7,319 research outputs found

    David Hume's Reductionist Epistemology of Testimony

    Get PDF
    David Hume advances a reductionist epistemology of testimony: testimonial beliefs are justified on the basis of beliefs formed from other sources. This reduction, however, has been misunderstood. Testimonial beliefs are not justified in a manner identical to ordinary empirical beliefs; it is true, they are justified by observation of the conjunction between testimony and its truth, but the nature of the conjunctions has been misunderstood. The observation of these conjunctions provides us with our knowledge of human nature and it is this knowledge which justifies our testimonial beliefs. Hume gives a naturalistic rather than a sceptical account of testimony

    On the Rationality of our Response to Testimony

    Get PDF
    The assumption that we largely lack reasons for accepting testimony has dominated its epistemology. Given the further assumption that whatever reasons we do have are insufficient to justify our testimonial beliefs, many conclude that any account of testimonial knowledge must allow credulity to be justified. In this paper I argue that both of these assumptions are false. Our responses to testimony are guided by our background beliefs as to the testimony as a type, the testimonial situation, the testifier''s character and the truth of the proposition testified to. These beliefs provide reasons for our responses. Thus, we usually do have reasons, in the sense of propositions believed, for accepting testimony and these reasons can provide evidence for the testimonial beliefs we form

    Device prepares aluminum surfaces for welding

    Get PDF
    Dry machining technique removes original surfaces to obtain contamination free welding surface. Device straddles edge being prepared and aligns with existing edges and adjacent surfaces of workpiece while sensing device regulates cut depth. Description of prototype is given

    Discriminating coastal rangeland production and improvements with computer aided techniques

    Get PDF
    The feasibility and utility of using satellite data and computer-aided remote sensing analysis techniques to conduct range inventories were tested. This pilot study was focused over a 250,000 acre site in Galveston and Brazoria Counties along the Texas Gulf Coast. Rectified enlarged aircraft color infrared photographs of this site were used as the ground truth base. The different land categories were identified, delineated, and measured. Multispectral scanner (MSS) bulk data from LANDSAT-1 was received and analyzed with the Image 100 pattern recognition system. Features of interest were delineated on the image console giving the number of picture elements classified; the picture elements were converted to acreages and the accuracy of the technique was evaluated by comparison with data base results for three test sites. The accuracies for computer aided classification of coastal marshes ranged from 89% to 96%

    First Year Projects and Activities of the Environmental Remote Sensing Applications Laboratory (ERSAL)

    Get PDF
    Activities, pilot projects, and research that will effectively close the gap between state-of-the-art remote sensing technology and the potential users and beneficiaries of this technological and scientific progress are discussed in light of the first year of activity. A broad spectrum of resource and man-environment problems are described in terms of the central thrust of the first-year program to support land use planning decisions with information derived from the interpretation of NASA highlight and satellite imagery

    Could posterior-anterior projection cervical spine radiographs improve image quality and dose reduction

    Get PDF
    Introduction: Anterior-posterior (AP) cervical spine X-rays are routine examinations to assess degenerative change, persistent pain and traumatic injuries. Multiple radiosensitive organs lie anteriorly within this anatomical region, increasing the stochastic risk of cancer. If a posterior-anterior (PA) projection was utilised, the radiation dose could potentially be reduced. The hypothesis of this study is to evaluate the change in radiation dose and image quality between AP and PA positions. Materials and Methods: An anthropomorphic phantom was positioned AP erect against a digital radiography (DR) detector with 30 thermoluminescent dosimeters (TLDs) inserted to record the thyroid, breast, ovaries, and testes absorbed radiation dose at an exposure of 66 kV and 8 mAs. The phantom was repositioned PA erect and repeated. Images were assessed against an image quality criteria Likert scale by qualified radiographers. The mean and standard deviations were calculated for dose and image quality and compared using a t-test and Wilcoxon Signed Ranks Test. Results: The PA erect cervical spine reduced radiation dose to the right thyroid by 92% (44.7 µGy; p=0.00) and the left thyroid by 89% (43.7 µGy; p=0.00), with further reductions in scatter dose to the breasts (0.35-0.45 µGy; p=0.85), ovaries (0.41 µGy; p=0.57), and testes (0.04 µGy; p=0.98). Image quality scores for the end plates, pedicles, joint spaces, spinous and transverse processes, cortical and trabecular bone patterns, and soft tissues were near equivalent (p=0.32). Conclusion: Data analysis suggests that PA cervical spine positioning for X-rays in the laboratory adheres to as low as reasonably practicable (ALARP) guidance on X-ray examinations to reduce radiation dose to male and female internal organs (thyroid, breast, ovaries) without a reduction in image quality compared to AP positioning. Further research in clinical practice is advised

    Contributions of temporal encodings of voicing, voicelessness, fundamental frequency, and amplitude variation to audiovisual and auditory speech perception

    Get PDF
    Auditory and audio-visual speech perception was investigated using auditory signals of invariant spectral envelope that temporally encoded the presence of voiced and voiceless excitation, variations in amplitude envelope and F-0. In experiment 1, the contribution of the timing of voicing was compared in consonant identification to the additional effects of variations in F-0 and the amplitude of voiced speech. In audio-visual conditions only, amplitude variation slightly increased accuracy globally and for manner features. F-0 variation slightly increased overall accuracy and manner perception in auditory and audio-visual conditions. Experiment 2 examined consonant information derived from the presence and amplitude variation of voiceless speech in addition to that from voicing, F-0, and voiced speech amplitude. Binary indication of voiceless excitation improved accuracy overall and for voicing and manner. The amplitude variation of voiceless speech produced only a small increment in place of articulation scores. A final experiment examined audio-visual sentence perception using encodings of voiceless excitation and amplitude variation added to a signal representing voicing and F-0. There was a contribution of amplitude variation to sentence perception, but not of voiceless excitation. The timing of voiced and voiceless excitation appears to be the major temporal cues to consonant identity. (C) 1999 Acoustical Society of America. [S0001-4966(99)01410-1]

    The Courtesy Copy Trap: Untimely Removal from State to Federal Court

    Get PDF
    corecore