10,348 research outputs found

    Quantum Properties of a Which-Way Detector

    Full text link
    We explore quantum properties of a which-way detector using three versions of an idealized two slit arrangements. Firstly we derive complementarity relations for the detector; secondly we show how the "experiment" may be altered in such a way that using single position measurement on the screen we can obtain quantum erasure. Finally we show how to construct a superposition of "wave" and "particle" components

    Searching High Redshift Large-Scale Structures: Photometry of Four Fields Around Quasar Pairs at z~1

    Full text link
    We have studied the photometric properties of four fields around the high-redshift quasar pairs QP1310+0007, QP1355-0032, QP0110-0219, and QP0114-3140 at z ~ 1 with the aim of identifying large-scale structures- galaxy clusters or groups- around them. This sample was observed with GMOS in Gemini North and South telescopes in the g', r', i', and z' bands, and our photometry is complete to a limiting magnitude of i' ~ 24 mag (corresponding to ~ M*_i' + 2 at the redshift of the pairs). Our analysis reveals that QP0110-0219 shows very strong and QP1310+0007 and QP1355-0032 show some evidence for the presence of rich galaxy clusters in direct vicinity of the pairs. On the other hand, QP0114-3140 could be an isolated pair in a poor environment. This work suggest that z ~ 1 quasar pairs are excellent tracers of high density environments and this same technique may be useful to find clusters at higher redshifts.Comment: 29 pages, 7 figures, ApJ accepted. Added one figure and 3 references. Some paragraphs was rewritten in sections 1, 3, 5, and 6, as suggested by refere

    ANALYTICAL SOLUTION OF A 2D TRANSIENT HEAT CONDUCTION PROBLEM USING GREEN´S FUNCTIONS

    Get PDF
    Through the present work the authors determined the analytical solution of a transient two-dimensional heat conduction problem using Green’s Functions (GF). This method is very useful for solving cases where heat conduction is transient and whose boundary conditions vary with time. Boundary conditions of the problem in question, with rectangular geometry, are of the prescribed temperature type - prescribed flow in the direction x and prescribed flow - prescribed flow in the direction y, implying in the corresponding GF given by GX21Y22. The initial temperature of the space domain is assumed to be different from the prescribed temperature occurring at one of the boundaries along x. The temperature field solution of the two-dimensional problem was determined. The intrinsic verification of this solution was made by comparing the solution of a 1D problem. This was to consider the incident heat fluxes at y = 0 and y = 2b tending to zero, thus making the problem one-dimensional, with corresponding GF given by GX21. When comparing the results obtained in both cases, for a time of t = 1 s, it was seen that the temperature field of both was very similar, which validates the solution obtained for the 2D problem

    Finasteride quantification in human plasma by high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry. application to a comparative pharmacokinetics study

    Get PDF
    A specific, fast and sensitive LC-MS/MS assay was developed for the determination of finasteride in human plasma using betamethsone dipropionate as the internal standard (IS). The limit of quantification was 1.0 ng/ml and the method was linear in the range of 1.0–25.0 ng/ml. The retention times were 0.75 min for finasteride and 0.85 min for IS. Method intra-batch precision and accuracy ranged from 3.6 to 7.1%, and 96.6 to 103.9%, respectively. Inter-batch precision ranged from 2.5 to 3.4%, while Inter-batch accuracy ranged from 100.3 to 103.5%. The analytical method was applied to evaluate the pharmacokinetic and relative bioavailability of 2 different pharmaceutical formulations containing 1.0 mg of finasteride. This study evaluated 38 volunteers in a randomized, 2-period crossover study with 7 days washout period between doses. The geometric mean and respective 90% CI of finasteride test/reference percent ratios were 95.68% (91.2 – 104.6%) for Cmax, 97.5% (92.1 –103.3%) for AUC0-t and 98.1 (92.67−103.8) for AUC0-inf. Based on the 90% confidence interval of the individual ratios (test formulation/reference formulation) for Cmax and AUC0-inf, it was concluded that the test formulation is bioequivalent to the reference one with respect to the rate and extent of absorption of finasteride65944945

    Gauging N=2 Supersymmetric Non-Linear σ\sigma-Models in the Atiyah-Ward Space-Time

    Full text link
    We build up a class of N=2 supersymmetric non-linear σ\sigma-models in an N=1 superspace based on the Atiyah-Ward space-time of (2+2)-signature metric. We also discuss the gauging of isometries of the associated hyper-K\"ahlerian target spaces and present the resulting gauge-covariant supersymmetric action functional.Comment: 12 pages, latex, no figure
    • …
    corecore