13 research outputs found

    Adhesion of dental sealants to enamel with self-etching adhesives in salivar contamination conditions: Influence of the light curing protocol

    Get PDF
    Purpose: To evaluate the influence of the light curing protocol in the shear bond strength of a sealant to enamel treated with two self-etching adhesive systems, in salivary contamination conditions. Materials and Methods: The dental sealant (Delton, Dentsply) was applied, after saliva contamination, onto the vestibular enamel of sixty human incisors treated with Xeno III (Dentsply) or Prompt-L-Pop (3M/Espe). These two groups were further divided into two subgroups (n = 15) according to the curing time: 1) the adhesive system was cured with the sealant (co-polymerization), and 2) adhesive and sealant were light cured independently (independent polymerization). After the adhesive procedures, specimens were stored in water (37 °C–24 h) and thermal-cycled. Shear bond strength tests were done in an universal testing machine. Data was analyzed with two-way ANOVA. Results: There were no statistical differences (p = 0.267) between the adhesive systems tested. The co-polymerization groups (33.3 ± 9.4 MPa) yielded statistically higher shear bond strength values than the independent polymerization groups (28.2 ± 4.7 MPa). Even with saliva contamination, the self-etching adhesive systems used yielded high shear bond strength values. Conclusions: In the conditions tested, the co-polymerization of the adhesive systems with the sealant led to higher bond strength values to enamel than the independent polymerization.Objectivos: Avaliar a influência do momento da fotopolimerização de dois sistemas adesivos auto-condicionantes, nos valores de resistência adesiva de um selante de fissuras ao esmalte, em condições de contaminação salivar. Materiais e Métodos: O selante de fissuras (Delton, Dentsply) foi aplicado, após contaminação salivar, sobre o esmalte vestibular de sessenta incisivos humanos condicionados com Xeno III (Dentsply) ou Prompt-L-Pop (3M/Espe). Estes dois grupos foram posteriormente divididos em dois subgrupos (n = 15) de acordo com o momento da fotopolimerização do sistema adesivo: 1) o sistema adesivo foi fotopolimerizado conjuntamente com o selante (co-polymerization), e 2) sistema adesivo e selante foram fotopolimerizados independentemente (independent polymerization). Os espécimes foram armazenados em água (37 °C–24 h) e, posteriormente, submetidos a termociclagem. Os ensaios de resistência adesiva foram realizados numa máquina de testes universal. Os resultados foram submetidos a análise estatística ANOVA duas vias. Resultados: Não foram registadas diferenças estatisticamente significativas (p = 0,267) entre os sistemas adesivos usados. Os grupos co-polimerizados obtiveram valores de resistência adesiva mais elevados (33,3 ± 9,4 MPa) relativamente aos grupos em que a polimerização foi realizada de forma independente (28,2 ± 4,7 MPa). Mesmo na presença de contaminação salivar, os sistemas adesivos auto-condicionantes testados obtiveram valores de resistência adesiva elevados. Conclusões: Nas condições testadas, a co-polimerização do sistema adesivo com o selante originou valores de resistência adesiva ao esmalte superiores relativamente à polimerização independente destes dois materiais.info:eu-repo/semantics/publishedVersio

    Como os políticos portugueses utilizam a internet em campanha eleitoral

    Get PDF
    Dissertação apresentada para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Ciências da ComunicaçãoA presente dissertação aborda o tema da utilização da Internet nas campanhas eleitorais e a sua influência nos resultados das eleições. Especificamente, foi escolhido como objecto de estudo as eleições legislativas de 2009 em Portugal, sendo dado um especial enfoque ao período oficial de campanha eleitoral, entre os dias 12 e 25 de Setembro daquele ano. Face ao elevado número de partidos que concorreram às eleições optou-se pela análise exaustiva de um só partido, o Partido Social Democrata (PSD). Houve também um acompanhamento mais superficial do Partido Socialista (PS) pois desta forma foi possível algum nível de comparação entre os dois maiores partidos portugueses. O objectivo específico do projecto foi analisar a forma como os responsáveis políticos utilizaram a Internet no período da campanha, percebendo, sob o ponto de vista estratégico, qual o peso que foi dado àquele meio de comunicação. Em particular, foi avaliada a presença dos partidos em redes sociais como o Twitter e o Facebook, em blogues de campanha (oficiais e não oficiais) e também no YouTube. Foi efectuada uma comparação, em termos de eficácia na transmissão da mensagem política, entre a informação fornecida pelos partidos através da Internet e a disponibilizada através de outros meios de comunicação mais tradicionais, tais como a televisão e os jornais. Foi utilizada como referência externa a campanha para as eleições presidenciais norteamericanas de 2008, pois é noção geralmente aceite que nesta campanha a Internet assumiu um papel decisivo

    Permeabilidade dentinária e morfologia da interface adesiva de diferentes sistemas adesivos

    Get PDF
    Objetivos: Comparar a permeabilidade dentinária de vários sistemas adesivos com e sem camada hidrófoba. Analisar a influência da pressão pulpar na morfologia da interface adesiva. Métodos: No ensaio de permeabilidade, os espécimes foram distribuídos aleatoriamente por quatro grupos (n = 9), de acordo com os sistemas adesivos estudados: Futurabond U (Voco) self-etch; Futurabond U etch-and-rinse; Scotchbond 1 XT (3M-Espe); Easybond (3M-Espe), com posterior aplicação de resina hidrófoba [Adhesive; sistema Scotchbond Multipurpose (3M-Espe)]. A condutância hidráulica de cada espécime foi medida num dispositivo de permeabilidade. Para caracterização da morfologia da interface adesiva, em microscópio eletrônico de varredura, foram usados três espécimes de cada grupo submetido a pressão pulpar e novos espécimes (n = 3) foram preparados sem pressão pulpar com os mesmos sistemas adesivos, que formaram os quatro grupos descritos. A permeabilidade dos diferentes sistemas adesivos foi comparada com Anova e post hoc segundo Tukey (p < 0,05). A permeabilidade antes e após a camada de resina hidrófoba foi comparada com o teste T emparelhado, de medic¸ões repetidas. Resultados: A permeabilidade foi significativamente menor com o Futurabond U versão self-etch em comparação com os grupos etch-and-rinse (p < 0,05), tanto antes como após a aplicação da resina hidrófoba A camada hidrófoba reduziu significativamente (p < 0,05) os valores de permeabilidade, para todos os adesivos. Não se identificou camada híbrida nos grupos self-etch, contrariamente aos grupos etch-and-rinse. Constataram-se alterações na interface quando aplicada pressão pulpar. Conclusões: A camada de resina hidrófoba reduziu os valores de permeabilidade em todos os sistemas adesivos. A feitura do procedimento adesivo sob pressão pulpar originou defeitos estruturais em todos os grupos.Objective: Compare dentine permeability of different adhesive systems with and without hydrophobic resin. Analyze the influence of pulpal pressure on the morphology of the adhesive interface. Methods: For the permeability assay, teeth were randomly allocated in 4 groups (n = 9), according to the adhesive systems: Futurabond U (Voco) self-etch; Futurabond U etch-and- -rinse; Scotchbond 1 XT (3M-Espe); Easybond (3M-Espe) with subsequent application of an hydrophobic resin [Adhesive; Scotchbond Multipurpose system (3M-Espe)]. Hydraulic conductance of each specimen was measured on a permeability apparatus. To characterize the morphology of the adhesive interface in scanning electron microscope, 3 specimens from each group subjected to pulpal pressure were used, and new specimens (n = 3) were prepared without pulpal pressure, according to the same adhesive system, forming the 4 groups described before. Permeability of the different adhesive systems was compared with Anova and Tukey post-hoc (p < 0.05). Permeability before and after the hydrophobic resin layer was compared with a paired t student test for repeated measures. Results: Permeability was significantly lower with Futurabond U self-etch when compared to the etch-and-rinse groups (p < 0.05), both before and after hydrophobic resin layer application. Hydrophobic resin layer lead to a significant reduction on the permeability for all adhesive systems (p < 0.05). Hybrid layer was not identified on the self-etch groups as opposed to the etch-and-rinse groups. Adhesive interface had alterations when the pulpal pressure was applied. Conclusion: Hydrophobic resin layer reduced the permeability in all adhesive systems tested. Structural defects were present in all groups when the adhesive procedures were performed under pulpal pressure.info:eu-repo/semantics/publishedVersio

    Influência da técnica de acabamento e do tempo de exposição na estabilidade cromática do bis-acrílico

    Get PDF
    Objetivo: Avaliar o efeito do tipo de polimento e tempo de exposição ao café na estabilidade cromática de 2 resinas bis-acrílicas. Métodos: Foram preparados 60 discos em resina bis acrílica, 30 com Protemp-4 e 30 comStructur-3. As faces dos discos foram limpas com álcool e os espécimes divididos em12 grupos experimentais (n = 5), de acordo com tipo de resina e método de polimento (sem tratamento adicional; escova pelo-de-cabra; disco de grão grosso Sof-Lex seguido de escova pelo-de-cabra; sequência de discos Sof-Lex; disco de grão grosso Sof-Lex seguidode aplicação de Fortify; disco de grão grosso Sof-Lex seguido de Z-Prime Plus). Sessenta minutos após o polimento foi realizada a medição de cor inicial (CIE L*a*b*) e os espécimes foram imersos em café. Após 24 horas e 7 dias de imersão foram realizadas novas medições de cor. A diferença cromática foi calculada com a fórmula E* = [(L*)2+ ( _a*)2+ ( _b*)2]1/2.Os dados foram analisados com testes estatísticos segundo os métodos de Kruskal-Wallis,Mann-Whitney e Wilcoxon (alfa = 0,05).Resultados: Os valores _E variaram entre 4,9-11,7 (24 horas) e 13,3-21,4 (7 dias). O aumento do tempo de imersão do bis acrílico no café conduziu a aumento de E (p < 0,001). Às 24 horas não se encontraram diferenças entre os materiais (p = 0,941). Ao fim de 7 dias o Protemp-4 mostrou valores E (p = 0,032) inferiores aos obtidos com a Structur-3. Com exceção doProtemp-4 com 7 dias de imersão, a E foi influenciada pelo método de polimento (p < 0,05) Conclusão: Todos os espécimes apresentaram valores de _E considerados clinicamente inaceitáveis.Aim: To study the effect of several polishing techniques and exposure time to a staining agent on the color stability of two bis-acrylic resins. Methods: 60 cylindrical specimens of bis-acrylic were prepared, 30 with Protemp-4 and 30 with Strutur-3. Both sides of specimens were cleaned with alcohol and the specimens were allocated to 12 experimental groups (n = 5) according to the material and surface treatment performed (without any other treatment, goat hair brushes, Sof-Lex coarser grit disc fol-lowed by goat hair brushes, Sof-Lex sequence, Sof-Lex coarser grit disc with Fortify, Sof-Lex coarser grit disc with Z-Prime Plus). Sixty minutes after polishing, the baseline colour values (CIE L*a*b*) were measured, and all the specimens were immersed in the staining solution (coffee). After 24 hours and 7 days additional measurements were taken. Colour changes were calculated by the formula: _E* = [( L*)2 + ( _a*)2 + ( _b*)2]1/2. All data were statistically analysed by non-parametric tests according to Kruskal-Wallis, Mann-Whitney and Wilcoxon methods (alpha = 0.05). Results: _E mean values ranged between 4.9 and 11.7 after 24 hours of immersion and between 13.3 and 21.4 after 7 days. Increasing the immersion time in the staining solution led to an increase of _E values (p < 0.001). After 24 hours of immersion, there were no statistical differences among materials (p = 0.941). After 7 days of immersion, Protemp-4 obtained lower E (p = 0.032) than Structur-3. The _E was influenced by the polishing technique, except for Protemp-4 after 7 days of immersion (p < 0.05). Conclusion: All specimens presented values for E that were considered clinically unaccep- table.info:eu-repo/semantics/publishedVersio

    Reparação imediata de restaurações directas em resina composta utilizando sistemas adesivos self-etching

    Get PDF
    Objectivos: Determinar a influência de diversos sistemas adesivos sobre os valores de adesão de reparações imediatas de restaurações em compósito, após a preparação da superfície com abrasivos. Métodos: Foram testados 6 grupos. No G1 a superfície de um disco de compósito (Z100, 3M/ESPE) foi abrasionada antes da aplicação de um novo incremento, e em G2 a superfície do disco de compósito não foi tratada. Nestes dois grupos não foram utilizados sistemas adesivos. Nos restantes 4 grupos foi aplicado um sistema adesivo depois da superfície ser abrasionada e antes do compósito de reparação ser aplicado. Os sistemas adesivos utilizados foram: G3- resina fluida do Scotchbond-MultiPurpose (3M/ESPE), G4- Prompt-L-Pop (3M/ESPE), G5- Adhese (Ivoclar/Vivadent), G6-resina fluida do Adhese (Ivoclar/Vivadent). Os ensaios de resistência adesiva ao corte foram realizados numa máquina de testes universal. Os dados foram tratados estatisticamente com ANOVA e Student-Newman-Keuls. Resultados: O G1 deu origem a valores de resistência adesiva (31.85 +/- 4.5 MPa) significativamente inferiores a todos os outros grupos (p=0.0024). Os restantes grupos apresentaram valores de resistência adesiva semelhantes (p³0,05) (G2 = 48.8+/-14.4 MPa; G3= 48.87+/-12.0 MPa; G4= 47.57+/-6.4 MPa; G5= 61.02+/-8.1 MPa; G6= 52.78+/- 6.9 MPa). Conclusões: O tratamento, com abrasivos, da superfície de uma restauração directa com compósito diminui significativamente a resistência adesiva de um novo incremento. A aplicação de um sistema adesivo após o tratamento abrasivo aumenta esses valores, sendo estes semelhantes aos valores de resistência adesiva obtidos pelas restaurações em que não houve alteração da superfície.Objectives: determine the shear bond strength of immediately repaired direct composite restorations, after grinding the composite surface and after using three different adhesive systems to bond the increment. Methods: In this study one composite resin (Z100, 3M/ESPE) was applied in plate A of the Watanabe single-plane lap shear device in 1 mm increments and polymerized. 2 groups with no adhesive system were tested: G1- abraded composite surfaces, G2- untreated composite surfaces. In the 4 other groups samples were abraded and an adhesive system was applied before the composite increment: G3- bond from Scotchbond Multi Purpose (, 3M/ESPE), G4- Prompt-L-Pop (3M/ESPE), G5- Adhese (Ivoclar/Vivadent), G6- Bond from Adhese (Ivoclar/Vivadent). After each surface preparation, fresh composite was applied in the plate B and polymerized. Samples were stored for 24 hours before testing. Shear bond strength was evaluated, using an universal testing machine (Instron Corp.). Mean +/- standard deviation values were compared using ANOVA and Student-Newman-Keuls test. Results: Samples in G1 (31.85 +/- 4.5 MPa) yielded significantly lower values than samples from all other groups. Samples from groups treated with the adhesives (G3= 48.87+/-12.0 MPa; G4= 47.57+/-6.4 MPa; G5= 61.02+/-8.1 MPa; G6= 52.78+/-6.9 MPa) yielded similar values to samples were the composite surface had no treatment (G2 = 48.8+/-14.4 MPa). Conclusions: Abrasion of the surface of a new direct composite restoration significantly decreased shear bond strength of fresh composite increments. Application of an adhesive material increased shear bond strength of the abraded samples to the same level as the untreated composite surfaces.info:eu-repo/semantics/publishedVersio

    Influência de diferentes matrizes oclusais na fotopolimerização de uma resina composta: análise de microdureza Knoop

    Get PDF
    Objetivo: Determinar a influência de 3 materiais utilizados como matriz oclusal na eficácia de fotopolimerização de uma resina composta e na prevenção da inibição da polimerização superficial. Métodos: Cem espécimes de resina composta (GrandioSO, VOCO) com 2 mm de espessura foram polimerizados (20 segundos), com um LED (800 mW/cm2) interpondo o material em estudo. Estes espécimes formaram os 10 grupos estudados (n = 10) de acordo com o material interposto [sem material interposto, tira de acetato, Registrado Clear (VOCO), Memosil-2 (Heraeus Kulzer) e Bite-perf (BITEPERF Dental Products)] e espessura/distância da luz (1 ou 2 mm). Após 24 horas efetuaram-se testes de microdureza Knoop na base e no topo dos espécimes. Os dados foram tratados estatisticamente com uma MANOVA de 2 dimensões, seguindo-se testes post-hoc pelo método de Tukey, estabelecendo-se 0,05 como nível de significância. Resultados: A distância da luz não produziu diferenças de microdureza estatisticamente significativas (p ≥ 0,05). Os grupos com tira de acetato obtiveram valores de microdureza no topo estatisticamente superiores (p < 0,05) aos obtidos nos outros grupos, seguidos dos grupos com Bite-perf que obtiveram valores estatisticamente inferiores em relação aos grupos com acetato, mas superiores ao restantes grupos (p < 0,05). Para a base, o grupo do Bite-perf foi o único que apresentou valores de microdureza estatisticamente inferiores (p < 0,05), não se verificando diferenças estatisticamente significativas entre os restantes grupos (p ≥ 0,05). Conclusões: O Bite-perf foi o único material que interferiu com a polimerização em profundidade da resina composta e o único que indicia prevenir a inibição da polimerização pelo oxigénio.Objective: To evaluate the influence of three occlusal matrix materials in the light curing effectiveness of a resin composite. Furthermore, we intend to determine if the application of these materials could prevent the oxygen-inhibited layer of the composite surface. Methods: One-hundred composite (GrandioSO, VOCO) specimens, 2 mm thick, were lightcured (20 seconds) with a LED curing device (800 mW/cm2) through the study materials. The specimens were divided into ten groups (n = 10) according to the placed material [no interposed material, mylar strip, Registrado Clear (VOCO), Memosil-2 (Heraeus Kulzer) e Bite-perf (BITEPERF Dental Products)] and thickness / light-cure tip distance (1 and 2 mm). After 24 hours, Knoop microhardness tests were performed at top and bottom surfaces. The data was analyzed with a two-way MANOVA followed by the Tukey post-hoc test. Statistical testing was performed at a 0.05 level of significance. Results: The light-cure tip distance did not show statistical differences (p≥ 0.05). The mylar strip groups showed the highest (p < 0.05) microhardness values on top surface. The Biteperf groups showed lower hardness values comparing to the mylar strip groups, but higher than the other groups (p < 0.05). On the bottom surface, the Bite-perf group presented the lowest values (p < 0.05). There were no statistically significant differences between the other groups (p ≥ 0.05). Conclusions: The Bite-perf was the only material that influenced the resin composite depth of cure and the only that seems to prevent the oxygen-inhibited layer.info:eu-repo/semantics/publishedVersio

    Inibição da polimerização de resinas compostas por materiais usados como matrizes oclusais

    Get PDF
    Objetivo: Estudar o efeito do método de fotopolimerização, da presença do oxigénio e da remoção da camada inibida na microdureza de compósito fotopolimerizado através de matrizes oclusais. Métodos: Discos de compósito (GrandioSO, VOCO) foram fotopolimerizados com LED através de matrizes oclusais (2 polivinilsiloxano: Memosil 2 [Heraeus Kulzer] e Registrado Clear [Voco] e um polietileno: Bite-perf [Biteperf Dental Products]) (n = 10). Foram criados grupos controlo, sem matriz e com matriz de acetato. O estudo foi constituído por 3 etapas. Na primeira foi avaliado o método de fotopolimerização (40 segundos através da matriz; 20 segundo através da matriz + 20 segundos sem matriz). Na segunda etapa os espécimes foram fabricados em diferentes atmosferas (oxigénio; azoto). Na terceira os espécimes fabricados com os polivinilsiloxanos foram polidos com acetona ou borracha. A microdureza Knoop foi testada 24 horas após a polimerização. Os resultados foram analisados com Kruskal-Wallis e Mann-Whitney com correc¸ão de Bonferroni (alfa = 0,05). Resultados: Apenas nos grupos Bite-perf foi obtida microdureza semelhante (p > 0,05) à obtida com matriz de acetato. Nos espécimes fabricados com Memosil, Registrado e sem matriz a atmosfera de azoto permitiu obter microdureza mais elevada que com o oxigénio (p 0.05) to the mylar matrix group. In nitrogen, specimens from the groups with Memosil, Registrado and without matrix yielded significantly higher microhardness than the same groups in oxygen atmosphere (p < 0.05). After treatment of the superficial layer, microhardness was still lower than in the mylar matrix group (p < 0.05). Conclusions: Curing through the Bite-perf for 40 seconds the composite microhardness was similar to the one obtain after 20 seconds curing through the mylar matrix. Composite curing through the polyvinilsiloxanes lead to an inhibited oxygen layer that was not totally removed by the methods applied in this laboratory study.info:eu-repo/semantics/publishedVersio

    Ciências da computação de Alan Turing: Uma viagem pessoal

    Get PDF
    [Excerto] O moderno cientista da computação, interessado na correção dos seus artefatos, navega num terreno construído sobre as respostas a algumas questões fundamentais. Primeiro ele/ela pode perguntar “O que é demonstrável, refutável ou decidível?”, imediatamente seguido de “O que é inconsistente e o que pode ser validado?”. Mais ainda, é seguro dizer que, quando comparado com o âmbito do artefacto, ele/ela terá sobretudo que basear-se em respostas a outra questão “o que é que se pode aprender?”. Finalmente, quando o interesse se estende à segurança do artefacto e à privacidade do utilizador, o cenário é complicado por questões adicionais, nomeadamente “O que é aleatório? O que é obscuro e à prova de fuga, no sentido da teoria da informação?”. Através de toda a paisagem da Ciência e Engenharia da Computação (CEC) podem detetar-se as pegadas de Turing, algumas desmaiadas, mas outras muito claras e incisivas. Nesta breve monografia tentarei delinear algumas dessas pegadas, escolhendo aquelas que eu acredito serem as mais significativas para a minha visão da CEC. A questão que mais interessou Turing não foi nenhuma das anteriores mas antes O que é computável e, de entre essas ‘coisas computáveis’, o que é fazível? É bem conhecido o papel de Turing (Turing 1936; Soare 2016) na construção de uma resposta pelo menos à primeira parte da questão. A fazibilidade das computações veio mais tarde e é o domínio da Teoria da Complexidade; a sua importância e o papel de Turing foram reconhecidos há algum tempo (Hartmanis 1994). Algumas décadas antes, o início do Séc. XX viu o florescimento de novos fundamentos para o pensamento matemático: a axiomatização dos conjuntos de Zermelo-Fraenkel, construtivismo & intuicionismo e os problemas de decisão de Hilbert são alguns dos programas2 desta era; para além do seu impacto na matemática como um todo, estes programas tiveram um efeito direto nos fundamentos da CEC; de facto, podemos dizer que estes “são” três quartos dos fundamentos da CEC, o restante quarto sendo, obviamente, a computabilidade. [...

    Efeito do envelhecimento em ácido cítrico na microdureza e resistência à flexão de resinas compostas

    Get PDF
    Objetivos: Estudar a influência do envelhecimento em ácido cítrico na microdureza Vickers e resistência à flexão de três resinas compostas. Materiais e métodos: Foram fabricados 15 espécimes de cada um dos três compósitos microhíbridos estudados (1- Suprafil-R&S, 2- Proclinic-PM, 3- Tetric-EvoCeram). Após fotopolimerização, os espécimes foram aleatoriamente distribuídos por 3 esquemas de envelhecimento (A- imersão em H2O bi-destilada, pH = 6,6, durante 10 dias; B- imersão em H2O bi-destilada, pH = 6,6, durante as primeiras 24 h, seguindo-se 9 ciclos de 6 h em ácido cítrico pH = 2,5, alternados com 18 h em H2O bi-destilada pH = 6,6; C- 9 ciclos de imersão durante 6 h em ácido cítrico pH = 2,5 alternados com 18 h em H2O bi-destilada pH = 6,6, seguidos de imersão em H2O bi-destilada pH = 6,6 durante 24 h). Foram assim constituídos 9 grupos experimentais (n = 5), em que todos os espécimes sofreram um período total de envelhecimento de 10 dias, a 37 ◦C, após o qual foi realizado o ensaio de microdureza, imediatamente seguido do teste de resistência à flexão. Os valores obtidos foram analisados com ANOVA seguida de testes post-hoc segundo Student-Newman-Keuls. Resultados: Os espécimes submetidos ao esquema de envelhecimento C e os fabricados com o compósito Proclinic-PM apresentaram valores de microdureza estatisticamente (p < 0,05) mais baixos que os restantes. O esquema de envelhecimento não influenciou a resistência à flexão (p = 0,42), mas o compósito Suprafil-R&S obteve valores de resistência à flexão estatisticamente mais elevados que os restantes compósitos (p < 0,05). Conclusões: A exposição ao ácido cítrico imediatamente após a fotopolimerização influencia negativamente a microdureza do compósito, mas não tem influência sobre a resistência à flexão.Objectives: To evaluate the influence of citric acid aging on the microhardness and flexural strength of three composites resins. Materials and methods: 15 specimens of each microhybrid composite resin (1- Suprafil-R&S, 2- Proclinic-PM, 3- Tetric-EvoCeram) were prepared. After light curing specimens were randomly assigned to 3 protocols of aging (A- bi-distilled H2O pH = 6.6, immersion for 10 days; B- immersion for the first 24 h in bi-distilled H2O pH = 6.6, followed by 9 cycles of 6 h in citric acid pH = 2.5 interchanging with 18 h of bi-distilled H2O pH = 6.6; C- immersion for 6 h in citric acid pH = 2.5 interchanging with 18 h of bi-distilled H2O pH = 6.6, followed by 24 h immersion in bi-distilled H2O pH = 6.6). Therefore all the 9 experimental groups (n=5) were submitted to an ageing period of 10 days. The specimens were then submitted to Vickers microhardness test and flexural test. Data were analysed with ANOVA and Student-Newman-Keuls post-hoc test. Results: The scheme of aging C and the Proclinic-PM composite recorded statistically lower microhardness values (p<0,05) than the other. Flexural strength values were not influenced (p=0,42) by the scheme of aging, however Suprafil-R&S composite yielded statistically higher flexural strength values than the other composites (p<0,05). Conclusions: Exposure to citric acid immediately after light curing negatively influences the composite microhardness, but did not affect the flexural strength.info:eu-repo/semantics/publishedVersio

    Morphology of the dentin–resin interface yielded by twostep etch-and-rinse adhesives with different solvents

    No full text
    Aim: The study aimed to analyze the morphology of the dentin– resin interface yielded by two-step etch-and-rinse adhesive systems with different solvents and compositions. Materials and methods: A total of 32 dentine disks were prepared and randomly assigned to four groups of one-bottle etchand- rinse adhesive systems containing different solvents: group I, Adper Scotchbond-1XT™ (ethanol/water); group II, XP-Bond™ (tertiary butanol); group III, Prime and Bond NT® (acetone); and group IV, One Coat bond® (5% water). Adhesive systems were applied onto dentin disks, which were then thermal cycled, divided into two hemi-disks (n = 16), and prepared for field-emission scanning electron microscopy to examine the dentin–resin interdiffusion zone. Microphotographs were scanned and data were processed. Data were compared with analysis of variance multivariant test after Kolmogorov–Smirnov and Shapiro–Wilk tests using Statistic Package for the Social Sciences. Results: The adhesive layer thickness average found was group I: 45.9 ± 13.41 μm, group II: 20.6 ± 16.32 μm, group III: 17.7 ± 11.75 μm, and group IV: 50.7 ± 27.81 μm. Significant differences were found between groups I and IV and groups II and III (p<0.000). Groups I (3.23 ± 0.53 μm) and II (3.13 ± 0.73 μm) yielded significantly thicker hybrid layers than groups III (2.53 ± 0.50 μm) and IV (1.84 ± 0.27 μm) (p<0.003). Group III presented a less homogeneous hybrid layer, with some gaps. Tag length average was greater in groups II (111.0 ± 36.92 μm) and IV (128.9 ± 78.38 μm) than in groups I (61.5 ± 18.10 μm) and III (68.6 ± 15.84 μm) (p<0.008). Conclusion: Adhesives systems with different solvents led to significant differences in the dentin–resin interface morphology.info:eu-repo/semantics/publishedVersio
    corecore