1,804 research outputs found
Review of the Laguerre-Gauss mode technology research program at Birmingham
Gravitational wave detectors from the advanced generation onwards are
expected to be limited in sensitivity by thermal noise of the optics, making
the reduction of this noise a key factor in the success of such detectors. A
proposed method for reducing the impact of this noise is to use higher-order
Laguerre-Gauss (LG) modes for the readout beam, as opposed to the currently
used fundamental mode. We present here a synopsis of the research program
undertaken by the University of Birmingham into the suitability of LG mode
technology for future gravitational wave detectors. This will cover our
previous and current work on this topic, from initial simulations and table-top
LG mode experiments up to implementation in a prototype scale suspended cavity
and high-power laser bench
Localization due to Damage in Two-Direction Fiber-Reinforced Composites
International audienceFiber pull-out is one of the fracture features of fiber-reinforced ceramic matrix composites. The onset of this mechanism is predicted by using continuum damage mechanics, and corresponds to a localization of deformation. After deriving two damage models from a uniaxial bundle approach, different configurations are analyzed through numerical methods. For one model some very simple criteria can be derived, whereas for the second one none of these criteria can be derived and the general criterion of localization must be used
DC-readout of a signal-recycled gravitational wave detector
All first-generation large-scale gravitational wave detectors are operated at
the dark fringe and use a heterodyne readout employing radio frequency (RF)
modulation-demodulation techniques. However, the experience in the currently
running interferometers reveals several problems connected with a heterodyne
readout, of which phase noise of the RF modulation is the most serious one. A
homodyne detection scheme (DC-readout), using the highly stabilized and
filtered carrier light as local oscillator for the readout, is considered to be
a favourable alternative. Recently a DC-readout scheme was implemented on the
GEO 600 detector. We describe the results of first measurements and give a
comparison of the performance achieved with homodyne and heterodyne readout.
The implications of the combined use of DC-readout and signal-recycling are
considered.Comment: 11 page
Photon pressure induced test mass deformation in gravitational-wave detectors
A widely used assumption within the gravitational-wave community has so far
been that a test mass acts like a rigid body for frequencies in the detection
band, i.e. for frequencies far below the first internal resonance. In this
article we demonstrate that localized forces, applied for example by a photon
pressure actuator, can result in a non-negligible elastic deformation of the
test masses. For a photon pressure actuator setup used in the gravitational
wave detector GEO600 we measured that this effect modifies the standard
response function by 10% at 1 kHz and about 100% at 2.5 kHz
Triple Michelson Interferometer for a Third-Generation Gravitational Wave Detector
The upcoming European design study `Einstein gravitational-wave Telescope'
represents the first step towards a substantial, international effort for the
design of a third-generation interferometric gravitational wave detector. It is
generally believed that third-generation instruments might not be installed
into existing infrastructures but will provoke a new search for optimal
detector sites. Consequently, the detector design could be subject to fewer
constraints than the on-going design of the second generation instruments. In
particular, it will be prudent to investigate alternatives to the traditional
L-shaped Michelson interferometer. In this article, we review an old proposal
to use three Michelson interferometers in a triangular configuration. We use
this example of a triple Michelson interferometer to clarify the terminology
and will put this idea into the context of more recent research on
interferometer technologies. Furthermore the benefits of a triangular detector
will be used to motivate this design as a good starting point for a more
detailed research effort towards a third-generation gravitational wave
detector.Comment: Minor corrections to the main text and two additional appendices. 14
pages, 6 figure
Optimal time-domain combination of the two calibrated output quadratures of GEO 600
GEO 600 is an interferometric gravitational wave detector with a 600 m arm-length and which uses a dual-recycled optical configuration to give enhanced sensitivity over certain frequencies in the detection band. Due to the dual-recycling, GEO 600 has two main output signals, both of which potentially contain gravitational wave signals. These two outputs are calibrated to strain using a time-domain method. In order to simplify the analysis of the GEO 600 data set, it is desirable to combine these two calibrated outputs to form a single strain signal that has optimal signal-to-noise ratio across the detection band. This paper describes a time-domain method for doing this combination. The method presented is similar to one developed for optimally combining the outputs of two colocated gravitational wave detectors. In the scheme presented in this paper, some simplifications are made to allow its implementation using time-domain methods
Impact of alloy disorder on the band structure of compressively strained GaBiAs
The incorporation of bismuth (Bi) in GaAs results in a large reduction of the
band gap energy (E) accompanied with a large increase in the spin-orbit
splitting energy (), leading to the condition that
which is anticipated to reduce so-called CHSH Auger
recombination losses whereby the energy and momentum of a recombining
electron-hole pair is given to a second hole which is excited into the
spin-orbit band. We theoretically investigate the electronic structure of
experimentally grown GaBiAs samples on (100) GaAs substrates by
directly comparing our data with room temperature photo-modulated reflectance
(PR) measurements. Our atomistic theoretical calculations, in agreement with
the PR measurements, confirm that E is equal to for
9. We then theoretically probe the inhomogeneous
broadening of the interband transition energies as a function of the alloy
disorder. The broadening associated with spin-split-off transitions arises from
conventional alloy effects, while the behaviour of the heavy-hole transitions
can be well described using a valence band-anticrossing model. We show that for
the samples containing 8.5% and 10.4% Bi the difficulty in identifying a clear
light-hole-related transition energy from the measured PR data is due to the
significant broadening of the host matrix light-hole states as a result of the
presence of a large number of Bi resonant states in the same energy range and
disorder in the alloy. We further provide quantitative estimates of the impact
of supercell size and the assumed random distribution of Bi atoms on the
interband transition energies in GaBiAs. Our calculations support
a type-I band alignment at the GaBiAs/GaAs interface, consistent
with recent experimental findings
Reducing Thermal Noise in Future Gravitational Wave Detectors by employing Khalili Etalons
Reduction of thermal noise in dielectric mirror coatings is a key issue for
the sensitivity improvement in second and third generation interferometric
gravitational wave detectors. Replacing an end mirror of the interferometer by
an anti-resonant cavity (a so-called Khalili cavity) has been proposed to
realize the reduction of the overall thermal noise level. In this article we
show that the use of a Khalili etalon, which requires less hardware than a
Khalili cavity, yields still a significant reduction of thermal noise. We
identify the optimum distribution of coating layers on the front and rear
surfaces of the etalon and compare the total noise budget with a conventional
mirror. In addition we briefly discuss advantages and disadvantages of the
Khalili etalon compared with the Khalili cavity in terms of technical aspects,
such as interferometric length control and thermal lensing.Comment: 13 pages, 9 figure
Microelectromechanical system gravimeters as a new tool for gravity imaging
A microelectromechanical system (MEMS) gravimeter has been manufactured with a sensitivity of 40 ppb in an integration time of 1 s. This sensor has been used to measure the Earth tides: the elastic deformation of the globe due to tidal forces. No such measurement has been demonstrated before now with a MEMS gravimeter. Since this measurement, the gravimeter has been miniaturized and tested in the field. Measurements of the free-air and Bouguer effects have been demonstrated by monitoring the change in gravitational acceleration measured while going up and down a lift shaft of 20.7 m, and up and down a local hill of 275 m. These tests demonstrate that the device has the potential to be a useful field-portable instrument. The development of an even smaller device is underway, with a total package size similar to that of a smartphone
A statistical veto method employing an amplitude consistency check
Statistical veto methods are commonly used to reduce the list of candidate gravitational wave (GW) events which are detected as transient (burst) signals in the main output of GW detectors. If a burst event in the GW channel is coincident with an event in a veto channel (where the veto channel does not contain any GW signal), it is possible to veto the event from the GW channel with a low 'false-veto' rate. Unfortunately, many promising veto channels are interferometer channels which can, at some level, contain traces of any detected GW signal. In this case, the application of a 'standard statistical veto' could have a high false-veto rate. We will present an extension to the standard statistical veto method that includes an 'amplitude consistency check'. This method allows the application of statistical vetoes derived from interferometer channels containing GW information with a low false-veto rate. By applying a statistical veto with an amplitude consistency check to data from the GEO 600 detector, veto efficiencies between 5 and 20%, together with a use-percentage of up to 80%, were obtained. The robustness of this veto method was also confirmed by hardware injections. The burst triggers were generated using the mHACR detection algorithm
- …