4,961 research outputs found

    A preliminary case study of the effect of shoe-wearing on the biomechanics of a horse’s foot

    Get PDF
    Horse racing is a multi-billion-dollar industry that has raised welfare concerns due to injured and euthanized animals. Whilst the cause of musculoskeletal injuries that lead to horse morbidity and mortality is multifactorial, pre-existing pathologies, increased speeds and substrate of the racecourse are likely contributors to foot disease. Horse hooves have the ability to naturally deform during locomotion and dissipate locomotor stresses, yet farriery approaches are utilised to increase performance and protect hooves from wear. Previous studies have assessed the effect of different shoe designs on locomotor performance; however, no biomechanical study has hitherto measured the effect of horseshoes on the stresses of the foot skeleton in vivo. This preliminary study introduces a novel methodology combining three-dimensional data from biplanar radiography with inverse dynamics methods and finite element analysis (FEA) to evaluate the effect of a stainless steel shoe on the function of a Thoroughbred horse's forefoot during walking. Our preliminary results suggest that the stainless steel shoe shifts craniocaudal, mediolateral and vertical GRFs at mid-stance. We document a similar pattern of flexion-extension in the PIP (pastern) and DIP (coffin) joints between the unshod and shod conditions, with slight variation in rotation angles throughout the stance phase. For both conditions, the PIP and DIP joints begin in a flexed posture and extend over the entire stance phase. At mid-stance, small differences in joint angle are observed in the PIP joint, with the shod condition being more extended than the unshod horse, whereas the DIP joint is extended more in the unshod than the shod condition. We also document that the DIP joint extends more than the PIP after midstance and until the end of the stance in both conditions. Our FEA analysis, conducted solely on the bones, shows increased von Mises and Maximum principal stresses on the forefoot phalanges in the shod condition at mid-stance, consistent with the tentative conclusion that a steel shoe might increase mechanical loading. However, because of our limited sample size none of these apparent differences have been tested for statistical significance. Our preliminary study illustrates how the shoe may influence the dynamics and mechanics of a Thoroughbred horse's forefoot during slow walking, but more research is needed to quantify the effect of the shoe on the equine forefoot during the whole stance phase, at faster speeds/gaits and with more individuals as well as with a similar focus on the hind feet. We anticipate that our preliminary analysis using advanced methodological approaches will pave the way for new directions in research on the form/function relationship of the equine foot, with the ultimate goal to minimise foot injuries and improve animal health and welfare

    Graphene as a Novel Single Photon Counting Optical and IR Photodetector

    Full text link
    Bilayer graphene has many unique optoelectronic properties , including a tuneable band gap, that make it possible to develop new and more efficient optical and nanoelectronic devices. We have developed a Monte Carlo simulation for a single photon counting photodetector incorporating bilayer graphene. Our results show that, conceptually it would be feasible to manufacture a single photon counting photodetector (with colour sensitivity) from bilayer graphene for use across both optical and infrared wavelengths. Our concept exploits the high carrier mobility and tuneable band gap associated with a bilayer graphene approach. This allows for low noise operation over a range of cryogenic temperatures, thereby reducing the cost of cryogens with a trade off between resolution and operating temperature. The results from this theoretical study now enable us to progress onto the manufacture of prototype photon counters at optical and IR wavelengths that may have the potential to be groundbreaking in some scientific research applications.Comment: Conference Proceeding in Graphene-Based Technologies, 201

    Musculoskeletal Geometry, Muscle Architecture and Functional Specialisations of the Mouse Hindlimb

    Get PDF
    Mice are one of the most commonly used laboratory animals, with an extensive array of disease models in existence, including for many neuromuscular diseases. The hindlimb is of particular interest due to several close muscle analogues/homologues to humans and other species. A detailed anatomical study describing the adult morphology is lacking, however. This study describes in detail the musculoskeletal geometry and skeletal muscle architecture of the mouse hindlimb and pelvis, determining the extent to which the muscles are adapted for their function, as inferred from their architecture. Using I2KI enhanced microCT scanning and digital segmentation, it was possible to identify 39 distinct muscles of the hindlimb and pelvis belonging to nine functional groups. The architecture of each of these muscles was determined through microdissections, revealing strong architectural specialisations between the functional groups. The hip extensors and hip adductors showed significantly stronger adaptations towards high contraction velocities and joint control relative to the distal functional groups, which exhibited larger physiological cross sectional areas and longer tendons, adaptations for high force output and elastic energy savings. These results suggest that a proximo-distal gradient in muscle architecture exists in the mouse hindlimb. Such a gradient has been purported to function in aiding locomotor stability and efficiency. The data presented here will be especially valuable to any research with a focus on the architecture or gross anatomy of the mouse hindlimb and pelvis musculature, but also of use to anyone interested in the functional significance of muscle design in relation to quadrupedal locomotion

    Regional variation in digital cushion pressure in the forefeet of horses and elephants

    Get PDF
    In this study, we seek to understand how the digital cushion morphologies evident in horse and elephant feet influence internal and external foot pressures. Our novel use of invasive blood pressure monitoring equipment, combined with a pressure pad and force plate, enabled measurements of (ex vivo) digital cushion pressure under increasing axial loads in seven horse and six elephant forefeet. Linear mixed effects models (LMER) revealed that internal digital cushion pressures increase under load and differ depending on region; elephant feet experienced higher magnitudes of medial digital cushion pressure, whereas horse feet experienced higher magnitudes of centralised digital cushion pressure. Direct comparison of digital cushion pressure magnitudes in both species, at equivalent loads relative to body weight, revealed that medial and lateral pressures increased more rapidly with load in elephant limbs. Within the same approximate region, internal pressures exceeded external, palmar pressures (on the sole of the foot), supporting previous Finite Element (FE) predictions. High pressures and large variations in pressure may relate to the development of foot pathology, which is a major concern in horses and elephants in a captive/domestic environment

    TOKENIZATION TICKET MASTER

    Get PDF
    The present invention discloses a tokenization ticket master system where in which a consumer 101 enters sensitive data into an event checkout page which is displayed/presented on a user device 102. The event checkout page presented/displayed on the user device 102 posts the sensitive data to an event server 103. The sensitive data is then sent to a tokenization server 104, where the data is securely stored, and a token is created to represent the sensitive data. A token ID is returned to the event server 103 and the token ID is encoded as a QR code. The token may be generated using, but not limited to Universally Unique Identifier (UUID). The event server and the tokenization server may interact via Application Program Interface (API). In one embodiment, the QR code is displayed to the consumer 101 on a receipt page on the user device 102. The consumer 101 may print the QR code with a QR printer 105 or may save the QR code as a digital file in the user device 102. In an embodiment, known techniques can be used to generate the QR code

    Designing a new molecular probe : the potential role for Tilmanocept (Lymphoseek) in the assessment of patients with painful hip and knee joint prostheses

    Get PDF
    There is a long history of nuclear medicine developments in orthopaedics beginning in the early 20th century. Technetium-99m (99mTc) has a short half-life of six hours, emits 140 keV gamma rays and is the most widely used isotope, imaged with the Anger (gamma) camera. Gamma image quality and test sensitivity in painful prosthetic joints can be improved with single photon emission computed tomography (SPECT) and SPECT/CT. Positron Emission Tomography-Computed Tomography (PET-CT) with Sodium Fluoride (18F-NaF) and 18Fluorine-fluorodeoxyglucose (18F-FDG) PET have promising and limited roles respectively in the investigation of painful prosthetic joints. New SPECT/CT and PET-CT isotopes targeting activated macrophages with 99mTc Tilmanocept (Lymphoseek®) and 68Gallium labelled Tilmanocept respectively show potential as agents to demonstrate wear particles ingested by macrophages and multinucleated giant cells. An imaging algorithm using SPECT and/or PET agents is proffered as a cost effective way of speedily and accurately arriving a diagnosis. Methods: Review of the historical role of nuclear medicine in orthopaedics and research into the potential role of new radiopharmaceutical agents was undertaken. Guidelines and algorithms for the imaging of complicated joint prosthesis are provided. Results: There is an established role for nuclear medicine in orthopaedics and particularly in the investigation of complicated joint prostheses. Imaging with Tilmanocept provides new opportunities to shorten the time to diagnose loosened and infected joint prostheses. Conclusion: There is a potential new role for Tilmanocept, which can be utilised with both PET-CT and SPECT-CT technologies. Tilmanocept is a relatively new radiopharmaceutical which has a potential role in the imaging assessment of painful joint prosthesis

    Decrease in health-related quality of life associated with awareness of hepatitis C virus infection among people who inject drugs in Scotland

    Get PDF
    Chronic hepatitis C virus (HCV) infection can significantly reduce health-related quality of life (QoL), but it is not clear if reduction is associated with the infection or with being aware of one's infection status. Understanding the impact of a HCV diagnosis on QoL is essential to inform decision-making regarding screening/testing and treatment. Using a cross-sectional design, we assessed QoL in 2898 people who inject drugs (PWID), surveyed in Scotland during 2010 using EQ-5D. Multifactorial regression compared self-reported QoL between PWID who were (i) chronically HCV-infected and aware of their infected status, (ii) chronically HCV-infected but unaware, and (iii) not chronically infected. Median time since onset of injecting was 10years; not chronically infected PWID were younger and had shorter injecting careers than chronically infected PWID. Median EQ-5D was highest for the not chronically infected and the chronic/unaware groups (0.73) compared with the chronic/aware group (0.66). After adjustment for demographic and behavioural co-factors, QoL was significantly reduced in chronic/aware compared with chronic/unaware PWID (adjusted B=-0.09, p=0.005); there was no evidence for a difference in QoL between not chronically infected and chronic/unaware PWID (adjusted B=-0.03, p=0.13). Awareness of one's chronic HCV status was associated with reduced health-related QoL, but there was no evidence for further reduction attributable to chronic infection itself after adjusting for important covariate differences

    Executive Summary: Young people, education, employment and ESOL

    Get PDF
    The report, ‘Young people, education, employment and ESOL’ reviewed 47 studies1 to examine how current ESOL provision2 meets the needs of young people aged 16-25 years who use English as an Additional Language (EAL)3, and who need time and support to develop their English language skills in order to progress in education, training and employment
    corecore