124 research outputs found

    Effect of Titanium-Base Abutment Height on Optical Properties of Monolithic Anterior Zirconia Crowns.

    Get PDF
    The effects of different heights of ti-base abutments on the color of anterior screw-retained zirconia restorations fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technologies may affect the optical clinical outcome. The purpose of this study was to measure and compare the color parameters of zirconia crowns in different shades on ti-base abutments. Identical specimens (N = 160) were milled to restore the screw-retained central maxillary incisor crown, using 5% mol yttria zirconia (5Y-TZP). The specimens were designed using computer design software to match 3.5 mm and 5.5-mm ti-base abutments and milled using one CAD-CAM technology. Specimens were divided into four main groups depending on zirconia shade (A1/0, A2/3, A3.5/4 and B2/3) and then assigned to two subgroups according to ti-base height. Color measurements in the CIELab coordinates were made using a spectrophotometer under room-light conditions. Color difference (ΔE*) values were calculated using the CIE76 and CIEDE2000 formula. Within the group of A0/1 and A2/3, for 5.5 mm abutment height, a significant difference was found between the means of colors ∆E00 and ∆Eab (p < 0.01). Using a 5.5 mm-height ti-base abutment may produce a clinically unacceptable outcome (ΔEab > 2) in A1/0 and A2/3 color groups

    The role of IL-1 gene polymorphisms (IL1A, IL1B, and IL1RN) as a risk factor in unsuccessful implants retaining overdentures

    Get PDF
    Purpose: Implant-supported overdentures are an alternative predictable rehabilitation method that has a high impact on improving the patient's quality of life. However, some biological complications may interfere with the maintenance and survival of these overdenture implants. The goal of this article was to assess the factors that affect periimplant success, through a hypothetical prediction model for biological complications of implant overdentures.Methods: A retrospective observational, prevalence study was conducted in 58 edentulous Caucasian patients rehabilitated with implant overdentures. A total of 229 implants were included in the study. Anamnestic, clinical, and implant-related parameters were collected and recorded in a single database. "Patient" was chosen as the unit of analysis, and a complete screening protocol was established. The data analytical study included assessing the odds ratio, concerning the presence or absence of a particular risk factor, by using binary logistic regression modeling. Probability values (p values) inferior to 0.05 were considered as representing statistically significant evidence.Results: The performed prediction model included the following variables: mean probing depth, metal exposure, IL1B_allele2, maxillary edentulousness, and Fusobacterium nucleatum. The F. nucleatum showed significant association with the outcome. Introducing a negative coefficient appeared to prevent complications or even boost the biological defense when associated with other factors.Conclusions: The prediction model developed in this study could serve as a basis for further improved models that would assist clinicians in the daily diagnosis and treatment planning practice of oral rehabilitation with implant overdentures.info:eu-repo/semantics/publishedVersio

    Gestion de l'édenté partiel

    No full text

    Bone strain measurements and implant micro-surface analysis of drill-less self-threading dental implants - preliminary in-vitro results

    No full text
    Sin financiación1.506 JCR (2019) Q4, 131/143 Endocrinology & Metabolism, 140/158 Immunology, 112/138 Medicine, Research & Experimental, 68/81 Physiology0.395 SJR (2019) Q3, 75/107 Physiology (medical), 251/367 Oncology, 140/202 Immunology and Allergy, 153/239 Endocrinology, Diabetes and Metabolism; Q4, 174/214 Cancer Research, 100/129 Endocrinology, 167/225 Immunology, 144/186 PhysiologyNo data IDR 2019UE

    Effects of Aging Torque Controllers on Screw Tightening Force and Bacterial Micro-Leakage on the Implant-Abutment Complex

    No full text
    Aim: We assess the accuracy of torque controllers after several aging processes and the bacterial leakage on implant-abutment complexes (IAC). Methods: A total of 12 spring-type and 12 friction-type torque controllers and 48 IAC (24 conical and 24 hexagonal connections) were evaluated. Chemical, mechanical, temperature, and pressure-aging methods were applied individually to replicate clinical use. Torque controller accuracy was analyzed before and after aging using a calibrated gauge. To assess bacterial leakage, the IAC were suspended in a bacterial medium for 24 h. Direct Contact Test (DCT) and Polymerase Chain Reaction Test (RT-PCR) analyzed the infiltration of F. nucleatum and P. gingivalis into the IAC micro-gap. Results: A significant decrease in torque after 10 days of aging was found. The spring-type torque controller was affected the most, regardless of the aging method (P < 0.05). PCR results indicated that all groups exhibited significantly more bacterial leakage, regardless of the method used (P < 0.05). The conical IAC demonstrated more bacterial leakage of P. gingivalis compared with the hexagonal IAC (P = 0.07). DCT found bacterial growth in the IAC only before aging and was not identified after aging. Conclusion: Aging affects torque accuracy. A reduction in force was noticed after 10 days. The conical IAC exhibits more bacterial leakage, although this was not statistically significant

    Differences in crestal bone-to-implant contact following an under-drilling compared to an over-drilling protocol. A study in the rabbit tibia

    No full text
    The objective of this study is to compare bone-to-implant contact (BIC) between implants inserted at high torque due to under-drilling of the crestal bone to those inserted at low torque due to over-drilling of the crestal bone. Forty implants with diameters of 3.75 mm (group A) or 3.55 mm (group B) were inserted in the proximal tibiae of NZW rabbits in two separate surgeries on day 0 or 21. Osteotomy of the crestal bone was finalized with a 3.65-mm drill. In group A, implants were inserted at torque ae35 Ncm (under-drilling) and in group B with torque 0.05). No differences in t-BIC were noted at 3 weeks and at 6 weeks between the groups. Insertion of implants with an over-drilling protocol of the crestal aspect of the osteotomy resulted in increased short-term crestal bone-to-implant contact. Insertion of implants with a high torque following an under-drilling protocol, commonly used for immediate loading, may reduce crestal bone-to-implant contact at early healing stages

    Consensus conference on immediate loading: the single tooth and partial edentulous areas.

    No full text
    • …
    corecore