12 research outputs found
Mounting system for optical frequency reference cavities
A technique for reducing the vibration sensitivity of laser-stabilizing optical reference cavities is based upon an improved design and mounting method for the cavity, wherein the cavity is mounted vertically. It is suspended at one plane, around the spacer cylinder, equidistant from the mirror ends of the cavity. The suspension element is a collar of an extremely low thermal expansion coefficient material, which surrounds the spacer cylinder and contacts it uniformly. Once the collar has been properly located, it is cemented in place so that the spacer cylinder is uniformly supported and does not have to be squeezed at all. The collar also includes a number of cavities partially bored into its lower flat surface, around the axial bore. These cavities are support points, into which mounting base pins will be inserted. Hence the collar is supported at a minimum of three points
Systematic study of the Sr clock transition in an optical lattice
With ultracold Sr confined in a magic wavelength optical lattice, we
present the most precise study (2.8 Hz statistical uncertainty) to-date of the
- optical clock transition with a detailed analysis of
systematic shifts (20 Hz uncertainty) in the absolute frequency measurement of
429 228 004 229 867 Hz. The high resolution permits an investigation of the
optical lattice motional sideband structure. The local oscillator for this
optical atomic clock is a stable diode laser with its Hz-level linewidth
characterized across the optical spectrum using a femtosecond frequency comb.Comment: 4 pages, 4 figures, 1 tabl
Recommended from our members
Simple and Compact 1-Hz Laser System via an Improved Mounting Configuration of a Reference Cavity
We report an improved mounting configuration for a passive optical cavity used for laser frequency stabilization. The associated reduction of the vibration sensitivity of the effective cavity length has led to a simple and compact reference cavity system for laser stabilization at the level of 1 Hz linewidt
Recommended from our members
Simple and Compact Hz-Level Linewidth Laser System via Improved Mounting Configuration of a Reference Cavity
We report a simple, robust 1-Hz linewidth laser system enabled by an improved mounting strategy for optical reference cavities used for laser frequency stabilization
Recommended from our members
Contribution of Thermal Noise to Frequency Stability of Rigid Optical Cavity via Hertz-Linewidth Lasers
We perform detailed studies of state-of-the-art laser stabilization to high finesse optical cavities, revealing fundamental mechanical thermal noise-related length fluctuations. We compare the frequency noise of lasers tightly locked to the resonances of a variety of rigid Fabry-Perot cavities of differing lengths and mirror substrate materials. The results are in agreement with the theoretical model proposed in K. Numata, A. Kemery, and J. Camp [Phys. Rev. Lett. 93, 250602 (2004)]. The results presented here on the fundamental limits of FP references will impact planning and construction of next generation ultrastable optical cavities
Recommended from our members
Subfemtosecond Timing Jitter between Two Independent, Actively Synchronized, Mode-Locked Lasers
With the implementation of a fast-bandwidth servo, along with improved laser construction and associated better passive stability, we have achieved subfemtosecond relative timing jitter between two independent, actively synchronized, mode-locked Ti:sapphire lasers. Timing jitter of 0.58 fs is obtained with a 160-Hz observation bandwidth over several seconds. Within a 2-MHz observation bandwidth, the timing jitter is 1.75 fs. Excellent repeatability and rapid speed in setting an arbitrary time delay between two pulses are also demonstrated
Sources, size distribution, and downwind grounding of aerosols from Mount Etna.
The number concentrations and size distributions of aerosol particles >0.3 mm diameter were measured at the summit of Mount Etna and up to 10 km downwind from the degassing vents during July and August 2004. Aerosol number concentrations reached in excess of 9 106 L1 at summit vents, compared to 4–8 104 L1 in background air. Number concentrations of intermediate size particles were higher in emissions from the Northeast crater compared to other summit crater vents, and chemical composition measurements showed that Northeast crater aerosols contained a higher mineral cation content compared to those from Voragine or Bocca Nuova, attributed to Strombolian or gas puffing activity within the vent. Downwind from the summit the airborne plume was located using zenith sky ultraviolet spectroscopy. Simultaneous measurements indicated a coincidence of elevated ground level aerosol concentrations with overhead SO2, demonstrating rapid downward mixing of the plume onto the lower flanks of the volcano under certain meteorological conditions. At downwind sites the ground level particle number concentrations were elevated in all size fractions, notably in the 2.0–7.5 mm size range. These findings are relevant for assessing human health hazard and suggest that aerosol size distribution measurements may aid volcanic risk management