284 research outputs found

    Closed-cycle, low-vibration 4 K cryostat for ion traps and other applications

    Get PDF
    In-vacuo cryogenic environments are ideal for applications requiring both low temperatures and extremely low particle densities. This enables reaching long storage and coherence times for example in ion traps, essential requirements for experiments with highly charged ions, quantum computation, and optical clocks. We have developed a novel cryostat continuously refrigerated with a pulse-tube cryocooler and providing the lowest vibration level reported for such a closed-cycle system with 1 W cooling power for a <5 K experiment. A decoupling system suppresses vibrations from the cryocooler by three orders of magnitude down to a level of 10 nm peak amplitudes in the horizontal plane. Heat loads of about 40 W (at 45 K) and 1 W (at 4 K) are transferred from an experimental chamber, mounted on an optical table, to the cryocooler through a vacuum-insulated massive 120 kg inertial copper pendulum. The 1.4 m long pendulum allows installation of the cryocooler in a separate, acoustically isolated machine room. In the laser laboratory, we measured the residual vibrations using an interferometric setup. The positioning of the 4 K elements is reproduced to better than a few micrometer after a full thermal cycle to room temperature. Extreme high vacuum on the 101510^{-15} mbar level is achieved. In collaboration with the Max-Planck-Intitut f\"ur Kernphysik (MPIK), such a setup is now in operation at the Physikalisch-Technische Bundesanstalt (PTB) for a next-generation optical clock experiment using highly charged ions

    Alternative antibody for the detection of CA19-9 antigen: a European multicenter study for the evaluation of the analytical and clinical performance of the Access (R) GI Monitor assay on the UniCel (R) Dxl 800 Immunoassay System

    Get PDF
    Background: Gastrointestinal cancer antigen CA19-9 is known as a valuable marker for the management of patients with pancreatic cancer. Methods: The analytical and clinical performance of the Access(R) GI Monitor assay (Beckman Coulter) was evaluated on the UniCel(R) Dxl 800 Immunoassay System at five different European sites and compared with a reference method, defined as CA19-9 on the Elecsys System (Roche Diagnostics). Results: Total imprecision (%CV) of the GI Monitor ranged between 3.4% and 7.7%, and inter-laboratory reproducibility between 3.6% and 4.0%. Linearity upon dilution showed a mean recovery of 97.4% (SD+7.2%). Endogenous interferents had no influence on GI Monitor levels (mean recoveries: hemoglobin 103%, bilirubin 106%, triglycerides 106%). There was no high-dose hook effect up to 115,000 kU/L. Clinical performance investigated in sera from 1811 individuals showed a good correlation between the Access' GI Monitor and Elecsys CA19-9 (R = 0.959, slope = 1.004, intercept +0.17). GI Monitor serum levels were low in healthy individuals (n = 267, median = 6.0 kU/L, 95th percentile = 23.1 kU/L), higher in individuals with various benign diseases (n = 550, medians = 5.8-13.4 kU/L, 95th percentiles = 30.1-195.5 kU/L) and even higher in individuals suffering from various cancers (n = 995, medians = 8.4-233.8 kU/L, 95th percentiles = 53.7-13,902 kU/L). Optimal diagnostic accuracy for cancer detection against the relevant benign control group by the GI Monitor was found for pancreatic cancer {[}area under the curve (AUC) 0.83]. Results for the reference CA19-9 assay were comparable (AUC 0.85). Conclusions: The Access(R) GI Monitor provides very good methodological characteristics and demonstrates an excellent analytical and clinical correlation with the Elecsys CA19-9. The GI Monitor shows the best diagnostic accuracy in pancreatic cancer. Our results also suggest a clinical value of the GI Monitor in other cancers

    Serum CA19-9 response as a surrogate for clinical outcome in patients receiving fixed-dose rate gemcitabine for advanced pancreatic cancer

    Get PDF
    The use of serial serum measurements of the carbohydrate antigen 19-9 (CA19-9) to guide treatment decisions and serve as a surrogate end point in clinical trial design requires further validation. We investigated whether CA19-9 decline represents an accurate surrogate for survival and time to treatment failure (TTF) in a cohort of 76 patients with advanced pancreatic cancer receiving fixed-dose rate gemcitabine in three separate studies. Statistically significant correlations between percentage CA19-9 decline and both overall survival and TTF were found, with median survival ranging from 12.0 months for patients with the greatest degree of biomarker decline (>75%) compared with 4.3 months in those whose CA19-9 did not decline during therapy (P<0.001). Using specific thresholds, patients with ⩾25% decline in CA19-9 during treatment had significantly better outcomes than those who did not (median survival and TTF of 9.6 and 4.6 months vs 4.4 and 1.5 months; P<0.001). Similar results were seen using both 50 and 75% as cutoff points. We conclude that serial CA19-9 measurements correlate well with clinical outcomes in this patient population, and that decline in this biomarker should be entertained for possible use as a surrogate end point in clinical trials for the selection of new treatments in this disease

    Radiotherapy in langerhans cell histiocytosis - a rare indication in a rare disease

    Full text link
    Introduction: Langerhans Cell Histiocytosis (LCH) represents a rare benign disorder, previously designated as “Histiocytosis X”, “Type II Histiocytosis” or “Langerhans Cell Granulomatosis”. Clinical presentation includes osteolysis, ulcerations of skin and soft tissues but also involvement of the CNS is described. Because treatment concepts are not well defined the German Cooperative Group on Radiotherapy for Benign Diseases performed a retrospective analysis. Methods and material: Eight closely cooperating centres collected patients’ data of the past 45 years. As study endpoints disease free survival, recurrent disease, death and therapy related side effects were defined. Results: A total of 80 patients with histologically proven LCH were irradiated within the past 45 years. According to the LCH classification of Greenberger et al. 37 patients had stage Ia, 21 patients stage Ib, 13 patients stage II and 9 patients stage IIIb and the median age was 29 years. The median Follow up was 54 months (range 9–134 months). A total of 39 patients had a surgical intervention and 23 patients a chemotherapy regimen. Radiation treatment was carried out with a median total dose of 15 Gy (range 3–50.4 Gy). The median single fraction was 2 Gy (range 1.8-3 Gy). Overall, 77% patients achieved a complete remission and 12.5% achieved a partial remission. The long-term control rate reached 80%. Within an actuarial overall 5-year survival of 90% no radiogenic side and late effects ≥EORTC/RTOG II° were observed. Conclusion: In the present study a large collective of irradiated patients was analysed. Radiotherapy (RT) is a very effective and safe treatment option and even low RT doses show sufficient local control.<br

    Importance of Magnesium Status in COVID-19

    Get PDF
    A large amount of published research points to the interesting concept (hypothesis) that magnesium (Mg) status may have relevance for the outcome of COVID-19 and that Mg could be protective during the COVID disease course. As an essential element, Mg plays basic biochemical, cellular, and physiological roles required for cardiovascular, immunological, respiratory, and neurological functions. Both low serum and dietary Mg have been associated with the severity of COVID-19 outcomes, including mortality; both are also associated with COVID-19 risk factors such as older age, obesity, type 2 diabetes, kidney disease, cardiovascular disease, hypertension, and asthma. In addition, populations with high rates of COVID-19 mortality and hospitalization tend to consume diets high in modern processed foods, which are generally low in Mg. In this review, we review the research to describe and consider the possible impact of Mg and Mg status on COVID-19 showing that (1) serum Mg between 2.19 and 2.26 mg/dL and dietary Mg intakes &gt; 329 mg/day could be protective during the disease course and (2) inhaled Mg may improve oxygenation of hypoxic COVID-19 patients. In spite of such promise, oral Mg for COVID-19 has thus far been studied only in combination with other nutrients. Mg deficiency is involved in the occurrence and aggravation of neuropsychiatric complications of COVID-19, including memory loss, cognition, loss of taste and smell, ataxia, confusion, dizziness, and headache. Potential of zinc and/or Mg as useful for increasing drug therapy effectiveness or reducing adverse effect of anti-COVID-19 drugs is reviewed. Oral Mg trials of patients with COVID-19 are warranted

    An Optical Atomic Clock Based on a Highly Charged Ion

    Full text link
    Optical atomic clocks are the most accurate measurement devices ever constructed and have found many applications in fundamental science and technology. The use of highly charged ions (HCI) as a new class of references for highest accuracy clocks and precision tests of fundamental physics has long been motivated by their extreme atomic properties and reduced sensitivity to perturbations from external electric and magnetic fields compared to singly charged ions or neutral atoms. Here we present the first realisation of this new class of clocks, based on an optical magnetic-dipole transition in Ar13+^{13+}. Its comprehensively evaluated systematic frequency uncertainty of 2.2×10172.2\times10^{-17} is comparable to that of many optical clocks in operation. From clock comparisons we improve by eight and nine orders of magnitude upon the uncertainties for the absolute transition frequency and isotope shift (40^{40}Ar vs. 36^{36}Ar), respectively. These measurements allow us to probe the largely unexplored quantum electrodynamic nuclear recoil, presented as part of improved calculations of the isotope shift which reduce the uncertainty of previous theory by a factor of three. This work establishes forbidden optical transitions in HCI as references for cutting-edge optical clocks and future high-sensitivity searches for physics beyond the standard model.Comment: Main: 20 pages, 3 figures. Supplement: 19 pages, 2 figure
    corecore