55 research outputs found
A simple opto-fluidic switch detecting liquid filling in polymer-based microfluidic systems
A novel detection scheme for detection of liquid levels and bubbles in microfluidic systems, using the principle of total internal reflection (TIR) is presented. A laser beam impinges on the side walls of a channel which are inclined at 45deg. In an unfilled channel of such a "V-groove", TIR deflects the beam by 90deg into a simple light detector. Upon the presence of liquid, the refractive index in the channel changes, thus eliminating deflection by TIR. The detection principle is robust, requiring no calibration, and tolerating alignment errors of the laser larger than the width and depth of the microfluidic channels. The machining of the V-groves can seamlessly be integrated into common polymer microfabrication schemes such as injection molding
Mass and charge transport in micro and nano-fluidic channels
We consider laminar flow of incompressible electrolytes in long, straight
channels driven by pressure and electro-osmosis. We use a Hilbert space
eigenfunction expansion to address the general problem of an arbitrary cross
section and obtain general results in linear-response theory for the mass and
charge transport coefficients which satisfy Onsager relations. In the limit of
non-overlapping Debye layers the transport coefficients are simply expressed in
terms of parameters of the electrolyte as well as the hydraulic radius R=2A/P
with A and P being the cross-sectional area and perimeter, respectively. In
articular, we consider the limits of thin non-overlapping as well as strongly
overlapping Debye layers, respectively, and calculate the corrections to the
hydraulic resistance due to electro-hydrodynamic interactions.Comment: Invited paper presented at the Second International Conference on
Transport Phenomena in Micro and Nanodevices, Il Ciocco Hotel and Conference
Center, Barga, Italy, 11-15 June 2006. Accepted for publication in a special
issue of Nanoscale and Microscale Thermophysical Engineering (Taylor &
Francis
Transport coefficients for electrolytes in arbitrarily shaped nano and micro-fluidic channels
We consider laminar flow of incompressible electrolytes in long, straight
channels driven by pressure and electro-osmosis. We use a Hilbert space
eigenfunction expansion to address the general problem of an arbitrary cross
section and obtain general results in linear-response theory for the hydraulic
and electrical transport coefficients which satisfy Onsager relations. In the
limit of non-overlapping Debye layers the transport coefficients are simply
expressed in terms of parameters of the electrolyte as well as the geometrical
correction factor for the Hagen-Poiseuille part of the problem. In particular,
we consider the limits of thin non-overlapping as well as strongly overlapping
Debye layers, respectively, and calculate the corrections to the hydraulic
resistance due to electro-hydrodynamic interactions.Comment: 13 pages including 4 figures and 1 table. Typos corrected. Accepted
for NJ
Paired emitter-detector diode detection with dual wavelength monitoring for enhanced sensitivity to transition metals in ion chromatography with post-column reaction
The combination of post-column derivatisation and visible detection are regularly employed in ion chromatography (IC) to detect poorly absorbing species. Although this mode is often highly sensitive, one disadvantage is the increase in repeating baseline artifacts associated with out-of-sync pumping systems. The work presented here will demonstrate the use of a second generation design paired emitter-detector diode (PEDD-II) detection mode offering enhanced sensitivity to transition metals in IC by markedly reducing this problem and also by improving signal noise. First generation designs demonstrated the use of a single integrated PEDD detector cell as a simple, small (15 x 5 mm), highly sensitive, low cost photometric detector for the detection of metals in ion chromatography (IC). The basic principle of this detection mode lies in the employment of two linear light emitting diodes (LEDs), one operating in normal mode as a light source and the other in reverse bias serving as a light detector.
The second generation PEDD-II design showed increased sensitivity for Mn(II)- and Co(II)-2-(pyridylazo) resorcinol (PAR) complexes as a result of two simultaneously acquiring detection cells - one analytical PEDD cell and one reference PEDD cell. Therefore, the PEDD-II employs two wavelengths whereby one monitors the analyte reaction product and the second monitors a wavelength close to the isosbestic point. The optimum LED wavelength to be used for the analytical cell was investigated to maximise peak response. The fabrication process for both the analytical and reference PEDD cells was validated by determining the reproducibility of detectors within a batch. The reproducibility and sensitivity of the PEDD-II detector was then investigated using signals obtained from both intra- and inter-day chromatograms
Determination of phosphate using a highly sensitive paired emitter-detector diode photometric flow detector
The use of a novel inexpensive photometric device, Paired Emitter Detector Diode (PEDD) has been applied to the colorimetric determination of phosphate using the malachite green spectrophotometric method. The novel miniaturized flow detector applied within this manifold is a highly sensitive, low cost, miniaturized light emitting diode (LED) based detector. The optical flow cell was constructed from two LEDs, whereby one is the light source and the second is the light detector, with the LED light source forward biased and the LED detector reversed biased. The photocurrent generated by the LED light source discharges the junction capacitance of the detector diode from 5 V (logic 1) to 1.7 V (logic 0) and the time taken for this process to occur is measured using a simple timer circuit.
The malachite green (MG) method employed for phosphate determination is based on the formation of a green molybdophosphoric acid complex, the intensity of which is directly related to phosphate concentration. Optimum analytical parameters such as reaction kinetics, reagent to sample concentration ratio and emitter wavelength intensity were investigated for the spectrophotometric method. Linear calibration plots that obeyed the Beer-Lambert Law were obtained for phosphate in the range of 0.02-2 ”M. The dynamic range, sensitivity and limits of detection are reported
Modular microfluidic system as a model of cystic fibrosis airways
A modular microfluidic airways model system that can simulate the changes in oxygen tension in different compartments of the cystic fibrosis (CF) airways was designed, developed, and tested. The fully reconfigurable system composed of modules with different functionalities: multichannel peristaltic pumps, bubble traps, gas exchange chip, and cell culture chambers. We have successfully applied this system for studying the antibiotic therapy of Pseudomonas aeruginosa, the bacteria mainly responsible for morbidity and mortality in cystic fibrosis, in different oxygen environments. Furthermore, we have mimicked the bacterial reinoculation of the aerobic compartments (lower respiratory tract) from the anaerobic compartments (cystic fibrosis sinuses) following an antibiotic treatment. This effect is hypothesised as the one on the main reasons for recurrent lung infections in cystic fibrosis patients
Revival of the magnetar PSR J1622-4950: observations with MeerKAT, Parkes, XMM-Newton, Swift, Chandra, and NuSTAR
New radio (MeerKAT and Parkes) and X-ray (XMM-Newton, Swift, Chandra, and
NuSTAR) observations of PSR J1622-4950 indicate that the magnetar, in a
quiescent state since at least early 2015, reactivated between 2017 March 19
and April 5. The radio flux density, while variable, is approximately 100x
larger than during its dormant state. The X-ray flux one month after
reactivation was at least 800x larger than during quiescence, and has been
decaying exponentially on a 111+/-19 day timescale. This high-flux state,
together with a radio-derived rotational ephemeris, enabled for the first time
the detection of X-ray pulsations for this magnetar. At 5%, the 0.3-6 keV
pulsed fraction is comparable to the smallest observed for magnetars. The
overall pulsar geometry inferred from polarized radio emission appears to be
broadly consistent with that determined 6-8 years earlier. However, rotating
vector model fits suggest that we are now seeing radio emission from a
different location in the magnetosphere than previously. This indicates a novel
way in which radio emission from magnetars can differ from that of ordinary
pulsars. The torque on the neutron star is varying rapidly and unsteadily, as
is common for magnetars following outburst, having changed by a factor of 7
within six months of reactivation.Comment: Published in ApJ (2018 April 5); 13 pages, 4 figure
Revival of the Magnetar PSR J1622-4950: Observations with MeerKAT, Parkes, XMM-Newton, Swift, Chandra, and NuSTAR
New radio (MeerKAT and Parkes) and X-ray (XMM-Newton, Swift, Chandra, and NuSTAR) observations of PSR J1622-4950 indicate that the magnetar, in a quiescent state since at least early 2015, reactivated between 2017 March 19 and April 5. The radio flux density, while variable, is approximately 100 larger than during its dormant state. The X-ray flux one month after reactivation was at least 800 larger than during quiescence, and has been decaying exponentially on a 111 19 day timescale. This high-flux state, together with a radio-derived rotational ephemeris, enabled for the first time the detection of X-ray pulsations for this magnetar. At 5%, the 0.3-6 keV pulsed fraction is comparable to the smallest observed for magnetars. The overall pulsar geometry inferred from polarized radio emission appears to be broadly consistent with that determined 6-8 years earlier. However, rotating vector model fits suggest that we are now seeing radio emission from a different location in the magnetosphere than previously. This indicates a novel way in which radio emission from magnetars can differ from that of ordinary pulsars. The torque on the neutron star is varying rapidly and unsteadily, as is common for magnetars following outburst, having changed by a factor of 7 within six months of reactivation
- âŠ