1,495 research outputs found

    Barometric pumping of a fractured porous medium

    Get PDF
    International audienceBarometric pumping plays a crucial role in the release of trace gases from fractured porous media to the atmosphere, and it requires a rigorous and complete modeling in order to go beyond the approximate schemes available in the literature. Therefore, a coupled set of convection and convection-diffusion equations for a slightly compressible fluid in unsteady conditions should be solved. The numerical methodology is presented, and it is applied to conditions close to the ones of the Roselend Natural Laboratory (France). The precision of the code is assessed and the mechanism of barometric pumping is explained. The usual schematization by simple vertical fractures is shown to be only qualitative. Finally, barometric pumping is shown to be efficient in a narrow range of parameter values; its efficiency is a decreasing function of the matrix porosity and of the fracture density

    Phase-resolved magnetomotive OCT for imaging nanomolar concentrations of magnetic nanoparticles in tissues

    Get PDF
    Magnetic nanoparticles (MNPs) are increasingly important in magnetic resonance and biomedical optical imaging. We describe a method for imaging MNPs by detecting nanoscale displacements using a phaseresolved spectral-domain optical coherence tomography (OCT) system. Biological tissues and phantoms are exposed to ∼800 G magnetic fields modulated at 56 and 100 Hz to mechanically actuate embedded iron oxide MNPs (∼20 nm diameter). Sensitivity to 27 μg/g (∼2 nM) MNPs within tissue phantoms is achieved by filtering paramagnetic from diamagnetic vibrations. We demonstrate biological feasibility by imaging topically applied MNPs during their diffusion into an excised rat tumor over a 2 hour time period

    A comparative study of semiconductor-based plasmonic metamaterials

    Full text link
    Recent metamaterial (MM) research faces several problems when using metal-based plasmonic components as building blocks for MMs. The use of conventional metals for MMs is limited by several factors: metals such as gold and silver have high losses in the visible and near-infrared (NIR) ranges and very large negative real permittivity values, and in addition, their optical properties cannot be tuned. These issues that put severe constraints on the device applications of MMs could be overcome if semiconductors are used as plasmonic materials instead of metals. Heavily doped, wide bandgap oxide semiconductors could exhibit both a small negative real permittivity and relatively small losses in the NIR. Heavily doped oxides of zinc and indium were already reported to be good, low loss alternatives to metals in the NIR range. Here, we consider these transparent conducting oxides (TCOs) as alternative plasmonic materials for many specific applications ranging from surface-plasmon-polariton waveguides to MMs with hyperbolic dispersion and epsilon-near-zero (ENZ) materials. We show that TCOs outperform conventional metals for ENZ and other MM-applications in the NIR.Comment: 16 pages, 7 figure

    Magnetomotive nanoparticle transducers for optical rheology of viscoelastic materials

    Get PDF
    The availability of a real-time non-destructive modality to interrogate the mechanical properties of viscoelastic materials would facilitate many new investigations. We introduce a new optical method for measuring elastic properties of samples which employs magnetite nanoparticles as perturbative agents. Magnetic nanoparticles distributed in silicone-based samples are displaced upon probing with a small external magnetic field gradient and depth-resolved optical coherence phase shifts allow for the tracking of scatterers in the sample with nanometer-scale sensitivity. The scatterers undergo underdamped oscillations when the magnetic field is applied step-wise, allowing for the measurement of the natural frequencies of oscillation of the samples. Validation of the measurements is accomplished using a commercial indentation apparatus to determine the elastic moduli of the samples. This real-time non-destructive technique constitutes a novel way of probing the natural frequencies of viscoelastic materials in which magnetic nanoparticles can be introduced

    Optical micro-scale mapping of dynamic biomechanical tissue properties

    Get PDF
    Mechanical forces such as adhesion, shear stress and compression play crucial roles in tissue growth, patterning and development. To understand the role of these mechanical stimuli, it is of great importance to measure biomechanical properties of developing, engineered, and natural tissues. To enable these measurements on the micro-scale, a novel, dynamic, non-invasive, high-speed optical coherence elastography (OCE) system has been developed utilizing spectral-domain optical coherence tomography (OCT) and a mechanical wave driver. Experimental results of OCE on silicone phantoms are in good agreement with those obtained from a standardized indentation method. Using phase-resolved imaging, we demonstrate OCE can map dynamic elastic moduli of normal and neoplastic ex vivo human breast tissue with a sensitivity of 0.08%. Spatial micro-scale mapping of elastic moduli of tissue offers the potential for basic science and clinical investigations into the role biomechanics play in health and disease
    • …
    corecore