618 research outputs found
A short-duration dark adaptation protocol for assessment of age-related maculopathy
Dark adaptometry may be a useful diagnostic test and clinical trial endpoint for age-related maculopathy (ARM) because impaired night vision is a hallmark of early ARM. A novel dark adaptometer, the AdaptDx, was evaluated for the detection of ARM. The AdaptDx incorporates a 20-minute protocol optimized for the detection of ARM. ARM patients (N = 17) exhibited substantial dark adaptation impairment compared with normal adults (N = 17). The diagnostic sensitivity was 88% and the specificity was 100%. The diagnostic test characteristics of the AdaptDx are similar to previously reported studies using 60- to 120-minute protocols
American Geriatrics Society and National Institute on Aging Bench-to-Bedside conference: sensory impairment and cognitive decline in older adults
This article summarizes the presentations and recommendations of the tenth annual American Geriatrics Society and National Institute on Aging Bench‐to‐Bedside research conference, “Sensory Impairment and Cognitive Decline,” on October 2–3, 2017, in Bethesda, Maryland. The risk of impairment in hearing, vision, and other senses increases with age, and almost 15% of individuals aged 70 and older have dementia. As the number of older adults increases, sensory and cognitive impairments will affect a growing proportion of the population. To limit its scope, this conference focused on sensory impairments affecting vision and hearing. Comorbid vision, hearing, and cognitive impairments in older adults are more common than would be expected by chance alone, suggesting that some common mechanisms might affect these neurological systems. This workshop explored the mechanisms and consequences of comorbid vision, hearing, and cognitive impairment in older adults; effects of sensory loss on the aging brain; and bench‐to‐bedside innovations and research opportunities. Presenters and participants identified many research gaps and questions; the top priorities fell into 3 themes: mechanisms, measurement, and interventions. The workshop delineated specific research questions that provide opportunities to improve outcomes in this growing population.Funding was provided by National Institutes of Health (NIH) Grant U13 AG054139-01. Dr. Whitson's efforts and contributions were supported by R01AG043438, R24AG045050, UH2AG056925, and 5P30AG028716. Dr. Lin's effort and contributions were also supported by R01AG055426, R01HL096812, and R33DC015062. (U13 AG054139-01 - National Institutes of Health (NIH); R01AG043438; R24AG045050; UH2AG056925; 5P30AG028716; R01AG055426; R01HL096812; R33DC015062)Accepted manuscrip
Photoreceptor perturbation around subretinal drusenoid deposits as revealed by adaptive optics scanning laser ophthalmoscopy
PURPOSE: To describe the microscopic structure of photoreceptors impacted by subretinal drusenoid deposits, also called pseudodrusen, an extracellular lesion associated with age-related macular degeneration (AMD), using adaptive optics scanning laser ophthalmoscopy (AOSLO). DESIGN: Observational case series. METHODS: We recruited 53 patients with AMD and 10 age-similar subjects who had normal retinal health. All subjects underwent color fundus photography, infrared reflectance, red-free reflectance, autofluorescence, and spectral-domain optical coherence tomography (OCT). Subretinal drusenoid deposits were classified by a 3-stage OCT-based grading system. Lesions and surrounding photoreceptors were examined by AOSLO. RESULTS: Subretinal drusenoid deposits were found in 26 eyes of 13 patients with AMD and imaged by AOSLO and spectral-domain OCT in 18 eyes (n = 342 lesions). Spectral-domain OCT showed subretinal drusenoid deposits as highly reflective material accumulated internal to the retinal pigment epithelium. AOSLO revealed that photoreceptor reflectivity was qualitatively reduced by stage 1 subretinal drusenoid deposits and was greatly reduced by stage 2. AOSLO presented a distinct structure in stage 3, a hyporeflective annulus consisting of deflected, degenerated or absent photoreceptors. A central core with a reflectivity superficially resembling photoreceptors is formed by the lesion material itself. A hyporeflective gap in the photoreceptor ellipsoid zone on either side of this core shown in spectral-domain OCT corresponded to the hyporeflective annulus seen by AOSLO. CONCLUSIONS: AOSLO and multimodal imaging of subretinal drusenoid deposits indicate solid, space-filling lesions in the subretinal space. Associated retinal reflectivity changes are related to lesion stages and are consistent with perturbations to photoreceptors, as suggested by histology
Recommended from our members
The effect of bleach duration and age on the ERG photostress test
Background: The ERG photostress test assesses the recovery of the focal 41 Hz ERG following exposure to a bright light that bleaches a significant proportion of photopigment. The aims of this study were: 1) to compare the repeatability of the ERG photostress test recovery time constant following long and short duration light exposure, and 2) to determine the effect of age on the ERG photostress test recovery time constant.
Methods: Focal 41 Hz ERGs were recorded from 23 participants (age range 20–71 years) at 20-second intervals for 5 minutes following either a short-duration (photoflash) or long-duration (equilibrium) light exposure. After a 5-minute wash-out period, the procedure was repeated using the second bleach modality. The time constant of cone recovery was determined by fitting an exponential model to the amplitude recovery data. The whole procedure was repeated on a second occasion. The co-efficient of repeatability (CoR) was calculated for each bleaching technique. The relationship between the time constant of recovery and age was investigated (Pearson’s correlation coefficient).
Results: The time constant of recovery following an equilibrium bleach was more repeatable than recovery following a photoflash (CoR = 85s and 184s respectively). Eight trials (from seven participants) failed to show a reduction in amplitude following the photoflash, suggesting that a blink or fixation loss had occurred. All participants were reliably light-adapted by the equilibrium bleach. For the equilibrium bleach data, the time constant of recovery increased with age at a rate of 27 seconds per decade.
Conclusions: The equilibrium bleach was more reliable and repeatable than the photoflash. Increasing participant age was shown to result in a lengthening of the recovery time constant, of a magnitude comparable to previously published psychophysical data
DCE Bio Detection System Final Report
The DCE (DNA Capture Element) Bio-Detection System (Biohound) was conceived, designed, built and tested by PNNL under a MIPR for the US Air Force under the technical direction of Dr. Johnathan Kiel and his team at Brooks City Base in San Antonio Texas. The project was directed toward building a measurement device to take advantage of a unique aptamer based assay developed by the Air Force for detecting biological agents. The assay uses narrow band quantum dots fluorophores, high efficiency fluorescence quenchers, magnetic micro-beads beads and selected aptamers to perform high specificity, high sensitivity detection of targeted biological materials in minutes. This final report summarizes and documents the final configuration of the system delivered to the Air Force in December 200
First and second eye cataract surgery and driver self-regulation among older drivers with bilateral cataract: A prospective cohort study
Background: Driving a car is the most common form of transport among the older population. Common medical conditions such as cataract, increase with age and impact on the ability to drive. To compensate for visual decline, some cataract patients may self-regulate their driving while waiting for cataract surgery. However, little is known about the self-regulation practices of older drivers throughout the cataract surgery process. The aim of this study is to assess the impact of first and second eye cataract surgery on driver self-regulation practices, and to determine which objective measures of vision are associated with driver self-regulation. Methods: Fifty-five older drivers with bilateral cataract aged 55+ years were assessed using the self-reported Driving Habits Questionnaire, the Mini-Mental State Examination and three objective visual measures in the month before cataract surgery, at least one to three months after first eye cataract surgery and at least one month after second eye cataract surgery. Participants' natural driving behaviour in four driving situations was also examined for one week using an in-vehicle monitoring device. Two separate Generalised Estimating Equation logistic models were undertaken to assess the impact of first and second eye cataract surgery on driver-self-regulation status and which changes in visual measures were associated with driver self-regulation status. Results: The odds of being a self-regulator in at least one driving situation significantly decreased by 70% after first eye cataract surgery (OR: 0.3, 95% CI: 0.1-0.7) and by 90% after second eye surgery (OR: 0.1, 95% CI: 0.1-0.4), compared to before first eye surgery. Improvement in contrast sensitivity after cataract surgery was significantly associated with decreased odds of self-regulation (OR: 0.02, 95% CI: 0.01-0.4). Conclusions: The findings provide a strong rationale for providing timely first and second eye cataract surgery for older drivers with bilateral cataract, in order to improve their mobility and independence
Age-related decline of peripheral visual processing: the role of eye movements
Earlier work suggests that the area of space from which useful visual information can be extracted (useful field of view, UFoV) shrinks in old age. We investigated whether this shrinkage, documented previously with a visual search task, extends to a bimanual tracking task. Young and elderly subjects executed two concurrent tracking tasks with their right and left arms. The separation between tracking displays varied from 3 to 35 cm. Subjects were asked to fixate straight ahead (condition FIX) or were free to move their eyes (condition FREE). Eye position was registered. In FREE, young subjects tracked equally well at all display separations. Elderly subjects produced higher tracking errors, and the difference between age groups increased with display separation. Eye movements were comparable across age groups. In FIX, elderly and young subjects tracked less well at large display separations. Seniors again produced higher tracking errors in FIX, but the difference between age groups did not increase reliably with display separation. However, older subjects produced a substantial number of illicit saccades, and when the effect of those saccades was factored out, the difference between young and older subjects’ tracking did increase significantly with display separation in FIX. We conclude that the age-related shrinkage of UFoV, previously documented with a visual search task, is observable with a manual tracking task as well. Older subjects seem to partly compensate their deficit by illicit saccades. Since the deficit is similar in both conditions, it may be located downstream from the convergence of retinal and oculomotor signals
Large Scale Climate Oscillation Impacts on Temperature, Precipitation and Land Surface Phenology in Central Asia
Central Asia has been rapidly changing in multiple ways over the past few decades. Increases in temperature and likely decreases in precipitation in Central Asia as the result of global climate change are making one of the most arid regions in the world even more susceptible to large-scale droughts. Global climate oscillations, such as the El Ni ̃no–Southern Oscillation, have previously been linked to observed weather patterns in Central Asia. However, until now it has been unclear how the different climate oscillations act simultaneously to affect the weather and subsequently the vegetated land surface in Central Asia.We fit well-established land surface phenology models to two versions of MODIS data to identify the land surface phenology of Central Asia between 2001 and 2016. We then combine five climate oscillation indices into one regression model and identify the relative importance of each of these indices on precipitation, temperature, and land surface phenology, to learn where each climate index has the strongest influence. Our analyses illustrate that the North Atlantic Oscillation, the East Atlantic/West Russia pattern, and the AtlanticMulti-Decadal Oscillation predominantly influence temperature in the northern part of Central Asia.We also show that the Scandinavia index and the Multivariate ENSO index both reveal significant impacts on the precipitation in this region. Thus, we conclude that the land surface phenology across Central Asia is affected by several climate modes, both those that are strongly linked to far northern weather patterns and those that are forced by southern weather patterns, making this region a \u27climate change hotspot’ with strong spatial variations in weather patterns.We also show that regional climate patterns play a significant role in Central Asia, indicating that global climate patterns alone might not be sufficient to project weather patterns and subsequent land surface changes in this region
Driver self-regulation and depressive symptoms in cataract patients awaiting surgery: a cross-sectional study
Background: Cataract is an extremely common visual condition of ageing. Evidence suggests that visual impairment influences driving patterns and self-regulatory behavior among older drivers. However, little is known about the psychological effects of driver self-regulation among older drivers. Therefore, this study aimed to describe driver self-regulation practices among older bilateral cataract patients and to determine the association between self-regulation and depressive symptoms. Methods: Ninety-nine older drivers with bilateral cataract were assessed the week before first eye cataract surgery. Driver self-regulation was measured via the Driving Habits Questionnaire. Depressive symptoms were assessed using the 20-item Center for Epidemiological Studies Depression Scale. Visual, demographic and cognitive data were also collected. Differences between self-regulators and non self-regulators were described and linear regression modeling used to determine the association between driver self-regulation and depressive symptoms score. Results: Among cataract patients, 48% reported self-regulating their driving to avoid at least one challenging situation. The situations most commonly avoided were driving at night (40%), on the freeway (12%), in the rain (9%) and parallel parking (8%). Self-regulators had significantly poorer contrast sensitivity in their worse eye than non self-regulators (p = 0.027). Driver self-regulation was significantly associated with increased depressive symptoms after controlling for potential confounding factors (p = 0.002).Conclusions: Driver self-regulation was associated with increased depressive symptoms among cataract patients. Further research should investigate this association among the general older population. Self-regulation programs aimed at older drivers may need to incorporate mental health elements to counteract unintended psychological effects
Model validation for a noninvasive arterial stenosis detection problem
Copyright @ 2013 American Institute of Mathematical SciencesA current thrust in medical research is the development of a non-invasive method for detection, localization, and characterization of an arterial stenosis (a blockage or partial blockage in an artery). A method has been proposed to detect shear waves in the chest cavity which have been generated by disturbances in the blood flow resulting from a stenosis. In order to develop this methodology further, we use both one-dimensional pressure and shear wave experimental data from novel acoustic phantoms to validate corresponding viscoelastic mathematical models, which were developed in a concept paper [8] and refined herein. We estimate model parameters which give a good fit (in a sense to be precisely defined) to the experimental data, and use asymptotic error theory to provide confidence intervals for parameter estimates. Finally, since a robust error model is necessary for accurate parameter estimates and confidence analysis, we include a comparison of absolute and relative models for measurement error.The National Institute of Allergy and Infectious Diseases, the Air Force Office of Scientific Research, the Deopartment of Education and the Engineering and Physical Sciences Research Council (EPSRC)
- …