears across the abdominal wall. In this study, we developed a dynamic model for an LMA actuation unit by extending the theory proposed for coaxial magnetic gears. The dynamic model was used for closed-loop control, and two alternative strategies-using either the angular velocity at the motor or at the load as feedback parameter-were compared. The amount of mechanical power that can be transferred across the abdominal wall at different intermagnetic distances was also investigated. The proposed dynamic model presented a relative error below 7.5% in estimating the load torque from the system parameters. Both the strategies proposed for closed-loop control were effective in regulating the load speed with a relative error below 2% of the desired steady-state value. However, the load-side closed-loop control approach was more precise and allowed the system to transmit larger values of torque, showing, at the same time, less dependence from the angular velocity. In particular, an average value of 1.5 mN·m can be transferred at 7 cm, increasing up to 13.5 mN·m as the separation distance is reduced down to 2 cm. Given the constraints in diameter and volume for a surgical instrument, the proposed approach allows for transferring a larger amount of mechanical power than what would be possible to achieve by embedding commercial dc motors
- …
