28 research outputs found

    Usefulness of the Hybrid RFR-FFR Approach: Results of a Prospective and Multicenter Analysis of Diagnostic Agreement between RFR and FFR—The RECOPA (REsting Full-Cycle Ratio Comparation versus Fractional Flow Reserve (A Prospective Validation)) Study

    Get PDF
    Cardiologia; Estudi fisiolĂČgic; EspanyaCardiologĂ­a; Estudio fisiolĂłgico; EspañaCardiology; Physiological study; SpainBackground. The resting full‐cycle ratio (RFR) is a novel resting index which in contrast to the gold standard (fractional flow reserve (FFR)) does not require maximum hyperemia induction. The objectives of this study were to evaluate the agreement between RFR and FFR with the currently recommended thresholds and to design a hybrid RFR-FFR ischemia detection strategy, allowing a reduction of coronary vasodilator use. Materials and Methods. Patients subjected to invasive physiological study in 9 Spanish centers were prospectively recruited between April 2019 and March 2020. Sensitivity and specificity studies were made to assess diagnostic accuracy between the recommended levels of RFR ≀0.89 and FFR ≀0.80 (primary objective) and to determine the RFR “grey zone” in order to define a hybrid strategy with FFR affording 95% global agreement compared with FFR alone (secondary objective). Results. A total of 380 lesions were evaluated in 311 patients. Significant correlation was observed (R2 = 0.81; ) between the two techniques, with 79% agreement between RFR ≀ 0.89 and FFR ≀ 0.80 (positive predictive value, 68%, and negative predictive value, 80%). The hybrid RFR-FFR strategy, administering only adenosine in the “grey zone” (RFR: 0.86 to 0.92), exhibited an agreement of over 95% with FFR, with high predictive values (positive predictive value, 91%, and negative predictive value, 92%), reducing the need for vasodilators by 58%. Conclusions. Dichotomous agreement between RFR and FFR with the recommended thresholds is significant but limited. The adoption of a hybrid RFR-FFR strategy affords very high agreement, with minimization of vasodilator use

    Coronary Endothelium‐Dependent Vasomotor Function After Drug‐Eluting Stent and Bioresorbable Scaffold Implantation

    Get PDF
    Infarto de miocardio; DisfunciĂłn endotelial; TomografĂ­a de coherencia ĂłpticaMyocardial infarction; Endothelial dysfunction; Optical coherence tomographyInfart de miocardi; DisfunciĂł endotelial; Tomografia de coherĂšncia ĂČpticaBackground Early generation drug‐eluting stents (DESs) showed a high grade of coronary endothelial dysfunction that was attributed to lack of stent reendothelialization. Endothelium‐dependent vasomotor response of current DESs and bioresorbable scaffolds (BRSs) remains unknown. This study sought to assess the device‐related endothelial function of current devices and to correlate neointima healing with endothelial function. Methods and Results A total of 206 patients from 4 randomized trials treated with the durable‐polymer everolimus‐eluting Xience (n=44), bioresorbable‐polymer sirolimus‐eluting Orsiro (n=35), polymer‐free biolimus‐eluting Biofreedom (n=24), bioactive endothelial‐progenitor cell‐capturing sirolimus‐eluting Combo DES (n=25), polymer‐based everolimus‐eluting Absorb (n=44), and Mg‐based sirolimus‐eluting Magmaris BRS (n=34) underwent endothelium‐dependent vasomotor tests and optical coherence tomography imaging, as per protocol, at follow‐up. Crude vasomotor responses of distal segments to low‐dose acetylcholine (10−6 mol/L) were different between groups: bioresorbablepolymer DEShad the worst (−8.4%±12.6%) and durable‐polymer DES had the most physiologic (−0.4%±11.8%; P=0.014). High‐dose acetylcholine (10−4 mol/L) showed similar responses between groups (ranging from −10.8%±11.6% to −18.1%±15.4%; P=0.229). Device healing was different between devices. Uncovered struts ranged from 6.3%±7.1% (bioresorbable‐polymer DES) to 2.5%±4.5% (bioactive DES; P=0.056). In multivariate models, endothelium‐dependent vasomotor response was associated with age, bioresorbable‐polymer DES, and angiographic lumen loss, but not with strut coverage nor plaque type. Endothelial dysfunction (defined as ≄4% vasoconstriction) was observed in 46.6% of patients with low‐dose and 68.9% with high‐dose acetylcholine, without differences between groups. Conclusions At follow‐up, endothelial dysfunction was frequently observed in distal segments treated with current stents without remarkable differences between devices. Although neointima healing was different between devices, poor healing was not associated with endothelial dysfunction.The source funding of the 4 randomized trials included in this study is the following. The BVS‐FLOW trial (Coronary vasomotor function and myocardial flow with bioresorbable vascular scaffolds or everolimus‐eluting metallic stents: a randomised trial) was funded by a grant of “La Marato” Foundation. The Spanish Heart Foundation funded the RE‐TROFI2 (Long‐Term Coronary Functional Assessment of the Infarct‐Related Artery Treated With Everolimus‐Eluting Bioresorbable Scaffolds or Everolimus‐Eluting Metallic Stents: Insights of the TROFI II Trial) and MAGSTEMI (Magnesium‐Based Resorbable Scaffold Versus Permanent Metallic Sirolimus‐Eluting Stent in Patients With ST‐Segment Elevation Myocardial Infarction) trials. The FUNCOMBO (Coronary endothelial and microvascular function distal to polymer‐free and endothelial cell‐capturing drug‐eluting stents) trial was funded by OrbusNeich and was promoted by the Spanish Heart Foundation

    Ajustando RFR por Preditores de Discordñncia, “The Adjusted RFR”: Uma Metodologia Alternativa para Melhorar a Capacidade Diagnóstica de Índices Coronarianos

    Get PDF
    Background: Cutoff thresholds for the "resting full-cycle ratio" (RFR) oscillate in different series, suggesting that population characteristics may influence them. Likewise, predictors of discordance between the RFR and fractional flow reserve (FFR) have been documented. The RECOPA Study showed that diagnostic capacity is reduced in the RFR "grey zone", requiring the performance of FFR to rule out or confirm ischemia. Objectives: To determine predictors of discordance, integrate the information they provide in a clinical-physiological index, the "Adjusted RFR", and compare its agreement with the FFR. Methods: Using data from the RECOPA Study, predictors of discordance with respect to FFR were determined in the RFR "grey zone" (0.86 to 0.92) to construct an index ("Adjusted RFR") that would weigh RFR together with predictors of discordance and evaluate its agreement with FFR. Results: A total of 156 lesions were evaluated in 141 patients. Predictors of discordance were: chronic kidney disease, previous ischemic heart disease, lesions not involving the anterior descending artery, and acute coronary syndrome. Though limited, the "Adjusted RFR" improved the diagnostic capacity compared to the RFR in the "grey zone" (AUC-RFR = 0.651 versus AUC-"Adjusted RFR" = 0.749), also showing an improvement in all diagnostic indices when optimal cutoff thresholds were established (sensitivity: 59% to 68%; specificity: 62% to 75%; diagnostic accuracy: 60% to 71%; positive likelihood ratio: 1.51 to 2.34; negative likelihood ratio: 0.64 to 0.37). Conclusions: Adjusting the RFR by integrating the information provided by predictors of discordance to obtain the "Adjusted RFR" improved the diagnostic capacity in our population. Further studies are required to evaluate whether clinical-physiological indices improve the diagnostic capacity of RFR or other coronary indices.Fundamento: Os limiares de corte para a “relação do ciclo completo de repouso” (RFR) oscilam em diferentes sĂ©ries, sugerindo que as caracterĂ­sticas da população podem influenciĂĄ-los. Da mesma forma, foram documentados preditores de discordĂąncia entre a RFR e a reserva de fluxo fracionado (FFR). O Estudo RECOPA, mostrou que a capacidade diagnĂłstica estĂĄ reduzida na “zona cinzenta” da RFR, tornando necessĂĄria a realização de FFR para descartar ou confirmar isquemia. Objetivos: Determinar os preditores de discordĂąncia, integrar as informaçÔes que eles fornecem em um Ă­ndice clĂ­nico-fisiolĂłgico: a “RFR Ajustada”, e comparar sua concordĂąncia com o FFR. MĂ©todos: Usando dados do Estudo RECOPA, os preditores de discordĂąncia em relação Ă  FFR foram determinados na “zona cinzenta” da RFR (0,86 a 0,92) para construir um Ă­ndice (“RFR Ajustada”) que pesaria a RFR juntamente com os preditores de discordĂąncia e avaliar sua concordĂąncia com a FFR. Resultados: Foram avaliadas 156 lesĂ”es em 141 pacientes. Os preditores de discordĂąncia foram: doença renal crĂŽnica, cardiopatia isquĂȘmica prĂ©via, lesĂ”es nĂŁo envolvendo a artĂ©ria descendente anterior esquerda e sĂ­ndrome coronariana aguda. Embora limitada, a “RFR Ajustada” melhorou a capacidade diagnĂłstica em comparação com a RFR na “zona cinzenta” (AUC-RFR = 0,651 versus AUC-“RFR Ajustada” = 0,749), mostrando tambĂ©m uma melhora em todos os Ă­ndices diagnĂłsticos quando foram estabelecidos limiares de corte otimizados (sensibilidade: 59% a 68%; especificidade: 62% a 75%; acurĂĄcia diagnĂłstica: 60% a 71%; razĂŁo de verossimilhança positiva: 1,51 a 2,34; razĂŁo de verossimilhança negativa: 0,64 a 0,37). ConclusĂ”es: Ajustar a RFR integrando as informaçÔes fornecidas pelos preditores de discordĂąncia para obter a “RFR Ajustada” melhorou a capacidade diagnĂłstica em nossa população. Mais estudos sĂŁo necessĂĄrios para avaliar se os Ă­ndices clĂ­nico-fisiolĂłgicos melhoram a capacidade diagnĂłstica da RFR ou de outros Ă­ndices coronarianos

    Clinical follow-up of long nontapered sirolimus-eluting coronary stent in real-world patients with de novo lesions. The Billar registry

    Full text link
    Introduction and objectives: Coronary lesions with stent overlapping are associated with higher neointimal proliferation that leads to more restenosis. Furthermore, the tapering of coronary arteries is a major challenge when treating long coronary lesions. This study attempted to assess the safety and clinical level of performance of long nontapered sirolimus-eluting coronary stent systems (> 36 mm) to treat long and diffused de novo coronary lesions in real-world scenarios. Methods: This was a prospective, non-randomized, multicentre study that included 696 consecutive patients treated with the long nontapered BioMime sirolimus-eluting coronary stent system in long and diffused de novo coronary lesions. The safety endpoint was major adverse cardiovascular events defined as a composite of cardiac death, myocardial infarction, clinically driven target lesion revascularization, stent thrombosis, and major bleeding at the 12-month follow-up. Results: Of a total of 696 patients, 38.79% were diabetic. The mean age of all the patients was 64.6 +/- 14 years, and 80% were males. The indication for revascularization was acute coronary syndrome in 63.1%. A total of 899 lesions were identified out of which 742 were successfully treated with long BioMime stents (37 mm, 40 mm, 44 mm, and 48 mm). The cumulative incidence of major adverse cardiovascular events was 8.1% at the 12-month follow-up including cardiac death (2.09%), myocardial infarction (1.34%), and total stent thrombosis (0.5%). Conclusions: This study confirms the safety and good performance of long nontapered BioMime coronary stents to treat de novo coronary stenosis. Therefore, it can be considered a safe and effective treatment for long and diffused de novo coronary lesions in the routine clinical practice

    Predictive Value of Cardiac Magnetic Resonance Feature Tracking after Acute Myocardial Infarction: A Comparison with Dobutamine Stress Echocardiography

    Full text link
    [EN] In acute ST-segment elevation myocardial infarction (STEMI) late gadolinium enhancement (LGE) may underestimate segmental functional recovery. We evaluated the predictive value of cardiac magnetic resonance (CMR) feature-tracking (FT) for functional recovery and whether it incremented the value of LGE compared to low-dose dobutamine stress echocardiography (LDDSE) and speckle-tracking echocardiography (STE). Eighty patients underwent LDDSE and CMR within 5-7 days after STEMI and segmental functional recovery was defined as improvement in wall-motion at 6-months CMR. Optimal conventional and FT parameters were analyzed and then also applied to an external validation cohort of 222 STEMI patients. Circumferential strain (CS) was the strongest CMR-FT predictor and addition to LGE increased the overall accuracy to 74% and was especially relevant in segments with 50-74% LGE (AUC 0.60 vs. 0.75, p = 0.001). LDDSE increased the overall accuracy to 71%, and in the 50-74% LGE subgroup improved the AUC from 0.60 to 0.69 (p = 0.039). LGE + CS showed similar value as LGE + LDDSE. In the validation cohort, CS was also the strongest CMR-FT predictor of recovery and addition of CS to LGE improved overall accuracy to 73% although this difference was not significant (AUC 0.69, p = 0.44). Conclusion: CS is the strongest CMR-FT predictor of segmental functional recovery after STEMI. Its incremental value to LGE is comparable to that of LDDSE whilst avoiding an inotropic stress agent. CS is especially relevant in segments with 50-74% LGE where accuracy is lower and further testing is frequently required to clarify the potential for recovery.This research was supported by the Instituto de Salud Carlos III and co-funded by Fondo Europeo de Desarrollo Regional (FEDER) (grant numbers PI17/01836 and CIBERCV16/11/00486). JG and DM acknowledge financial support from the "Agencia Valenciana de la Innovacion, Generalitat Valenciana" (grant) and from the "Conselleria d'Educacio, Investigacio, Cultura i Esport, Generalitat Valenciana" (grant number AEST/2019/037).Valente, FX.; Gavara-Doñate, J.; Gutiérrez, L.; Rios-Navarro, C.; Rello, P.; Maymi, M.; Fernandez-Galera, R.... (2021). Predictive Value of Cardiac Magnetic Resonance Feature Tracking after Acute Myocardial Infarction: A Comparison with Dobutamine Stress Echocardiography. Journal of Clinical Medicine. 10(22):1-12. https://doi.org/10.3390/jcm10225261S112102

    Predictive Value of Cardiac Magnetic Resonance Feature Tracking after Acute Myocardial Infarction: A Comparison with Dobutamine Stress Echocardiography

    Get PDF
    EcocardiografĂ­a de seguimiento de manchas; DeformaciĂłn del miocardio; Seguimiento de caracterĂ­sticas de resonancia magnĂ©tica cardĂ­acaSpeckle-tracking echocardiography; Myocardial deformation; Cardiac magnetic resonance feature-trackingEcocardiografia de seguiment de taques; DeformaciĂł del miocardi; Seguiment de caracterĂ­stiques de ressonĂ ncia magnĂštica cardĂ­acaIn acute ST-segment elevation myocardial infarction (STEMI) late gadolinium enhancement (LGE) may underestimate segmental functional recovery. We evaluated the predictive value of cardiac magnetic resonance (CMR) feature-tracking (FT) for functional recovery and whether it incremented the value of LGE compared to low-dose dobutamine stress echocardiography (LDDSE) and speckle-tracking echocardiography (STE). Eighty patients underwent LDDSE and CMR within 5–7 days after STEMI and segmental functional recovery was defined as improvement in wall-motion at 6-months CMR. Optimal conventional and FT parameters were analyzed and then also applied to an external validation cohort of 222 STEMI patients. Circumferential strain (CS) was the strongest CMR-FT predictor and addition to LGE increased the overall accuracy to 74% and was especially relevant in segments with 50–74% LGE (AUC 0.60 vs. 0.75, p = 0.001). LDDSE increased the overall accuracy to 71%, and in the 50–74% LGE subgroup improved the AUC from 0.60 to 0.69 (p = 0.039). LGE + CS showed similar value as LGE + LDDSE. In the validation cohort, CS was also the strongest CMR-FT predictor of recovery and addition of CS to LGE improved overall accuracy to 73% although this difference was not significant (AUC 0.69, p = 0.44). Conclusion: CS is the strongest CMR-FT predictor of segmental functional recovery after STEMI. Its incremental value to LGE is comparable to that of LDDSE whilst avoiding an inotropic stress agent. CS is especially relevant in segments with 50–74% LGE where accuracy is lower and further testing is frequently required to clarify the potential for recovery.This research was supported by the Instituto de Salud Carlos III and co-funded by Fondo Europeo de Desarrollo Regional (FEDER) (grant numbers PI17/01836 and CIBERCV16/11/00486). JG and DM acknowledge financial support from the “Agencia Valenciana de la InnovaciĂłn, Generalitat Valenciana” (grant) and from the “Conselleria d’EducaciĂł, InvestigaciĂł, Cultura i Esport, Generalitat Valenciana” (grant number AEST/2019/037)

    Spontaneous reperfusion enhances succinate concentration in peripheral blood from stemi patients but its levels does not correlate with myocardial infarct size or area at risk

    Get PDF
    Cardiovascular biology; Diagnostic markers; Prognostic markersBiologĂ­a cardiovascular; Marcadores de diagnĂłstico; Marcadores pronĂłsticosBiologia cardiovascular; Marcadors diagnĂČstics; Marcadors pronĂČsticsSuccinate is enhanced during initial reperfusion in blood from the coronary sinus in ST-segment elevation myocardial infarction (STEMI) patients and in pigs submitted to transient coronary occlusion. Succinate levels might have a prognostic value, as they may correlate with edema volume or myocardial infarct size. However, blood from the coronary sinus is not routinely obtained in the CathLab. As succinate might be also increased in peripheral blood, we aimed to investigate whether peripheral plasma concentrations of succinate and other metabolites obtained during coronary revascularization correlate with edema volume or infarct size in STEMI patients. Plasma samples were obtained from peripheral blood within the first 10 min of revascularization in 102 STEMI patients included in the COMBAT-MI trial (initial TIMI 1) and from 9 additional patients with restituted coronary blood flow (TIMI 2). Metabolite concentrations were analyzed by 1H-NMR. Succinate concentration averaged 0.069 ± 0.0073 mmol/L in patients with TIMI flow ≀ 1 and was significantly increased in those with TIMI 2 at admission (0.141 ± 0.058 mmol/L, p < 0.05). However, regression analysis did not detect any significant correlation between most metabolite concentrations and infarct size, extent of edema or other cardiac magnetic resonance (CMR) variables. In conclusion, spontaneous reperfusion in TIMI 2 patients associates with enhanced succinate levels in peripheral blood, suggesting that succinate release increases overtime following reperfusion. However, early plasma levels of succinate and other metabolites obtained from peripheral blood does not correlate with the degree of irreversible injury or area at risk in STEMI patients, and cannot be considered as predictors of CMR variables. Trial registration: Registered at www.clinicaltrials.gov (NCT02404376) on 31/03/2015. EudraCT number: 2015-001000-58.This work was supported by the Spanish Ministry of Economy and Competitiveness, Instituto de Salud Carlos III (Grants PI17/01397 and CIBERCV) and the Spanish Society of Cardiology (Proyectos de la FEC para InvestigaciĂłn BĂĄsica en CardiologĂ­a 2018, Sociedad Española de CardiologĂ­a), and was cofinanced by the European Regional Development Fund (ERDF-FEDER, a way to build Europe). Antonio RodrĂ­guez-Sinovas has a consolidated Miguel Servet contract

    Genetic association study of coronary collateral circulation in patients with coronary artery disease using 22 single nucleotide polymorphisms corresponding to 10 genes involved in postischemic neovascularization

    Get PDF
    Background: collateral growth in patients with coronary artery disease (CAD) is highly heterogeneous. Although multiple factors are thought to play a role in collateral development, the contribution of genetic factors to coronary collateral circulation (CCC) is largely unknown. The goal of this study was to assess whether functional single nucleotide polymorphisms (SNPs) in genes involved in vascular growth are associated with CCC. Methods: 677 consecutive CAD patients were enrolled in the study and their CCC was assessed by the Rentrop method. 22 SNPs corresponding to 10 genes involved in postischemic neovascularization were genotyped and multivariate logistic regression models were adjusted using clinically relevant variables to estimate odds ratios and used to examine associations of allelic variants, genotypes and haplotypes with CCC. Results: statistical analysis showed that the HIF1A rs11549465 and rs2057482; VEGFA rs2010963, rs1570360, rs699947, rs3025039 and rs833061; KDR rs1870377, rs2305948 and rs2071559; CCL2 rs1024611, rs1024610, rs2857657 and rs2857654; NOS3 rs1799983; ICAM1 rs5498 and rs3093030; TGFB1 rs1800469; CD53 rs6679497; POSTN rs3829365 and rs1028728; and LGALS2 rs7291467 polymorphisms, as well as their haplotype combinations, were not associated with CCC (p < 0.05). Conclusions: we could not validate in our cohort the association of the NOS3 rs1799983, HIF1A rs11549465, VEGFA rs2010963 and rs699947, and LGALS2 rs7291467 variants with CCC reported by other authors. A validated SNP-based genome-wide association study is required to identify polymorphisms influencing CCC

    Ajustando a RFR por Preditores de Discordñncia, “A RFR Ajustada”: Uma Metodologia Alternativa para Melhorar a Capacidade Diagnóstica dos Índices Coronarianos

    No full text
    Angina de pecho; Reserva de flujo fraccional; SensibilidadAngina de pit; Reserva de flux fraccionari; SensibilitatAngina; Fractional flow reserve; SensitivityBackground Cutoff thresholds for the “resting full-cycle ratio” (RFR) oscillate in different series, suggesting that population characteristics may influence them. Likewise, predictors of discordance between the RFR and fractional flow reserve (FFR) have been documented. The RECOPA Study showed that diagnostic capacity is reduced in the RFR “grey zone”, requiring the performance of FFR to rule out or confirm ischemia. Objectives To determine predictors of discordance, integrate the information they provide in a clinical-physiological index, the “Adjusted RFR”, and compare its agreement with the FFR. Methods Using data from the RECOPA Study, predictors of discordance with respect to FFR were determined in the RFR “grey zone” (0.86 to 0.92) to construct an index (“Adjusted RFR”) that would weigh RFR together with predictors of discordance and evaluate its agreement with FFR. Results A total of 156 lesions were evaluated in 141 patients. Predictors of discordance were: chronic kidney disease, previous ischemic heart disease, lesions not involving the anterior descending artery, and acute coronary syndrome. Though limited, the “Adjusted RFR” improved the diagnostic capacity compared to the RFR in the “grey zone” (AUC-RFR = 0.651 versus AUC-“Adjusted RFR” = 0.749), also showing an improvement in all diagnostic indices when optimal cutoff thresholds were established (sensitivity: 59% to 68%; specificity: 62% to 75%; diagnostic accuracy: 60% to 71%; positive likelihood ratio: 1.51 to 2.34; negative likelihood ratio: 0.64 to 0.37). Conclusions Adjusting the RFR by integrating the information provided by predictors of discordance to obtain the “Adjusted RFR” improved the diagnostic capacity in our population. Further studies are required to evaluate whether clinical-physiological indices improve the diagnostic capacity of RFR or other coronary indices

    Coronary Endothelium‐Dependent Vasomotor Function After Drug‐Eluting Stent and Bioresorbable Scaffold Implantation

    Get PDF
    Background Early generation drug-eluting stents (DESs) showed a high grade of coronary endothelial dysfunction that was attributed to lack of stent reendothelialization. Endothelium-dependent vasomotor response of current DESs and bioresorbable scaffolds (BRSs) remains unknown. This study sought to assess the device-related endothelial function of current devices and to correlate neointima healing with endothelial function. Methods and Results A total of 206 patients from 4 randomized trials treated with the durable-polymer everolimus-eluting Xience (n=44), bioresorbable-polymer sirolimus-eluting Orsiro (n=35), polymer-free biolimus-eluting Biofreedom (n=24), bioactive endothelial-progenitor cell-capturing sirolimus-eluting Combo DES (n=25), polymer-based everolimus-eluting Absorb (n=44), and Mg-based sirolimus-eluting Magmaris BRS (n=34) underwent endothelium-dependent vasomotor tests and optical coherence tomography imaging, as per protocol, at follow-up. Crude vasomotor responses of distal segments to low-dose acetylcholine (10-6 mol/L) were different between groups: bioresorbablepolymer DEShad the worst (-8.4%±12.6%) and durable-polymer DES had the most physiologic (-0.4%±11.8%; P=0.014). High-dose acetylcholine (10-4 mol/L) showed similar responses between groups (ranging from -10.8%±11.6% to -18.1%±15.4%; P=0.229). Device healing was different between devices. Uncovered struts ranged from 6.3%±7.1% (bioresorbable-polymer DES) to 2.5%±4.5% (bioactive DES; P=0.056). In multivariate models, endothelium-dependent vasomotor response was associated with age, bioresorbable-polymer DES, and angiographic lumen loss, but not with strut coverage nor plaque type. Endothelial dysfunction (defined as ≄4% vasoconstriction) was observed in 46.6% of patients with low-dose and 68.9% with high-dose acetylcholine, without differences between groups. Conclusions At follow-up, endothelial dysfunction was frequently observed in distal segments treated with current stents without remarkable differences between devices. Although neointima healing was different between devices, poor healing was not associated with endothelial dysfunction
    corecore