4,078 research outputs found

    Characterization of photomultiplier tubes in a novel operation mode for Secondary Emission Ionization Calorimetry

    Full text link
    Hamamatsu single anode R7761 and multi-anode R5900-00-M16 Photomultiplier Tubes have been characterized for use in a Secondary Emission (SE) Ionization Calorimetry study. SE Ionization Calorimetry is a novel technique to measure electromagnetic shower particles in extreme radiation environments. The different operation modes used in these tests were developed by modifying the conventional PMT bias circuit. These modifications were simple changes to the arrangement of the voltage dividers of the baseboard circuits. The PMTs with modified bases, referred to as operating in SE mode, are used as an SE detector module in an SE calorimeter prototype, and placed between absorber materials (Fe, Cu, Pb, W, etc.). Here, the technical design of different operation modes, as well as the characterization measurements of both SE modes and the conventional PMT mode are reported

    Mass distributions for nuclear disintegration from fission to evaporation

    Full text link
    By a proper choice of the excitation energy per nucleon we analyze the mass distributions of the nuclear fragmentation at various excitation energies. Starting from low energies (between 0.1 and 1 MeV/nucleon) up to higher energies about 12 MeV/n, we classified the mass yield characteristics for heavy nuclei (A>200) on the basis of Statistical Multifragmentation Model. The evaluation of fragment distribution with the excitation energy show that the present results exhibit the same trend as the experimental ones.Comment: 5 pages, 3 figure

    A rare cause of congenital portosystemic shunt: type 2 Abernethy malformation

    Get PDF
    The Abernethy malformation is characterised by congenital extrahepatic portosystemic shunts and is divided into two groups according to the type of anastomosis. In type 1, all portal venous blood is discharged into the inferior vena cava and there is no intrahepatic portal vein. In type 2, the portal vein is partially discharged to the inferior vena cava via side-by-side anastomoses. Imaging has an important role in the diagnosis and follow-up of this malformation. Magnetic resonance imaging should be preferred to demonstrate both vessel anatomy and associated anomalies. The aim of this study was to present a 17-year-old male patient and to discuss the imaging findings of Abernethy malformation

    Common coeliacomesenteric trunk: a computed tomography radiological study

    Get PDF
    Background: There is an increasing trend for administration of invasive radiological interventions, laparoscopic surgery, and transplantation procedures in recent years, and determining the vascular variations prior to these procedures is crucially important. Coeliacomesenteric trunk (CMT) is among these variations. This study aimed to retrospectively evaluate this rare anomaly by computed tomography (CT). Materials and methods: A total of 1000 CT angiography images were analysed retrospectively, and the patients with mesenteric and coeliac arteries arising from the abdominal aorta with a single root were identified. The level that CMT arose, and its branching patterns were determined individually for all patients. Results: Ten patients (6 males and 4 females) with a mean age of 50.2 years (17–87 years) had CMT in CT images. Conclusions: The knowledge of variations in the CMT prior to vascular or laparoscopic interventions will contribute to early intervention in case of a complication, or to avoid from a potential damage

    The utility of multidetector computed tomography for evaluation of congenital heart disease

    Get PDF
    Background: Congenital heart diseases (CHD) are the leading cause of birthdefect-related deaths. Multidedector computed tomography (MDCT) plays animportant role for imaging CHD in addition to echocardiography and providesa comprehensive evaluation of complex heart malformations for the referringcardiologist. The aim of the study was to evaluate the utility of MDCT in theassessment of CHD.Materials and methods: A 102 patients with CHD were investigated after initialassessment by echocardiography. The information obtained by MDCT and findingsof echocardiography were reviewed together by paediatric cardiologistsand cardiac radiologists. Perioperative anatomic descriptions, wherever available(n = 34) formed the gold standard for the comparison.Results: The clinical consensus diagnosis defined 154 cardiovascular lesions inthe patients. The results were classified in groups. We present the appearanceof various congenital cardiac lesions seen in clinical practice.Conclusions: MDCT provides important information about anatomic details ofCHD for the referring cardiologist. The evaluation of different anatomic structuressuch as heart, great vessels, lungs and abdomen is possible in one acquisitionwith this technique

    Isospin dependent multifragmentation of relativistic projectiles

    Full text link
    The N/Z dependence of projectile fragmentation at relativistic energies has been studied with the ALADIN forward spectrometer at the GSI Schwerionen Synchrotron (SIS). Stable and radioactive Sn and La beams with an incident energy of 600 MeV per nucleon have been used in order to explore a wide range of isotopic compositions. For the interpretation of the data, calculations with the statistical multifragmentation model for a properly chosen ensemble of excited sources were performed. The parameters of the ensemble, representing the variety of excited spectator nuclei expected in a participant-spectator scenario, are determined empirically by searching for an optimum reproduction of the measured fragment-charge distributions and correlations. An overall very good agreement is obtained. The possible modification of the liquid-drop parameters of the fragment description in the hot freeze-out environment is studied, and a significant reduction of the symmetry-term coefficient is found necessary to reproduce the mean neutron-to-proton ratios /Z and the isoscaling parameters of Z<=10 fragments. The calculations are, furthermore, used to address open questions regarding the modification of the surface-term coefficient at freeze-out, the N/Z dependence of the nuclear caloric curve, and the isotopic evolution of the spectator system between its formation during the initial cascade stage of the reaction and its subsequent breakup.Comment: 23 pages, 29 figures, published in Physical Review
    corecore