1,185 research outputs found

    Functional vision barriers: a new concept analyzed in terms of human visual performance

    Get PDF
    In this work we introduce a new category of barriers that we call "functional vision barriers." This expression refers to lighting and visual elements that may complicate or hinder functional vision and may make life even more difficult for people with visual defects. These barriers appear as a consequence of certain negative effects caused by the poor design of the visual stimulus or visual environment that surrounds it in which lighting is one of the main factors. We use the term "functional vision" because this expression refers to the ability of the visual system to perform everyday tasks. We analyzed some of our previous results with regard to situations that can be considered "functional vision barriers": (1) stimuli with low luminance contrast information in which the addition of chromatic contrast improves visual performance and (2) tasks that are performed in the presence of a glare source in the visual field, diminishing visual performance and reducing brightness perception.Fil: Colombo, Elisa Margarita. Universidad Nacional de Tucuman. Facultad de Cs.exactas y Tecnologia. Departamento de Luminotecnia, Luz y Vision; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucuman. Instituto de Investigacion En Luz, Ambiente y Vision; ArgentinaFil: O´Donell, Beatriz M.. Universidad Nacional de Tucuman. Facultad de Cs.exactas y Tecnologia. Departamento de Luminotecnia, Luz y Vision; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucuman. Instituto de Investigacion En Luz, Ambiente y Vision; ArgentinaFil: Santillán, Javier Enrique. Universidad Nacional de Tucuman. Facultad de Cs.exactas y Tecnologia. Departamento de Luminotecnia, Luz y Vision; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucuman. Instituto de Investigacion En Luz, Ambiente y Vision; ArgentinaFil: Issolio, Luis Alberto. Universidad Nacional de Tucuman. Facultad de Cs.exactas y Tecnologia. Departamento de Luminotecnia, Luz y Vision; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucuman. Instituto de Investigacion En Luz, Ambiente y Vision; Argentin

    Color discrimination is affected by modulation of luminance noise in pseudoisochromatic stimuli

    Get PDF
    Pseudoisochromatic stimuli have been widely used to evaluate color discrimination and to identify color vision deficits. Luminance noise is one of the stimulus parameters used to ensure that subject´s response is due to their ability to discriminate target stimulus from the background based solely on the hue between the colors that compose such stimuli. We studied the influence of contrast modulation of the stimulus luminance noise on threshold and reaction time color discrimination. We evaluated color discrimination thresholds using the Cambridge Color Test (CCT) at six different stimulus mean luminances. Each mean luminance condition was tested using two protocols: constant absolute difference between maximum and minimum luminance of the luminance noise (constant delta protocol, CDP), and constant contrast modulation of the luminance noise (constant contrast protocol, CCP). MacAdam ellipses were fitted to the color discrimination thresholds in the CIE 1976 color space to quantify the color discrimination ellipses at threshold level. The same CDP and CCP protocols were applied in the experiment measuring RTs at three levels of stimulus mean luminance. The color threshold measurements show that for the CDP, ellipse areas decreased as a function of the mean luminance and they were significantly larger at the two lowest mean luminances, 10 cd/m2 and 13 cd/m2, compared to the highest one, 25 cd/m2. For the CCP, the ellipses areas also decreased as a function of the mean luminance, but there was no significant difference between ellipses areas estimated at six stimulus mean luminances. The exponent of the decrease of ellipse areas as a function of stimulus mean luminance was steeper in the CDP than CCP. Further, reaction time increased linearly with the reciprocal of the length of the chromatic vectors varying along the four chromatic half-axes. It decreased as a function of stimulus mean luminance in the CDP but not in the CCP. The findings indicated that visual performance using pseudoisochromatic stimuli was dependent on the Weber´s contrast of the luminance noise. Low Weber´s contrast in the luminance noise is suggested to have a reduced effect on chromatic information and, hence, facilitate desegregation of the hue-defined target from the background.Fil: Cormenzana Méndez, Iñaki. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Laboratorio de Luminotecnia; ArgentinaFil: Martín, Andrés. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Laboratorio de Luminotecnia; ArgentinaFil: Charmichael, Teaire L.. Christian Brothers University; Estados UnidosFil: Jacob, Mellina M.. Universidade Federal do Pará; BrasilFil: Lacerda, Eliza M. C. B.. Universidade Federal do Pará; BrasilFil: Gomes, Bruno D.. Universidade Federal do Pará; BrasilFil: Fitzgerald, Malinda E. C.. Christian Brothers University; Estados Unidos. University of Tennessee; Estados UnidosFil: Ventura, Dora F.. Universidade de Sao Paulo; BrasilFil: Silveira, Luiz C. L.. Universidade do Ceuma; Brasil. Universidade Federal do Pará; BrasilFil: O´donell, Beatriz Maria. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Laboratorio de Luminotecnia; ArgentinaFil: Souza, Givago S.. Universidade Federal do Pará; Brasi

    Patient-directed self-management of pain (PaDSMaP) compared to treatment as usual following total knee replacement; a randomised controlled trial

    Get PDF
    Background Self-administration of medicines by patients whilst in hospital is being increasingly promoted despite little evidence to show the risks and benefits. Pain control after total knee replacement (TKR) is known to be poor. The aim of the study was to determine if patients operated on with a TKR who self-medicate their oral analgesics in the immediate post-operative period have better pain control than those who receive their pain control by nurse-led drug rounds (Treatment as Usual (TAU)). Methods A prospective, parallel design, open-label, randomised controlled trial comparing pain control in patient-directed self-management of pain (PaDSMaP) with nurse control of oral analgesia (TAU) after a TKR. Between July 2011 and March 2013, 144 self-medicating adults were recruited at a secondary care teaching hospital in the UK. TAU patients (n = 71) were given medications by a nurse after their TKR. PaDSMaP patients (n = 73) took oral medications for analgesia and co-morbidities after two 20 min training sessions reinforced with four booklets. Primary outcome was pain (100 mm visual analogue scale (VAS)) at 3 days following TKR surgery or at discharge (whichever came soonest). Seven patients did not undergo surgery for reasons unrelated to the study and were excluded from the intention-to-treat (ITT) analysis. Results ITT analysis did not detect any significant differences between the two groups’ pain scores. A per protocol (but underpowered) analysis of the 60% of patients able to self-medicate found reduced pain compared to the TAU group at day 3/discharge, (VAS -9.9 mm, 95% CI -18.7, − 1.1). One patient in the self-medicating group over-medicated but suffered no harm. Conclusion Self-medicating patients did not have better (lower) pain scores compared to the nurse-managed patients following TKR. This cohort of patients were elderly with multiple co-morbidities and may not be the ideal target group for self-medication

    Proprioception deficiency in articular cartilage lesions of the knee

    Get PDF
    Purpose: The purpose of this study is to investigate the proprioceptive function of patients with isolated articular cartilage lesions of the knee as compared to normal controls. Methods: The Cartilage group consisted of eight subjects with radiologically and arthroscopically confirmed, isolated, unilateral, articular cartilage lesions of the knee (Outerbridge grade III or IV). They were compared to 50 normal controls. Knee proprioception was assessed by dynamic postural stabilometry using the Biodex Balance SD System. Patient-reported outcome measures (PROMs) were used to evaluate all subjects. Results: Proprioception of the injured knee of the Cartilage group was significantly poorer compared to that of the control group (p < 0.001). A significant proprioceptive deficit also was observed when the uninjured knees of the Cartilage group were compared to those in the Control group (p = 0.003). There was no significant proprioceptive difference between the injured and the contra-lateral uninjured knee of the Cartilage group (p = 0.116). A significant correlation was found between the proprioception measurements of the injured and uninjured knee of the Cartilage group (r = 0.76, p = 0.030). A significant difference was observed in all PROMs (p < 0.001) between the Cartilage and Control groups. Conclusions: Patients with isolated articular cartilage lesions of the knee had a significant proprioceptive deficit as compared to normal controls. The deficiency was profound and even affected the proprioceptive function of the contra-lateral uninjured knee. This study has shown that articular cartilage lesions have a major influence on knee proprioception. However, it remains uncertain as to whether a proprioceptive deficit leads to osteoarthritis or is a consequence of it

    Measurement of exclusive pion pair production in proton–proton collisions at √s=7 TeV with the ATLAS detector

    Get PDF
    The exclusive production of pion pairs in the process pp→ ppπ+π- has been measured at s=7TeV with the ATLAS detector at the LHC, using 80μb-1 of low-luminosity data. The pion pairs were detected in the ATLAS central detector while outgoing protons were measured in the forward ATLAS ALFA detector system. This represents the first use of proton tagging to measure an exclusive hadronic final state at the LHC. A cross-section measurement is performed in two kinematic regions defined by the proton momenta, the pion rapidities and transverse momenta, and the pion–pion invariant mass. Cross-section values of 4.8±1.0(stat)-0.2+0.3(syst)μb and 9±6(stat)-2+2(syst)μb are obtained in the two regions; they are compared with theoretical models and provide a demonstration of the feasibility of measurements of this type

    Search for non-resonant Higgs boson pair production in the 2b+2l+ETmiss final state in pp collisions at s = 13 TeV with the ATLAS detector

    Get PDF
    A search for non-resonant Higgs boson pair (HH) production is presented, in which one of the Higgs bosons decays to a b-quark pair (bb ̄) and the other decays to WW*, ZZ*, or τ+τ−, with in each case a final state with l+l−+ neutrinos (l = e, μ). The analysis targets separately the gluon-gluon fusion and vector boson fusion production modes. Data recorded by the ATLAS detector in proton-proton collisions at a centre-of-mass energy of 13 TeV at the Large Hadron Collider, corresponding to an integrated luminosity of 140 fb−1, are used in this analysis. Events are selected to have exactly two b-tagged jets and two leptons with opposite electric charge and missing transverse momentum in the final state. These events are classified using multivariate analysis algorithms to separate the HH events from other Standard Model processes. No evidence of the signal is found. The observed (expected) upper limit on the cross-section for non-resonant Higgs boson pair production is determined to be 9.7 (16.2) times the Standard Model prediction at 95% confidence level. The Higgs boson self-interaction coupling parameter κλ and the quadrilinear coupling parameter κ2V are each separately constrained by this analysis to be within the ranges [−6.2, 13.3] and [−0.17, 2.4], respectively, at 95% confidence level, when all other parameters are fixed

    Search for resonant WZ production in the fully leptonic final state in proton–proton collisions at √s=13 TeV with the ATLAS detector

    Get PDF
    A search for a WZ resonance, in the fully leptonic final state (electrons or muons), is performed using 139&nbsp;fb - 1 of data collected at a centre-of-mass energy of 13&nbsp;TeV by the ATLAS detector at the Large Hadron Collider. The results are interpreted in terms of a singly charged Higgs boson of the Georgi–Machacek model, produced by WZ fusion, and of a Heavy Vector Triplet, with the resonance produced by WZ fusion or the Drell–Yan process. No significant excess over the Standard Model prediction is observed and limits are set on the production cross-section times branching ratio as a function of the resonance mass for these processes

    Studies of new Higgs boson interactions through nonresonant HH production in the b¯bγγ fnal state in pp collisions at √s = 13 TeV with the ATLAS detector

    Get PDF
    A search for nonresonant Higgs boson pair production in the b ¯bγγ fnal state is performed using 140 fb−1 of proton-proton collisions at a centre-of-mass energy of 13 TeV recorded by the ATLAS detector at the CERN Large Hadron Collider. This analysis supersedes and expands upon the previous nonresonant ATLAS results in this fnal state based on the same data sample. The analysis strategy is optimised to probe anomalous values not only of the Higgs (H) boson self-coupling modifer κλ but also of the quartic HHV V (V = W, Z) coupling modifer κ2V . No signifcant excess above the expected background from Standard Model processes is observed. An observed upper limit µHH &lt; 4.0 is set at 95% confdence level on the Higgs boson pair production cross-section normalised to its Standard Model prediction. The 95% confdence intervals for the coupling modifers are −1.4 &lt; κλ &lt; 6.9 and −0.5 &lt; κ2V &lt; 2.7, assuming all other Higgs boson couplings except the one under study are fxed to the Standard Model predictions. The results are interpreted in the Standard Model efective feld theory and Higgs efective feld theory frameworks in terms of constraints on the couplings of anomalous Higgs boson (self-)interactions

    Measurement of the energy asymmetry in tt¯ j production at 13 TeV with the ATLAS experiment and interpretation in the SMEFT framework

    Get PDF
    A measurement of the energy asymmetry in jet-associated top-quark pair production is presented using 139fb-1 of data collected by the ATLAS detector at the Large Hadron Collider during pp collisions at s=13TeV. The observable measures the different probability of top and antitop quarks to have the higher energy as a function of the jet scattering angle with respect to the beam axis. The energy asymmetry is measured in the semileptonic tt¯ decay channel, and the hadronically decaying top quark must have transverse momentum above 350GeV. The results are corrected for detector effects to particle level in three bins of the scattering angle of the associated jet. The measurement agrees with the SM prediction at next-to-leading-order accuracy in quantum chromodynamics in all three bins. In the bin with the largest expected asymmetry, where the jet is emitted perpendicular to the beam, the energy asymmetry is measured to be - 0.043 ± 0.020 , in agreement with the SM prediction of - 0.037 ± 0.003. Interpreting this result in the framework of the Standard Model effective field theory (SMEFT), it is shown that the energy asymmetry is sensitive to the top-quark chirality in four-quark operators and is therefore a valuable new observable in global SMEFT fits

    Electron and photon energy calibration with the ATLAS detector using LHC Run 2 data

    Get PDF
    This paper presents the electron and photon energy calibration obtained with the ATLAS detector using 140 fb−1 of LHC proton-proton collision data recorded at root(s) = 13 TeV between 2015 and 2018. Methods for the measurement of electron and photon energies are outlined, along with the current knowledge of the passive material in front of the ATLAS electromagnetic calorimeter. The energy calibration steps are discussed in detail, with emphasis on the improvements introduced in this paper. The absolute energy scale is set using a large sample of Z-boson decays into electron-positron pairs, and its residual dependence on the electron energy is used for the first time to further constrain systematic uncertainties. The achieved calibration uncertainties are typically 0.05% for electrons from resonant Z-boson decays, 0.4% at ET tilde 10 GeV, and 0.3% at ET tilde 1 TeV; for photons at ET tilde 60 GeV, they are 0.2% on average. This is more than twice as precise as the previous calibration. The new energy calibration is validated using J/psi -&gt; ee and radiative Z-boson decays
    corecore