8 research outputs found

    Measurement of absolute γ-ray emission probabilities in the decay of 227Ac in equilibrium with its progeny

    Get PDF
    Abstract The emission probabilities of γ rays produced in the 227Ac decay series were determined by high-resolution γ-ray spectrometry of sources with standardised activity. The sources were prepared quantitatively on glass discs by drop deposition of a solution with 227Ac in radioactive equilibrium with its daughter nuclides. Their activity was measured by a primary standardisation technique based on alpha-particle counting at a defined low solid angle. Four laboratories performed γ-ray spectrometry and derived absolute γ-ray intensities. Mean values were calculated and compared with literature data and the currently recommended evaluated data. New values on certain γ-ray emission probabilities are proposed

    measurement of absolute γ ray emission probabilities in the decay of 235u

    Get PDF
    Abstract Accurate measurements were performed of the photon emission probabilities following the α decay of 235U to 231Th. Sources of highly enriched 235U were characterised in terms of isotopic composition by mass spectrometry and their activities were standardised by means of alpha-particle counting at a low defined solid angle. The standardised sources were subsequently measured by high-resolution γ-ray spectrometry with calibrated high-purity germanium detectors to determine the photon emission probabilities. Four laboratories participated in this work and reported emission probabilities for 33 γ-ray lines. Most of them agree with previously published evaluated data. In addition, new values are proposed for γ-lines which have been measured only once in the past

    The worldwide NORM production and a fully automated gamma-ray spectrometer for their characterization

    Get PDF
    Materials containing radionuclides of natural origin, which is modified by human made processes and being subject to regulation because of their radioactivity are known as NORM. We present a brief review of the main categories of non-nuclear industries together with the levels of activity concentration in feed raw materials, products and waste, including mechanisms of radioisotope enrichments. The global management of NORM shows a high level of complexity, mainly due to different degrees of radioactivity enhancement and the huge amount of worldwide waste production. The future tendency of guidelines concerning environmental protection will require both a systematic monitoring based on the ever-increasing sampling and high performance of gamma ray spectroscopy. On the ground of these requirements a new low background fully automated high-resolution gamma-ray spectrometer MCA_Rad has been developed. The design of Pb and Cu shielding allowed to reach a background reduction of two order of magnitude with respect to laboratory radioactivity. A severe lowering of manpower cost is obtained through a fully automation system, which enables up to 24 samples to be measured without any human attendance. Two coupled HPGe detectors increase the detection efficiency, performing accurate measurements on sample volume (180 cc) with a reduction of sample transport cost of material. Details of the instrument calibration method are presented. MCA_Rad system can measure in less than one hour a typical NORM sample enriched in U and Th with some hundreds of Bq/kg, with an overall uncertainty less than 5%. Quality control of this method has been tested. Measurements of certified reference materials RGK-1, RGU-2 and RGTh-1 containing concentrations of K, U and Th comparable to NORM have been performed, resulting an overall relative discrepancy of 5% among central values within the reported uncertainty.Comment: 21 pages, 4 figures, 6 table

    Activity measurements and determination of nuclear decay data of 166^{166}Ho in the MRTDosimetry project

    No full text
    International audienceHolmium-166 is a high-energy β^−-emitter radionuclide (~ 1.8 MeV) with a short half-life that offers great potential as an alternative to 90Y for the treatment of liver cancer based on radioembolization. The possibility of quantitative Single Photon Emission Computed Tomography (SPECT) imaging of the main γ-ray emission at 80.6 keV, in addition to strong paramagnetic properties suitable for Magnetic Resonance Imaging (MRI), complement this therapeutic potential. The present paper describes the measurements carried out in three European radionuclide metrology laboratories for primary standardization of 166Ho and new determinations of X- and γ-ray photon-emission intensities in the framework of the European EMPIR project MRTDosimetry. New half-life measurements were also performed

    Measurement of absolute γ-ray emission probabilities in the decay of 235 U

    Get PDF
    Abstract Accurate measurements were performed of the photon emission probabilities following the α decay of 235U to 231Th. Sources of highly enriched 235U were characterised in terms of isotopic composition by mass spectrometry and their activities were standardised by means of alpha-particle counting at a low defined solid angle. The standardised sources were subsequently measured by high-resolution γ-ray spectrometry with calibrated high-purity germanium detectors to determine the photon emission probabilities. Four laboratories participated in this work and reported emission probabilities for 33 γ-ray lines. Most of them agree with previously published evaluated data. In addition, new values are proposed for γ-lines which have been measured only once in the past

    International exercise on 124Sb activity measurements.

    No full text
    An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories. In order to identify possible biases, the participants were asked to use all possible activity measurement methods available in their laboratory and then to determine their reference value for comparison. Thus, measurement results from 4pibeta-gamma coincidence/anti-coincidence counting, CIEMAT/NIST liquid-scintillation counting, 4pigamma counting with well-type ionization chambers and well-type crystal detectors were given. The results are compared and show a maximum discrepancy of about 1.6%: possible explanations are proposed
    corecore