2,511 research outputs found
Tapered-amplified AR-coated laser diodes for Potassium and Rubidium atomic-physics experiments
We present a system of room-temperature extended-cavity grating-diode lasers
(ECDL) for production of light in the range 760-790nm. The extension of the
tuning range towards the blue is permitted by the weak feedback in the cavity:
the diodes are anti-reflection coated, and the grating has just 10%
reflectance. The light is then amplified using semiconductor tapered amplifiers
to give more than 400mW of power. The outputs are shown to be suitable for
atomic physics experiments with potassium (767nm), rubidium (780nm) or both, of
particular relevance to doubly-degenerate boson-fermion mixtures
Anomalous radio emission from dust in the Helix
A byproduct of experiments designed to map the CMB is the recent detection of
a new component of foreground Galactic emission. The anomalous foreground at ~
10--30 GHz, unexplained by traditional emission mechanisms, correlates with
100um dust emission. We report that in the Helix the emission at 31 GHz and
100um are well correlated, and exhibit similar features on sky images, which
are absent in H\beta. Upper limits on the 250 GHz continuum emission in the
Helix rule out cold grains as candidates for the 31 GHz emission, and provide
spectroscopic evidence for an excess at 31 GHz over bremsstrahlung. We estimate
that the 100um-correlated radio emission, presumably due to dust, accounts for
at least 20% of the 31 GHz emission in the Helix. This result strengthens
previous tentative interpretations of diffuse ISM spectra involving a new dust
emission mechanism at radio frequencies. Very small grains have not been
detected in the Helix, which hampers interpreting the new component in terms of
spinning dust. The observed iron depletion in the Helix favors considering the
identity of this new component to be magnetic dipole emission from hot
ferromagnetic grains. The reduced level of free-free continuum we report also
implies an electronic temperature of Te=4600\pm1200K for the free-free emitting
material, which is significantly lower than the temperature of 9500\pm500K
inferred from collisionally-excited lines (abridged).Comment: Accepted for publication in Ap
RESPOND â A patient-centred program to prevent secondary falls in older people presenting to the emergency department with a fall: Protocol for a multi-centre randomised controlled trial
Introduction: Participation in falls prevention activities by older people following presentation to the Emergency Department (ED) with a fall is suboptimal. This randomised controlled trial (RCT) will test the RESPOND program which is designed to improve older personsâ participation in falls prevention activities through delivery of patient-centred education and behaviour change strategies. Design and setting: An RCT at two tertiary referral EDs in Melbourne and Perth, Australia. Participants: Five-hundred and twenty eight community-dwelling people aged 60-90 years presenting to the ED with a fall and discharged home will be recruited. People who: require an interpreter or hands-on assistance to walk; live in residential aged care or >50 kilometres from the trial hospital; have terminal illness, cognitive impairment, documented aggressive behaviour or history of psychosis; are receiving palliative care; or are unable to use a telephone will be excluded. Methods: Participants will be randomly allocated to the RESPOND intervention or standard care control group. RESPOND incorporates: (1) home-based risk factor assessment; (2) education, coaching, goal setting, and follow-up telephone support for management of one or more of four risk factors with evidence of effective intervention; and (3) healthcare provider communication and community linkage delivered over six months. Primary outcomes are falls and fall injuries per-person-year. Discussion: RESPOND builds on prior falls prevention learnings and aims to help individuals make guided decisions about how they will manage their falls risk. Patient-centred models have been successfully trialled in chronic and cardiovascular disease however evidence to support this approach in falls prevention is limited. Trial registration. The protocol for this study is registered with the Australian New Zealand Clinical Trials Registry (ACTRN12614000336684)
Observation of double radiative capture on pionic hydrogen
We report the first observation of double radiative capture on pionic
hydrogen. The experiment was conducted at the TRIUMF cyclotron using the RMC
spectrometer, and detected --ray coincidences following stops
in liquid hydrogen. We found the branching ratio for double radiative capture
to be . The measured
branching ratio and angle-energy distributions support the theoretical
prediction of a dominant contribution from the
annihilation mechanism.Comment: 4 Pages, 4 Figures. accepted for publication in Phys. Rev. Let
RESPOND â A patient-centred programme to prevent secondary falls in older people presenting to the emergency department with a fall: Protocol for a mixed methods programme evaluation.
Background Programme evaluations conducted alongside randomised controlled trials (RCTs) have potential to enhance understanding of trial outcomes. This paper describes a multi-level programme evaluation to be conducted alongside an RCT of a falls prevention programme (RESPOND). Objectives 1) To conduct a process evaluation in order to identify the degree of implementation fidelity and associated barriers and facilitators. 2) To evaluate the primary intended impact of the programme: participation in fall prevention strategies, and the factors influencing participation. 3) To identify the factors influencing RESPOND RCT outcomes: falls, fall injuries and ED re-presentations. Methods/ Design Five hundred and twenty eight community-dwelling adults aged 60â90 years presenting to two EDs with a fall will be recruited and randomly assigned to the intervention or standard care group. All RESPOND participants and RESPOND clinicians will be included in the evaluation. A mixed methods design will be used and a programme logic model will frame the evaluation. Data will be sourced from interviews, focus groups, questionnaires, clinician case notes, recruitment records, participant-completed calendars, hospital administrative datasets, and audio-recordings of intervention contacts. Quantitative data will be analysed via descriptive and inferential statistics and qualitative data will be interpreted using thematic analysis. Discussion The RESPOND programme evaluation will provide information about contextual and influencing factors related to the RCT outcomes. The results will assist researchers, clinicians, and policy makers to make decisions about future falls prevention interventions. Insights gained are likely to be transferable to preventive health programmes for a range of chronic conditions
On the difference between type E and A OH/IR stars
The observed SEDs of a sample of 60 OH/IR stars are fitted using a radiative
transfer model of a dusty envelope. Among the whole sample, 21 stars have
reliable phase-lag distances while the others have less accurate distances.
L*-P,Mlr-P and Mlr-L* relations have been plotted for these stars. It is found
that type E (with emission feature at 10um and type A (with absorption feature
at 10um) OH/IR stars have different L*-P and Mlr-L* relations while both of
them follow a single Mlr-P relation. The type E stars are proven to be located
in the area without large scale dense interstellar medium while the type A
stars are located probably in dense interstellar medium. It is argued here that
this may indicate the two types of OH/IR stars have different chemical
composition or zero age main sequence mass and so evolve in different ways.
This conclusion has reinforced the argument by Chen et al.(2001) who reached a
similar conclusion from the galactic distribution of about 1000 OH/IR stars
with the IRAS low-resolution spectra (LRS).Comment: 6 pages, 9 figures, 2 table
Excited-state OH Mainline Masers in AU Geminorum and NML Cygni
Excited-state OH maser emission has previously been reported in the
circumstellar envelopes of only two evolved stars: the Mira star AU Geminorum
and the hypergiant NML Cygni. We present Very Large Array (VLA) observations of
the 1665, 1667, and excited-state 4750 MHz mainline OH transitions in AU Gem
and Expanded Very Large Array (EVLA) observations of the excited-state 6030 and
6035 MHz OH mainline transitions in NML Cyg. We detect masers in both mainline
transitions in AU Gem but no excited-state emission in either star. We conclude
that the excited-state OH emission in AU Gem is either a transient phenomenon
(such as for NML Cyg outlined below), or possibly an artifact in the data, and
that the excited state OH emission in NML Cyg was generated by an episode of
enhanced shock between the stellar mass-loss and an outflow of the Cyg OB2
association. With these single exceptions, it therefore appears that
excited-state OH emission indeed should not be predicted nor observable in
evolved stars as part of their normal structure or evolution.Comment: ApJ Letter, accepted, 4 pages, 2 figure
A single atom detector integrated on an atom chip: fabrication, characterization and application
We describe a robust and reliable fluorescence detector for single atoms that
is fully integrated into an atom chip. The detector allows spectrally and
spatially selective detection of atoms, reaching a single atom detection
efficiency of 66%. It consists of a tapered lensed single-mode fiber for
precise delivery of excitation light and a multi-mode fiber to collect the
fluorescence. The fibers are mounted in lithographically defined holding
structures on the atom chip. Neutral 87Rb atoms propagating freely in a
magnetic guide are detected and the noise of their fluorescence emission is
analyzed. The variance of the photon distribution allows to determine the
number of detected photons / atom and from there the atom detection efficiency.
The second order intensity correlation function of the fluorescence shows
near-perfect photon anti-bunching and signs of damped Rabi-oscillations. With
simple improvements one can boost the detection efficiency to > 95%.Comment: 24 pages, 11 figure
- âŚ